background image

CR3145

mobileIoT gateway

12

Object

Index

Subindex

Type

Default

Description

Power manage-
ment – time to
sleep

0x3333

0x08

U8
wo

Time in seconds until switching to sleep
mode.

The unit only changes to sleep mode if
clamp 15 is set to low and no CAN message
is present at the corresponding CAN inter-
face.

A CAN message can wake the unit from
sleep mode.

Depending on the device design, a level
change at clamp 15 or the detection of a
certain acceleration force can wake the unit
from sleep mode.

With this setting, CAN messages are sent if
clamp 15 is set to high.

Power manage-
ment – sleep tim-
er status

0x3333

0x29

U8
ro

0: sleep timer deactivated

1: sleep timer activated

The object can be read if clamp 15 is set to
high.

Power manage-
ment – shutdown
delay time

0x3333

0x32

U16
rw

Delay time in seconds

After detecting the ignition input (clamp 15)
and the CAN off state, the unit continues to
operate for the specified time and then goes
to sleep mode.

Power manage-
ment – cyclic
wake-up time

0x3333

0x35

U32
rw

Time in seconds

After the specified time period in sleep
mode, the unit automatically wakes up and
changes to standard mode.

This function is only active with a value > 0.

Power manage-
ment – accel.
wake-up force

0x3333

0x36

R32
rw

Force in g

If the accelerometer detects an acceleration
force greater than this value, the unit wakes
up and changes to standard mode.

This function is only active with a value > 0.

Power manage-
ment - CAN
sleep time

0x3333

0x41

U32
rw

Time in milliseconds

If the unit does not receive any CAN mes-
sages within the specified time period, it
changes to sleep mode.

This function is only active with a value > 0.

4.8 Device status

The unit can send this data via the CAN interface. The configuration is made via the following objects:

Object

Index

Subindex

Type

Default

Description

DeviceMode

0x4001

0x02

U8
rw

Bit 0: compatibility mode with unit CR3114
(1 s cycle)

Bit 1: forward device status via CAN bus
(1 s cycle)

Bit 2: forward complete GNSS data via CAN
bus (1 s cycle)

Bit 3: forward input/output data via CAN bus
(1 s cycle)

Bit 4: forward acceleration and gyroscope
data via CAN bus (100 ms cycle)

Status BaseID

0x4005

0x05

U16

0x200

COB ID start address for device status
transmission (1s cycle)

All data available in the respective device mode are sent via the CAN1 interface.

Summary of Contents for mobileIoT CR3145

Page 1: ...Operating instructions mobileIoT gateway CR3145 11365922 00 03 2021 GB...

Page 2: ...vigation satellite system 9 4 6 1 Automatically send GNSS data to the mobileIoT platform 11 4 7 Energy management 11 4 8 Device status 12 4 9 Compatibility mode 13 5 Installation 15 5 1 Mounting the a...

Page 3: ...ctions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings us...

Page 4: ...e If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caus...

Page 5: ...The unit enables wireless transfer of CAN data of a vehicle or machine according to the GSM and UMTS standards GPRS EDGE and HSPA are supported It is also possible to receive and transmit GNSS positi...

Page 6: ...rk with the best transmission speed and automatically switches to it The mobile radio interface supports bidirectional data exchange in the mobile network 4 2 eSIM card The unit is equipped with an em...

Page 7: ...Raw value of the analogue input measure ment Volt No filtering applied Analogue input 2 0x546F 0x15 R32 ro Pin 5 of the 14 pin Micro Timer II connector Raw value of the analogue input measure ment Vo...

Page 8: ...t byte Length bytes Type Object IO BaseID 0x00 0 4 R32 IO clamp 30 voltage 4 4 R32 IO clamp 15 voltage IO BaseID 0x01 0 4 R32 Analogue input 1 4 2 S32 IO device temperature 4 5 Accelerometers and gyro...

Page 9: ...CAN messages COB ID Start byte Length bytes Type Object Movement BaseID 0x00 0 4 R32 Acceleration X axis 4 4 R32 Acceleration Y axis Movement BaseID 0x01 0 4 R32 Acceleration Z axis 4 4 R32 Gyroscope...

Page 10: ...ference point before logging the position The flag remains on the written value until the position has been recorded It is then re set to 0 The unit can send this data via the CAN interface The config...

Page 11: ...his time has elapsed the logged file is closed and trans mitted to the server Set this value to 0 to deactivate the period All data available in the respective device mode are sent via the CAN1 interf...

Page 12: ...eriod in sleep mode the unit automatically wakes up and changes to standard mode This function is only active with a value 0 Power manage ment accel wake up force 0x3333 0x36 R32 rw Force in g If the...

Page 13: ...1 mobileIoT server TCP connection active 3 1 U8 Current network mode 4 2 U16 State machine error code 6 1 U8 Current connection mode 0x00 cloud logging mode 0x01 reserved 0x02 real time mode 0x03 IoT...

Page 14: ...em result 8 fatal error 9 initialisation 10 Internet connection active 11 mobileIoT server TCP connection active 3 1 U8 File transfer receive indication 4 1 U8 File transfer transmit command 5 1 U8 SM...

Page 15: ...safety will be impaired 74 Fig 1 Holes for mounting u Use 2 M5x30 cylinder head bolts to fix the unit on an even surface Tightening torque 2 2 Nm 5 1 Mounting the antennas u When mounting the antennas...

Page 16: ...1 5 analogue input 2 6 analogue input 3 7 digital output 8 digital output clamp 15 input ignition signal 9 factory setting 2 input 10 Not connected 11 Not connected 12 Not connected 13 CAN1_H CAN int...

Page 17: ...e operating status of the active connections The different colours are displayed according to priority from 5 low to 1 high If several operating states are active at the same time the STATUS LED alway...

Page 18: ...ata transfer in real time mode STATUS ON Initialisation after power on STATUS ON A configuration update is carried out via the ifm mobileI oT data portal STATUS ON A remote firmware update is carried...

Page 19: ...tivated the unit an mobileIoT data contract will be concluded After successful registration and activation the unit establishes a connection to the ifm mobileIoT data portal and enables bidirectional...

Page 20: ...e is restored All recorded data and settings are deleted The factory configuration is retained To carry out the factory reset via the CAN interface CANopen software e g maintenance tool and a communic...

Page 21: ...fm in case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the devic...

Page 22: ...rtal that processes applies the data mobileIoT platform The complete cloud solution including backend mobileIoT server infrastructure frontend for the machine management portal mobileIoT suite and dat...