Refrigerated Pastry Display Case
| www.igloorefrigeration.com
11
SETTING THE DESIRED TEMPERATURE
- Press the set button
for 1 second leading value shall be displayed on the screen
- Increase or decrease the leading value by means of and , until the desired value shall be obtained;
- Press the set button
once again in order to confirm the new value of the setting point.
MANUAL INPUT OF THE DEFROSTING CYCLE
Defrosting shall be released in an automatic mode. It is possible to force defrosting at any moment by pressing and
holding the
defrost switch for minimum 5 seconds.
Table 2 Table of alarms and signals
alarm code
buzzer and alarm
relay
LED
alarm description
reset
E0
active
ON
probe 1 error= control
automatic
E1
active
ON
probe 2 error= defrost
automatic
E2
active
ON
probe 3 error=
condenser/product
automatic
EE
active
ON
unit parameter error
not possible
EF
active
ON
operating parameter error
manual
Ed
not active
ON
defrost ended by timeout
On first defrost ended correctly
CHt
active
ON
dirty condenser alarm
manual