Pastry Display Cases
6. SERVICE
6.1. Faults identification and repair
In case of any difficulties during actuation of the equipment or during its operation, please return to the chapters in
this manual, which explain the performed operation. This aims to ensure the equipment is properly operated. If you
still experience difficulties, the following will help you solve the problems.
The equipment is not working... – Make sure that:
• The
equipment is connected to the power supply.
• Voltage and frequency are compliant with those recommended by the
manufacturer, 115V/60Hz.
• The main switch is turned on
.
• Thermostat is
turned on.
The equipment is operating, but the light is off... – Make sure that:
•
Light switch is turned on.
•
Lamp or starting switch of the equipment are not burnt.
Water leakage from under the device
• Check whether the
equipment is properly levelled.
• Empty the condensate container
.
The equipment does not reach the proper temperature, the light is on... – Make sure that:
• The main switch is on
.
• Temperature setting on the thermostat is properly set
.
• Thermostat works
properly.
• The condenser is clean, if necessary
– clean the condenser.
• Ambient temperature does not exceed 25ºC
.
• Enough time has passed for products to be cooled
.
• Ventilation holes are not blocked
.
•
Relative air humidity no more than 55%.
Thermostat displays E0 or E1 or L0 or HI or EE or Ed or DF instead of temperature:
• E0
– failure of temperature sensor inside the chamber – call authorized service.
• L0
– low temperature alarm (lower than temperature range set within the equipment– call authorized service.
• HI
– high temperature alarm – call authorized service.
• EE
– internal defect of the regulator – call authorized service.
• Ed
– maximum defrosting time exceeded.
• DF
– defrosting in progress (this is not an alarm signal).
The equipment is working too loud...– Make sure that:
• The
equipment is standing stably and properly levelled.
•
Furniture adjoining the equipment does not vibrate when self-contained compressor is working.