POC2502 Series User Manual
338
The page includes the following fields:
Object
Description
•
Mode
Allows user to enable or disable per port PD Alive Check function. By default, all
ports are disabled.
•
Ping PD IP Address
This column allows user to set PoE device IP address for system making ping to the
PoE device. Please note that the PD’s IP address must be set to the same network
segment with the PoE Switch.
•
Interval Time (10~300s)
This column allows user to set how long system should issue a ping request to PD
for detecting whether PD is alive or dead. Interval time range is from 10 seconds to
300 seconds.
•
Retry Count (1~5)
This column allows user to set the number of times system retries ping to PD.
For example, if we set count 2, it means that if system retries ping to the PD and the
PD doesn’t response continuously, the PoE port will be reset.
•
Action
Allows user to set which action will be applied if the PD is without any response. The
POC2502 PoC Switch offers the following 3 actions:
PD Reboot:
It means system will reset the PoE port that is connected to the
PD.
PD Reboot & Alarm:
It means system will reset the PoE port and issue an
alarm message via Syslog, SMTP.
Alarm:
It means system will issue an alarm message via Syslog, SMTP.
•
Reboot Time (30~180s)
This column allows user to set the PoE device rebooting time as there are so many
kinds of PoE devices on the market and they have a different rebooting time. The
PD Alive-check is not a defining standard, so the PoE device on the market doesn’t
report reboot done information to the PoE Switch. Thus, user has to make sure how
long the PD will take to finish booting, and then set the time value to this column.
System is going to check the PD again according to the reboot time. If you are not
sure of the precise booting time, we suggest you set it longer.
Buttons
: Click to apply changes.
Summary of Contents for POC2502 Series
Page 1: ...1 POC2502 Series User Manual P N 1073045 REV B ISS 18MAY22...
Page 4: ...POC2502 Series User Manual 1...
Page 142: ...POC2502 Series User Manual 139 VLAN ID 3 Port 4 5 Untagged Port 6 7 Tagged Port 1 3 Excluded...
Page 283: ...POC2502 Series User Manual 280 Figure 4 10 7 IP based ACE Page Screenshot...
Page 347: ...POC2502 Series User Manual 344 No packet loss will occur...