5.1 Installation location
►
Install the unit downstream of the cold dryer�
►
Install the unit near the load�
►
The unit can be installed downstream of a maintenance unit�
►
If oil is used for the loads: install the unit upstream of the oiler�
5.2 Installation position
5.2.1 Inlet and outlet pipe lengths
Structures in the pipe, bends, valves, reducing pieces and the like affect the
function of the unit�
►
Adhere to the distances between sensor and interference:
Interference
Distance to the sensor
changes to the pipe diameter
10 x pipe diameter
90° elbow
10 x pipe diameter
two 90° elbows, one plane
15 x pipe diameter
two 90° elbows, two planes
25 x pipe diameter
valve, slide
40 x pipe diameter
Shut-off valves and control devices are not allowed directly in front of the
unit�