Pastry Display Cases
It is recommended to make a break in the operation
once a month
in order to clean the interior, naturally defrost
the evaporator and clean the condenser
It is essential to keep the condenser of the device clean. Dirt may hinder the heat exchange, causing mainly an
increase in electric energy consumption and may cause damage of the compressor. In order to clean the
condenser it is necessary to unscrew the sheet metal screws and pull the wind brace out of catch by lifting it up.
Clean condenser lamellas with help of soft brush or paint brush. If the condenser is extremely dirty (blocking of
lamellas) it is indicated to use vacuum cleaner or compressed nitrogen to suck / blow the dirt from between
lamellas.
The seller shall not be held responsible for any condenser damages in the case of non-
observance of condenser cleaning instructions.
Elements of equipment can corrode as result of improper use and maintenance.
To
prevent damage: Do not allow contact with substances containing chlorine and/ or
baking soda in different varieties, which destroy the protective layer and components of
the equipment (this also includes various stainless steel cleaners).
6. SERVICE
6.1. Faults identification and repair
In case of any difficulties during actuation of the equipment or during its operation, please return to the chapters in
this manual, which explain the performed operation. This aims to ensure the equipment is properly operated. If you
still experience difficulties, the following might help you solve the problems.
The equipment is not working... – Make sure that:
• The equipment is connected to the power supply.
• Voltage and frequency are compliant with those recommended by the manufacturer, 115V/60Hz.
Figure 6 Cleaning the condenser