background image

 

REFRIGERATION LTD 

 

Pastry Display Cases

 

| www.igloorefrigeration.com

 

 

1 UNLOADING 

The unit should be transported in vertical position and properly secured and packed.    

2 PROPERTIES OF THE UNIT 

 

 

 

2.1. Purpose 

“C3URP” series display cases are universal cooling devices that are aimed to display and are used for short-term 
storage for confectionery goods (such as cakes, cookies, desserts… etc.) in temperature b1ºC and +4ºC 
with ambient temperature b15ºC and +25ºC and relative air humidity up to 60%, depending on the 
environment and the location of the unit. 

2.2. Description of the unit   

“C3URP” series display cases have a dynamic cooling system. All units are equipped with automatic condensate 
evaporation and automatic defrosting. The electronic thermostat cooperates module to monitor and send signals 
when the temperature inside the equipment gets too low or too high. They can be supplied with self-contained or 
remote compressors. Glass shelves fixed on the frame make the exhibitive part of display cases. The height and 
angle of the shelves are adjustable. These display cases use energy-saving LED lighting.  Our equipment is 
manufactured in accordance to modern technologies and has all certificates required by law. 
 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The description in this box signifies important information for user security and for 
proper operation of the device. 

Summary of Contents for C3URHP

Page 1: ...Pastry Display Cases Models C3URP series C3URLP C3URHP C3URP Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LTD...

Page 2: ...ure regulation 7 5 MAINTENANCE 11 5 1 Cleaning and maintenance 11 6 SERVICE 12 6 1 Faults identification and repair 12 6 2 Service 14 List of Figures Figure 1 C3URP 2 Shelves 4 Figure 2 Placing the ho...

Page 3: ...ption of the unit C3URP series display cases have a dynamic cooling system All units are equipped with automatic condensate evaporation and automatic defrosting The electronic thermostat cooperates mo...

Page 4: ...ss 8 Shelf hook for glass shelf height angle adjustable 9 Serial plate 10 Control panel thermostat switches 11 Condensate container 12 Condenser cover DO NOT BLOCK air louver 13 Leveling legs 2 3 Tech...

Page 5: ...GLOO will not warranty any equipment that is connected to an extension cord or adapter plug The equipment may be turned on after confirmation of the fire protection efficiency with results of measures...

Page 6: ...e on metal elements should be removed only with extraction naphtha not applicable to items made of plastic Do not use other organic solvents When cleaning the unit do not use water jet The unit should...

Page 7: ...ensure proper conditions for the stored products do not load the shelves completely Ensure even load of shelves and not to exceed the maximum load The first filling of shelves should be performed afte...

Page 8: ...inside the equipment is displayed decimal places displayed after the comma Diode 6 On Off Switch Pressing this button alone for more than 3 sec switch On Off Pressing with other buttons pressed togeth...

Page 9: ...ccess to the latter is protected by password default 22 to prevent accidental or unauthorized modifications Accessing the type F parameters Press the SET button for more than 3 s if there are active a...

Page 10: ...n enabled by digital input 0 min 0 199 d6 freeze control temperature display during defrost 1 0 1 dd dripping time 2 min 0 15 d8 alarm bypass time after defrost 2 h 0 15 d9 defrost priority over compr...

Page 11: ...prevent moisture damage Door gaskets shelves and supports should be cleaned on a regular basis Fan blades and guards should be cleaned with a soft cloth 5 1 Cleaning and maintenance All maintenance se...

Page 12: ...be held responsible for any condenser damages in the case of non observance of condenser cleaning instructions Elements of equipment can corrode as result of improper use and maintenance To prevent d...

Page 13: ...ure sensor inside the chamber call authorized service L0 low temperature alarm lower than temperature range set within the equipment call authorized service HI high temperature alarm call authorized s...

Page 14: ...frigeration service Telephone number 416 663 3051 or toll free 1 888 408 8819 E mail service igloo400 com If after checking points described in chapter 6 1 Faults identification and repair and the equ...

Reviews: