Cylinder sensor with IO-Link
MK59xx
29
After the Back to Box reset, the sensor suspends communication and measurement operation until the
voltage is interrupted. The IO-Link data storage is not triggered.
We recommend documenting your own settings in the chapter Factory setting before carrying
out a reset.
Parameter setting:
u
Select [Parameters] > [Setup].
u
Execute command: [Application reset] or [Back-to-Box].
u
Disconnect and reconnect the power supply.
w
The device carries out a reboot.
9.11 Identification
9.11.1 Device information
Unalterable device information is stored on the unit. This includes:
•
Product name
•
Product family
•
Manufacturer
•
Manufacturer ID
•
Device ID
•
Serial number
•
Hardware / firmware revision
•
Description
In addition, further freely definable tags with a maximum length of 32 characters can be assigned to
the unit via the IO-Link interface using suitable parameter setting software. This includes:
•
application-specific tag
•
function tag
•
location tag
Read/edit device information:
u
Select [Identification].
u
Read device information or edit editable parameters.
9.11.2 Optical localisation
The sensor can be located remotely in the system via the IO-Link interface.
When using the command, both switching status LEDs will flash yellow.
u
Select [Identification].
u
Execute command: [Locator Start].
u
To end the flashing process: Execute command: [Locator Stop].