4.  UNIT START UP 

 

Temperature of the cooled space and aggregate operating cycle may fluctuate. This depends on numerous factors, 
such as amount and temperature of products placed in the device and temperature of the surroundings.  The  
equipment should be placed in a dry and well-ventilated place, ensuring proper air exchange (distance between the 
wall and the equipment– min. 10cm), out of sunlight, kept far from heat sources and devices enforcing air flow 
(ceiling and portable ventilators, blow-in heaters). The equipment functions properly in a room, where temperature 
falls within appropriate climatic class. The operation of the equipment may worsen when operates outside the 
stated temperature range. 
 

Remarks and indications 

 

The display case has to be properly levelled, which will prevent noisy corking of 
the equipment and shall ensure proper water (condensate) outflow during 
defrosting. 

 

After transporting the equipment, wait about 2 hours before starting up the unit. 

 

To ensure proper conditions for the stored products, do not load the shelves 
completely. Ensure even load of shelves and not to exceed the maximum load. 

 

The first filling of shelves should be performed after the unit reached desired 
cooling temperature. This principle should also be observed after long pause in 
the operation. 

 

Do not block any ventilation holes, which would hamper circulation of the cooled 
air. It is also necessary to ensure proper airflow around the equipment. 

 

Keep the condenser clean. Impurities may lead to overheating of the compressor 
and may result in damage, which is not covered by warranty.  

 

Do not use electric devices inside the product storing chamber. 

 

Avoid unnecessary opening of the doors and leaving them open for a longer 
period of time. 

Figure 5 Control panel 
1 – Main switch (turns on/off the unit) 
2 – Light switch 
3 – Thermostat (temperature regulator) panel 
(Service details in Chapter 4 

 

Summary of Contents for CURHP2

Page 1: ...Pastry Display Cases Models CURP series CURLP CURHP CURP Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LTD...

Page 2: ...n 9 5 MAINTENANCE 12 5 1 Cleaning and maintenance 12 6 SERVICE 14 6 1 Faults identification and repair 14 6 2 Service 15 List of Figures Figure 1 CURP 4 Figure 2 placing the hooks in the frame 6 Figur...

Page 3: ...ption of the unit CURP series display cases have a dynamic cooling system All units are equipped with automatic condensate evaporation and automatic defrosting The electronic thermostat cooperates mod...

Page 4: ...egs 11 Serial plate 12 Control panel thermostat switches 2 3 Technical data Table 1 Technical data Model Voltage V Hz Ph Rated Current A Max shelf load lbs kg Weight lbs kg CURP2 115 60 1 8 max fuse 1...

Page 5: ...e protection efficiency with results of measures performed according to binding regulations 3 2 Unit Location Remove cardboard angles and protective foil Install the unit on a strong and leveled surfa...

Page 6: ...turning it on The unit should be cleaned with warm water not exceeding 40 C with a neutral detergent For washing and cleaning the equipment it is prohibited to use products containing chlorine and sod...

Page 7: ...ck and place it in the suitable position and at the suitable angle 7 Acorn nut of the screw 8 Silicon pad 9 Plasticizer pad 10 Screw 11 Inner frame 12 Display glass shelves of the frame 13 Bumper pads...

Page 8: ...quipment and shall ensure proper water condensate outflow during defrosting After transporting the equipment wait about 2 hours before starting up the unit To ensure proper conditions for the stored p...

Page 9: ...when the actuation of the ventilators is delayed by external disengagement or when another procedure is in progress Diode 3 Defrosting This symbol is visible when the defrosting function is activated...

Page 10: ...ter error manual Ed not active ON defrost ended by timeout On first defrost ended correctly CHt active ON dirty condenser alarm manual MODIFYING THE PARAMETERS Parameter navigation The operating param...

Page 11: ...st temperature set point 12 0 C 50 130 dP maximum defrost duration 30 min 1 199 d4 defrost when switching the instrument on 0 0 1 d5 defrost delay on power up or when enabled by digital input 0 min 0...

Page 12: ...with warm water and mild soap Make sure to cover the fan motor to prevent moisture damage Dore gaskets shelves and supports should be cleaned on a regular basis Fan blades and guards should be cleaned...

Page 13: ...d to use vacuum cleaner or compressed nitrogen to suck blow the dirt from between lamellas The seller shall not be held responsible for any condenser damages in the case of non observance of condenser...

Page 14: ...ty the condensate container The equipment does not reach the proper temperature the light is on Make sure that The main switch is on Temperature setting on the thermostat is properly set Thermostat wo...

Page 15: ...cuit This phenomenon constitutes a technical feature of cooling devices and does not signify equipment failure Steam precipitation on glasses is normal in the event of high relative air humidity excee...

Reviews: