3. PREPARING THE DEVICE FOR START UP
The unit must be properly installed and located in accordance with the installation
instructions before it is used.
3.1. Installation requirements
Always use a dedicated circuit with the amperage stated on the unit.
Plug into an outlet designed for the plug.
Do not overload the circuit.
Do not use extension cords.
Never use adapters.
Never plug in more than one unit per electric circuit.
If in doubt, call an electrician.
IGLOO will not warranty any equipment that is connected to an extension cord or
adapter plug.
The equipment may be turned on after confirmation of the fire protection efficiency
with results of measures performed according to binding regulations!
3.2. Unit Location
Remove cardboard angles and protective foil.
Install the unit on a strong and level surface.
To ensure proper operation the unit must be leveled from front to back and left to right.
Unit may malfunction if improperly leveled.
Be sure there is sufficient ventilation around the entire unit.
Select a location a way from heat and moisture generating equipment.
Avoid installation in a high ambient or humid location.
■
NEMA Plugs
IGLOO refrigeration uses this type of plug. If you do not have the right outlet, have a
certified electrician install the correct power source.
115/60/1
NEMA-5-15R
For models: JSCRP4/J2SCR4 &
JSCRP6/J2SCRP6
115/60/1
NEMA-5-20R
For models:
JSCRP8/J2SCR8