COOLING CABINETS, MEDIUM-FREEZING AND FREEZING CABINETS WITH UPPER AGGREGATE (“AG” TYPE)
www.igloo.pl
1 – Main switch (turns on/ off the aggregate of the device)
2 - Turn the lighting switch inside the cabinet (version with
glazed doors)
3 – Thermostat panel (temperature regulator) (details of
service in Chapter No. 7 on p.19 and 20)
1 – Shelf
fi
xing grip
2 – Perforated frame strip
3 – Grid shelf
Fig. 2 Fixing the door grip
Fig. 5 Control panel
Fig. 3 Mounting perforated shelves
• Place the plug of the connecting cable directly in plug-in socket (it is forbidden to connect the device by means of
extension cords or dividers!)
• Turn on the main switch Fig.5/1 (p.14), which shall activate the thermostat and then main aggregate of the device.
• Set the temperature on the thermostat panel Fig.5/3 (p.14) (service details on p.19 or 20)
• Turn the lighting switch inside the cabinet Fig.5/2 (p.14) (concerns only glazed cabinets)
1 – Water (condensate) outlet hose
2 - Condensate tray (view from the front of the device)
3 – Foot used for levelling the device
Fig. 4 Condensate tray
4. EXPLOITATION
Temperature of cooled space and operating cycle of the aggregate may vary. It depends on numerous factors, such
as temperature of the surroundings and amount and temperature of products placed in the device. It is recommen-
ded to avoid unnecessary opening of the doors.
The device should be placed in a dry place, not insulated and well ventilated, ensuring proper air circulation (min. 10
cm distance between the wall and the device) far from sources of heat and devices forcing the air circulation (roof
ad mobile ventilators, blowing heaters). The device operates properly in an environment, where temperature falls
within proper climate class stated on the data plate. The operation of the device may worsen, when it will operate in
temperature higher or lower than the one determined in the stated temperature range.
After installation of the device at the destination place it should be left to rest for at least 2 hours before
turning it on (for devices with built in compressor) to set the level of refrigerant in order to prevent problems
with starting up the aggregate.
WARNING: Keep out the cooling circuit from damage!
1
2
3
1
2
3
3
1
2
Summary of Contents for OLA 1400.2 AG
Page 35: ...ru 35 AG www igloo pl 2 1 2 4 1 Igloo Carel 7 39 40 5 5 1...
Page 36: ...ru 36 AG www igloo pl AG 6 36 1 2 6 8 1 2 3 4 5 7 2 1 5 2 2 3 4 5 4 1...
Page 39: ...ru 39 AG www igloo pl 7 7 1 IGLOO 10 Igloo 3 3 2 www igloo pl 1 2 3 4 5 6 1 2 3 4 6 5...
Page 40: ...ru 40 AG www igloo pl 7 2 CAREL 11 Carel 1 2 4 4 5 1 5 1 www alfaco pl IGLOO 1 2 3 4 5...