REFRIGERATION LTD 

 

Pastry Display Cases

 

| www.igloorefrigeration.com

 

11 

 

Table 3 Table of easy compact parameters for CURP, CURLP and CURHP 

Par. 

Description 

Def. 

UOM. 

Min 

Max 

St 

set point 

°C 

r1 

r2 

PS 

password 

22 

99 

/2 

probe measurement stability 

15 

/4 

select probe displayed 

/5 

select °C/°F 

0(°C) 

1(°F) 

/6 

disable decimal point 

/C1 

probe 1 offset 

0.0 

°C 

-50.0 

50.0 

/C2 

probe 2 offset 

0.0 

°C 

-50.0 

50.0 

/C3 

probe 3 offset 

0.0 

°C 

-50.0 

50.0 

rd 

control differential 

3.0 

°C 

19.0 

r1 

minimum set point value 

0.0 

°C 

-50.0 

r2 

r2 

maximum set point value 

15.0 

°C 

r1 

99 

r3 

select direct/reverse operation 

r4 

night-time set point delta 

3.0 

°C 

-50 

50 

c0 

compressor and fan start delay on power-up 

min 

100 

c1 

minimum time between consecutive compressor starts 

min 

100 

c2 

minimum compressor off time 

min 

100 

c3 

minimum compressor on time 

min 

100 

c4 

compressor on time with duty setting 

50 

min 

100 

cc 

continuous cycle duration 

15 

c6 

temperature alarm bypass after continuous cycle 

15 

d0 

type of defrost 

dI 

interval between defrosts 

199 

dt 

end defrost temperature set point 

12.0 

°C 

-50 

130 

dP 

maximum defrost duration 

30 

min 

199 

d4 

defrost when switching the instrument on 

d5 

defrost delay on power-up or when enabled by digital input 

min 

199 

d6 

freeze control temperature display during defrost 

dd 

dripping time 

min 

15 

d8 

alarm bypass time after defrost 

15 

d9 

defrost priority over compressor  protectors 

d/ 

defrost probe reading (2) 

°C 

dC 

time base 

A0 

alarm and fan temperature differential 

2.0 

°C 

-20 

+20 

AL 

absolute/relative temperature for low temperature alarm 

0.0 

°C 

-50 

+99 

AH 

absolute/relative temperature for high temperature alarm 

0.0 

°C 

-50 

+99 

Ad 

temperature alarm delay 

min 

199 

A4 

3rd input configuration 

11 

A7 

digital input alarm delay 

min 

199 

A8 

enable alarm “Ed” (end  defrost  by timeout) 

AC 

set point dirty condenser alarm 

60 

°C 

-50 

250 

AE 

dirty condenser alarm differential temperature 

3.0 

°C 

0.1 

20 

Acd 

dirty condenser alarm delay 

min 

250 

F0 

enable evaporator fan control 

F1 

evaporator fan control set point 

5.0 

°C 

-50 

130 

F2 

stop evaporator fan if compressor off 

F3 

evaporator fan status during defrost 

Fd 

post-dripping time 

2.0 

min 

15 

H0 

serial address 

207 

H1 

AUX output configuration 

H2 

enable keypad 

H4 

disable buzzer 

 

Summary of Contents for CURP3

Page 1: ...Pastry Display Cases Models CURP series CURLP CURHP CURP Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LTD ...

Page 2: ...on 9 5 MAINTENANCE 12 5 1 Cleaning and maintenance 12 6 SERVICE 14 6 1 Faults identification and repair 14 6 2 Service 15 List of Figures Figure 1 CURP 4 Figure 2 placing the hooks in the frame 6 Figure 3 Hook height control 7 Figure 4 Assemble of glass elements 7 Figure 5 Control panel 8 Figure 6 Carel thermostat control panel 9 Figure 7 Manner of assembling pulling out the blow in and suction 12...

Page 3: ...iption of the unit CURP series display cases have a dynamic cooling system All units are equipped with automatic condensate evaporation and automatic defrosting The electronic thermostat cooperates module to monitor and send signals when the temperature inside the equipment gets too low or too high They can be supplied with self contained or remote compressors Glass shelves fixed on the frame make...

Page 4: ...legs 11 Serial plate 12 Control panel thermostat switches 2 3 Technical data Table 1 Technical data Model Voltage V Hz Ph Rated Current A Max shelf load lbs kg Weight lbs kg CURP2 115 60 1 8 max fuse 15 22 10 198 90 CURP3 115 60 1 8 max fuse 15 22 10 308 140 CURP4 115 60 1 12 max fuse 15 22 10 397 180 CURLP2 115 60 1 8 max fuse 15 22 10 CURLP3 115 60 1 8 max fuse 15 22 10 CURLP4 115 60 1 12 max fu...

Page 5: ...re protection efficiency with results of measures performed according to binding regulations 3 2 Unit Location Remove cardboard angles and protective foil Install the unit on a strong and leveled surface To ensure proper operation of the unit it must be leveled from front to back and left to right Unit may malfunction if improperly leveled Be sure there is sufficient ventilation around the entire ...

Page 6: ... turning it on The unit should be cleaned with warm water not exceeding 40 C with a neutral detergent For washing and cleaning the equipment it is prohibited to use products containing chlorine and sodium varieties which destroy the protective layer and components of the equipment Any residue of adhesives or silicone on metal elements should be removed only with extraction naphtha not applicable t...

Page 7: ...ack and place it in the suitable position and at the suitable angle 7 Acorn nut of the screw 8 Silicon pad 9 Plasticizer pad 10 Screw 11 Inner frame 12 Display glass shelves of the frame 13 Bumper pads 14 Inner surface Figure 4 Assemble of glass elements 1 Upper glass shelf 2 Front glass pane 3 Glass side 4 Front glass pane grip 5 Two sided angle for mounting of glass panes to CURP4 connecting the...

Page 8: ...equipment and shall ensure proper water condensate outflow during defrosting After transporting the equipment wait about 2 hours before starting up the unit To ensure proper conditions for the stored products do not load the shelves completely Ensure even load of shelves and not to exceed the maximum load The first filling of shelves should be performed after the unit reached desired cooling tempe...

Page 9: ...s when the actuation of the ventilators is delayed by external disengagement or when another procedure is in progress Diode 3 Defrosting This symbol is visible when the defrosting function is activated It blinks when the actuation is delayed by external disengagement or when another procedure is in progress Diode 4 Alarm This symbol is visible when the alarm is activated Diode 5 Current temperatur...

Page 10: ...eter error manual Ed not active ON defrost ended by timeout On first defrost ended correctly CHt active ON dirty condenser alarm manual MODIFYING THE PARAMETERS Parameter navigation The operating parameters modifiable using the keypad are divided into two types frequent type F and configuration type C Access to the latter is protected by password default 22 to prevent accidental or unauthorized mo...

Page 11: ...ost temperature set point 12 0 C 50 130 dP maximum defrost duration 30 min 1 199 d4 defrost when switching the instrument on 0 0 1 d5 defrost delay on power up or when enabled by digital input 0 min 0 199 d6 freeze control temperature display during defrost 1 0 1 dd dripping time 2 min 0 15 d8 alarm bypass time after defrost 2 h 0 15 d9 defrost priority over compressor protectors 0 0 1 d defrost p...

Page 12: ... with warm water and mild soap Make sure to cover the fan motor to prevent moisture damage Dore gaskets shelves and supports should be cleaned on a regular basis Fan blades and guards should be cleaned with a soft cloth 5 1 Cleaning and maintenance All maintenance services need to be performed after disconnecting the equipment from power supply Protect electrical components against any damage or w...

Page 13: ...ed to use vacuum cleaner or compressed nitrogen to suck blow the dirt from between lamellas The seller shall not be held responsible for any condenser damages in the case of non observance of condenser cleaning instructions This concerns CURP2 CURLP2 and CURHP2 Door seal should be cleaned solely with clean water without any cleansing agents and it should be thoroughly dried The seal cannot get int...

Page 14: ...pty the condensate container The equipment does not reach the proper temperature the light is on Make sure that The main switch is on Temperature setting on the thermostat is properly set Thermostat works properly The condenser is clean if necessary clean the condenser Ambient temperature does not exceed 25ºC Enough time has passed for products to be cooled Ventilation holes are not blocked Relati...

Page 15: ...rcuit This phenomenon constitutes a technical feature of cooling devices and does not signify equipment failure Steam precipitation on glasses is normal in the event of high relative air humidity exceeding 55 and does not require calling for service 6 2 Service IGLOO Refrigeration service Telephone number 416 663 3051 or toll free 1 888 408 8819 E mail service igloo400 com If after checking points...

Reviews: