background image

 

REFRIGERATION LTD 

 

Refrigerated Pastry Display Case

 

| www.igloorefrigeration.com

 

 

 

High ambient temperatures will cause the compressor to overwork. 

 

Humidity may cause rust, condensation around glass or stainless steel and decrease the efficiency of the 
unit. 
 

3.3. Connection and start-up 

 

To securely transport the equipment, the unit may be shipped partially disassembled. If the user received 
the unit partially disassembled, perform the following operations: 
1.

 

Screw the door handle. (Figure 3) 

2.

 

Install shelf grips in perforated frame strips. (Figure 4/2) The frame may be a rotating frame or fixed 
frame depending on the version of the unit.  

3.

 

Stick silicon glass protective pads on shelf grips. (Figure 4/4) 

4.

 

Place glass shelves on fixed grips. (Figure 4/1) 

“JOR” series display cases are equipped with 5 regulated round or rectangular glass shelves 
(depending on the option). The case with rotating frame is equipped with four upper glass 
shelves and a bottom mirror. 

 

The equipment should be cleaned right after unpacking and before turning it on. The unit should be cleaned 
with warm water not exceeding 40°C with a neutral detergent. For washing and cleaning the equipment, it 
is prohibited to use products containing chlorine and sodium varieties, which destroy the protective layer 
and components of the equipment! Any residue of adhesives or silicone on metal elements should be 
removed only with extraction naphtha (not applicable to items made of plastic). Do not use other organic 
solvents. 

When cleaning the unit, do not use water jet.  The unit should be cleaned with a 
moist cloth. 

 

After the  installation of the equipment at the destination location it should be left to 
rest for at least 2 hours before turning it on (for devices with built in compressor) to 
set the level of refrigerant in order to prevent problems with the start up. 
WARNING: Keep out the cooling circuit from damage! 

 

 

Turn on the main switch. (Figure 5/1) 

 

The temperature on thermostat control panel is PRE SET. (Figure 5/3) 

 

Turn on the light switch. (Figure 5/2) 

 

Turn on the frame rotating switch. (optional) 

Summary of Contents for JOR Series

Page 1: ...Pastry Display Cases Models JOR series JORTP JORWP JORPP Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LTD...

Page 2: ...ture regulation 9 5 MAINTENANCE 10 5 1 Cleaning and maintenance 10 6 SERVICE 15 6 1 Faults identification and repair 15 6 2 Service 16 List of Figures Figure 1 JOR series overview 4 Figure 2 Caster wh...

Page 3: ...tive air humidity not exceeding 60 depending on the environment and the location of the unit 2 2 Description of the unit JOR seriesdisplay casesare equipped with internal aggregate and forced air circ...

Page 4: ...feet 2 3 Technical data Table 1 Technical data Model Voltage V Hz Ph Rated Current A Max shelf load lbs kg Weight lbs kg JORPP Painted metal 115 60 1 8 max fuse 15 33 15 341 155 JORWP Wood finish 115...

Page 5: ...turned on after confirmation of the fire protection efficiency with results of measures performed according to binding regulations 3 2 Unit Location Remove cardboard angles and protective foil Install...

Page 6: ...helves and a bottom mirror The equipment should be cleaned right after unpacking and before turning it on The unit should be cleaned with warm water not exceeding 40 C with a neutral detergent For was...

Page 7: ...ll reactivate the rotation movement 1 Thermostat panel temperature regulator Service details in Chapter 4 2 Main switch turns on off the unit 2 Light switch 3 Rotation switch Figure 4 Install the door...

Page 8: ...he equipment min 10cm out of sunlight kept far from heat sources and devices enforcing air flow ceiling and portable ventilators blow in heaters The equipment functions properly in a room where temper...

Page 9: ...eating of the compressor and may result in damage which is not covered by warranty Do not use electric devices inside the product storing chamber After the door is closed negative pressure inside the...

Page 10: ...delayed by external disengagement or when another procedure is in progress Diode 4 Alarm This symbol is visible when the alarm is activated Diode 5 Current temperature inside the equipment is display...

Page 11: ...efrosting shall be released in an automatic mode It is possible to force defrosting at any moment by pressing and holding the defrost switch for minimum 5 seconds Table 2 Table of alarms and signals a...

Page 12: ...rily save the new value and display the parameter again Repeat the procedure for any other parameters that need to be modified Press the SET button for more than 3 s to permanently save the parameters...

Page 13: ...1 d5 defrost delay on power up or when enabled by digital input 0 min 0 199 d6 freeze control temperature display during defrost 1 0 1 dd dripping time 2 min 0 15 d8 alarm bypass time after defrost 1...

Page 14: ...use damage of the compressor In order to clean the condenser it is necessary to unscrew the sheet metal screws and pull the wind brace out of catch by lifting it up Clean condenser lamellas with help...

Page 15: ...The main switch is turned on Thermostat is turned on The equipment is operating but the light is off Make sure that Light switch is turned on Lamp or starting switch of the equipment is not burnt The...

Page 16: ...n on and off automatically Each compressor makes certain noises when operating These sounds are made by the aggregate engine and by cooling agent flowing through the circuit This noise constitutes a t...

Reviews: