5
Providing you follow the recommended ventilation requirements you will:
Increase the life of the freezer.
Minimise the risk of condensation on the outside of the freezer.
Minimise the running costs.
Minimise operating noises caused by vibration.
Levelling
Once the refrigerator is positioned in its final location, it can be leveled using the adjustable feet at the front
of the freezer until they are firmly placed on the floor. Correctly leveling the freezer will stop any rocking or
vibration and keep the door aligned which helps the freezer run reliably and efficiently.
Door Fitting
The freezer door can be fitted to open to either the left or the right depending on the location. The appliance
must be tilted and supported in order to carry this out. It is therefore advisable to get some help during this
procedure. Take care when fitting and tightening screws.
Tools required:
Phillips style screwdriver / Flat bladed screwdriver / Hexagonal spanner
1. Tilt the unit slightly towards the rear and prop it securely. Two people are required to tilt the unit during the
door reversal process.
2. Remove the 2 screw covers first, then undo the screws underneath.
3. Remove the 2 screws on the back.
4. Lift the top cover away from the fridge.
5. Remove the three screws, then remove the upper hinge that hold the door in place. Lift the door and place
it on a padded surface to prevent it from scratching.
6. Swap the bottom bushing and bottom bushing cap of the upper door. The bottom bushing key must be in
the correct position to allow it to be inserted correctly.
7. Remove the lower screws, hinge bracket and adjustable feet from the unit bottom
8. Remove the screw-type adjustable feet from another side of the unit bottom and transfer it to the
corresponding position on the opposite side of the unit bottom.
9. Reattach the two lower screws, hinge bracket and adjustable feet to the opposite side of the unit bottom.
Loosely secure.
10. Carefully set the upper door back into place. Ensure the freezer door is aligned horizontally and vertically
so that the seals are closed on all sides before finally tightening the top hinge. Insert the hinge bracket and
screw it to the top of the unit.
11. Use a spanner to tighten it if necessary.
12. Put the top cover back and fix it in place with the screws.
13. With the door closed, check that the door is aligned horizontally and vertically and that the seals are
closed on all sides before finally tightening the bottom hinge. Re-adjust the levelling feet as needed.