Door seal should be cleaned solely with clean water without any cleansing agents and it should be
thoroughly dried.
The seal cannot get into contact with oily substances or grease!
Control whether door close properly during maintenance procedures.
Test: place a sheet of paper between the seal and the casing and close the door. The paper
should pose a tangible resistance during an attempt to pull it out.
Elements of device can corrode when improper used and maintenance. To avoid that please
follow the rules:
• Do not allow contact of the surface of the device with substances containing chlorine and / or baking
soda in different varieties, which destroy the protective layer and components of the device (also
includes various stainless steel)
During maintenance services it is necessary to pay attention not to damage the data place of the device
Fig.15 (p.24), which contains signi
fi
cant information for servicing organs and waste removal companies.
6. SERVICE
6.1. Fault identi
fi
cation and repair
In case of any dif
fi
culties during actuation of the device or during its exploitation, please return to these chapters in this
manual, which explain the performed operation. This aims to ensure that the device is properly operated. If you still
experience dif
fi
culties, the following hints will help you solve the problem.
The device is not working... – Make sure that:
• The device is connected to the supply network
• Voltage and frequency in the network are compliant with those recommended by the producer 230V/50Hz
• The main switch is on
• Thermostat is on (This concerns the Igloo thermostat – If only two spots are visible on the display – turn on the
thermostat)
Water leakage from below the device or into the inside of the chamber:
• Check whether the device is properly levelled
• Check the patency of out
fl
ow pipes
• Empty the condenser tray or container
• Check whether there is not too much ice in the rail and on the condenser – defrost when necessary
The device is operating, but the lighting is off...– Make sure that:
• Lighting switch is turned on
• Fluorescent lamp or starting switch of the device are not burnt
The device does not reach the proper temperature, the lighting is on...– Make sure that:
• Lighting switch is turned on
• Temperature setting on the thermostat is properly set
• Thermostat works properly
• The condenser is clean, if necessary – clean the condenser
• Ambient temperature does not exceed 25ºC
• Enough time has passed for products to be cooled
• Ventilation holes of the device are not blocked
Fig.14 Changing the
fl
uorescent lamp
1 – Fluorescent lamp handle
2 – Fluorescent lamp
3 – Casing of
fl
uorescent lamp and
starting switch
4 – Starting switch of
fl
uorescent lamp
3
4
2
1