8.2 Menu explanation
OU2 Output function for OUT2:
• Analogue signal for the current system pressure: 4���20 mA [I] or 20���4 mA [InEG]�
tCOF Teaching zero-point calibration�
tASP Teaching analogue start point for the system pressure: set value at which 4 mA
are output (20 mA on [OU2] = [InEG])�
tAEP Teaching analogue end point for the system pressure: set value at which 20 mA
are output (4 mA on [OU2] = [InEG])�
EF
Extended functions / Opening menu level 2�
Uni
Standard unit of measurement for the system pressure�
SELd
Display mode:
• Pressure in the unit set in [Uni]�
• Pressure in % of the set scaling of the analogue output�
ASP Analogue start point for the system pressure: measured value at which 4 mA are
output (20 mA on [OU2] = [InEG])�
AEP Analogue end point for the system pressure: measured value at which 20 mA are
output (4 mA on [OU2] = [InEG])�
HI
Maximum value memory for the system pressure�
LO
Minimum value memory for the system pressure�
COF Zero point calibration�
dAA
Damping for the analogue output�
diS
Update rate and orientation of the display�
rES
Restore the factory setting�