Adjust the flush volume by moving the float upwards for
less and downwards for more. See fig. .
Each increment is 1 litre, adjustable from 2-5 litres, or
from 2-3 litres for model 6832.
To adjust the flush volume for the long flush, remove the
unit by turning it a quarter turn clockwise and then lifting
straight up as in fig. .
Adjust the flush volume by moving the float upwards for
less and downwards for more. See fig. .
Flush volume
settings are marked out on the float rod.
Adjustable from
3-8 litres, or 3-6 litres for model 6832.
To have the same flush volume on both sides of the flush
button, cut away the catch on the lever arm as shown in
fig. .
Optional accessory for single flushing:
Flush button
kit for same flush volume on both sides, white.
Ifö no.
Z98310 RSK no. 7925059.
This modification can be changed by turning the bridge
so that the rear catch is installed facing forwards
.
10
Flush button
Ifö Sign WC units are supplied with one of two flush
button options:
- Polished chrome flush button with 4/2 litre flush.
Ifö no. Z98303. RSK 7925053
- White flush button with same 4 litre flush on both sides.
Ifö no.
Z98310. RSK no. 7925059
Options include:
Raised chrome or red flush button.
The red flush button is suitable for physically and
mentally disabled users.
Removal of flush button
and cistern cover
Remove the flush button, cover mounting and cover as
illustrated in images , - .
13
15 19
If the WC unit runs – first check that the outlet valve’s
valve ring is not damaged. If it is, replace the valve ring,
Ifö no. Z96765, as illustrated in images - .
Then check that the inlet valve closes correctly. If it does
not, replace the inlet valve, Ifö no. Z96766, as illustrated
in images - .
The lever arm to the inlet float is normally installed
on the lower float setting for optimum water flow. This
setting can handle a water pressure of 10 bars. In the
event of the WC unit running at high water pressures,
the lever arm can be moved to the upper setting and
then handles a maximum water pressure of a 12 bars.
See image .
22
20
23 25
26
Servicing armatures
Set flush water volume
This WC-unit is test approved according to NT VVS 120
for use at full flush down to 3.5 litres. Also approved
according to EN 997 class 1 type 4 for full flushing 4 litres.
All WC units are factory set at delivery for a flushing
volume of 6 litres for full flushing and 3 litres for half. Two
litres is sufficient for flushing out urine and single sheets
of paper. If necessary, adjustment can be carried out for
other flushing volumes
First shut off the water supply. To adjust the flush volume
for the short flush, remove the bridge as shown in fig.
, .
Adjusting the flushing volume
21
20
28
29
Reinstalling
Maintenance advice and cleaning
Reinstall in reverse order. The screws for the cistern
mounting must be tightened alternately to a maximum
torque of 2.5 Nm as illustrated in image . The cover
screw must be tightened to a maximum torque of
1.0 Nm as illustrated in image .
32
34
30
29
Normal WC units, bidets and wash basins have a glazed
surface. Glazed surfaces are easy to keep clean and
are resistant against most chemicals. Clean regularly to
prevent cleaning problems. Use normal cleaning agents.
“Clean regularly to prevent cleaning problems. However,
avoid using cleaning agents on the flush button, instead,
use hot water and soap and wipe dry with a cloth”.
This is because cleaning agents for porcelain are not
intended for chrome parts/plastics and can risk cracking
the flush button if used frequently.
Cleaning utensils, which contain abrasive agents, such
as wire wool and green scouring pads, must not be
used. Strong acids, e.g. hydrochloric acid and sulphuric
acid and strong alkalines, e.g. caustic soda should not
be used. Dripping taps and running WC units must be
repaired immediately.
For repair or to purchase spare parts, contact a
plumbing contractor or plumbing centre. They can be
found in the Yellow Pages.
In houses that are unheated during the winter, the WC
unit’s flush cistern must be drained and dried out. Pour
3-4 decilitres of anti-freeze into the water trap and cover
the water mirror with cooking oil or cling film to prevent
evaporation.
Ifö Sign 6893
You get more free floor space with the WC unit for wall
installation. It facilitates cleaning the bathroom. Installa-
tion kit supplied.
Ifö WC fixtures are available for wall reinforcement.
Ifö no. 98910
Summary of Contents for 6832
Page 25: ...25 10 11 12 1 2 13 14 9...
Page 26: ...26 16 17 2 1 1 20 21 18 19 15...
Page 27: ...22 23 27 24 25 2 liter 5 liter 2 liter 3 liter Max 12 bar Max 10 bar 26 27 6832...
Page 28: ...28 30 31 Max 2 5 Nm 1 3 2 4 32 1 2 28 3 liter 8 liter 3 liter 6 liter 29 6832...
Page 29: ...33 Max 1 0 Nm 34 29 36 35 6893 6894 6893 6894...