10.2 Functional test of the safety light grids
Check the proper function of the safety light grids before work starts�
For the functional test an opaque test object has to be used�
1
2
►
Interrupt the light beams with the test object� First of all in the centre (1) and
then close to the active and the passive element (2)�
►
Make sure that the red LED on the active element is continuously lit during the
interruption of the light beams�
Observe the notes on maintenance of the safety light grids → 14
Maintenance, repair and disposal�
Notes on set-up → 17.1 Check list.