SDGx50
Flow meter compressed air
8
5 Function
•
The unit detects flow based on the calorimetric measuring principle.
•
As additional process values the unit also detects the medium temperature and the pressure.
•
The unit has an IO-Link interface.
•
The unit displays the current process values.
•
The unit has many self-diagnostic options.
•
A simulation mode allows simplified set-up of the sensor.
•
The unit generates two output signals according to the parameter setting.
5.1 Output OUT1 selection options
•
Switching signal flow
•
Switching signal temperature
•
Switching signal pressure
•
Switching signal totaliser
•
Pulse signal totaliser
•
IO-Link
•
OFF (output switched to high impedance)
5.2 Output OUT2 selection options
•
Switching signal flow
•
Switching signal temperature
•
Switching signal pressure
•
Switching signal totaliser
•
Analogue signal flow
•
Analogue signal temperature
•
Analogue signal pressure
•
Input for external totaliser reset
•
OFF (output switched to high impedance)
5.3 Switching output
OUTx changes its switching status if it is above or below the set switching limits. Hysteresis or window
function can be selected.