3 Functions and features
The unit monitors the system pressure of machines and plants
Applications
Type of pressure: relative pressure
Order no.
Measuring range
Permissible
overpressure
Bursting pressure
bar
PSI
bar
PSI
bar
PSI
PN004A
-110
-14,5145
75
1 087
150
2 175
PN006A
02,5
036,3
20
290
50
725
PN007A
01
014,5
10
145
30
450
PN009A
-10
-14,50
10
145
30
450
MPa = bar ÷ 10 / kPa = bar × 100
Analogue measuring range for PN004A = 010 bar
Avoid static and dynamic overpressure exceeding the given overload
pressure by taking appropriate measures
The indicated bursting pressure must not be exceeded
Even if the bursting pressure is exceeded only for a short time, the unit
may be destroyed NOTE: Risk of injury!
4 Function
4.1 Processing of the measured signals
• The unit displays the current system pressure
• It generates 2 output signals according to the parameter setting
OUT1
Switching signal for system pressure limit value
OUT2
Analogue signal 420 mA / 010 V