6. SERVICE
6.1. Fault identi
fi
cation and repair
In case of any dif
fi
culties during actuation of the device or during its exploitation, please return to these chapters in this
manual, which explain the performed operation. This aims to ensure that the device is properly operated. If you still
experience dif
fi
culties, the following hints will help you solve the problem.
The device is not working... – Make sure that:
• The device is connected to the supply network
• Voltage and frequency in the network are compliant with those recommended by the producer, 230V/50Hz
• The main switch is turned on
• Thermostat is turned on (This concerns the Igloo thermostat – If only two spots are visible on the display – turn on
the thermostat)
Water leakage from below the device or into the inside of the chamber:
• Check whether the device is properly levelled
• Check the patency of out
fl
ow pipes
• Empty the condenser tray or container
• Check whether there is not too much ice in the rail and on the condenser – defrost when necessary
The device is operating, but the lighting is off...– Make sure that:
• Lighting switch is turned on
• Fluorescent lamp or starting switch of the device are not burnt
The device does not reach the proper temperature, the lighting is on...– Make sure that:
• The main switch is on
• Temperature setting on the thermostat is properly set
• Thermostat works properly
• The condenser is clean, if necessary – clean the condenser
• Ambient temperature does not exceed 25ºC
• Enough time has passed for products to be cooled
• Ventilation holes of the device are not blocked
(This concerns the “IGLOO” thermostat) thermostat displays C0 or C1 or C2 instead of displaying
temperature:
This situation shall occur, when one of temperature regulation sensors has been destroyed.
The following messages may be displayed in such case:
• C0 – temperature sensors inside the chamber are damaged – call authorized service
• C1 – failure of evaporator sensor - call authorized service
• C2 – failure of condenser alarm sensors (or failure of second evaporator sensor) – call authorized service
(This concerns the “CAREL” thermostat) Thermostat displays E0 or E1 or L0 or HI or EE or Ed or DF
instead of temperature:
• E0 – failure of temperature sensor inside the chamber – call authorized service
• E1 – failure of evaporator sensor – call authorized service
• L0 – low temperature alarm (lower than temperature range set within the device – call authorized service
• HI – high temperature alarm – call authorized service
• EE – internal defect of the regulator – call authorized service
• Ed – max. defrosting time exceeded
• DF – defrosting in progress (this is not an alarm signal)
(This concerns the “IGLOO” thermostat) The device is working, sound signalling is activated...
Make sure that:
• The condenser is clean, if necessary – clean the condenser
• Condenser ventilator is working properly
• Ambient temperature does not exceed 25ºC
The device is working too loud...– Make sure that:
• The device is standing stably
• Furniture adjoining the device do not vibrate when the cooling aggregate compressor is working
Summary of Contents for SYLWIA
Page 31: ...ru 31 Sylwia www igloo pl 3 1 7 35 36 2 3 4 10 2 4 1 Igloo Carel 7 35 36 2 3 1...
Page 32: ...ru 32 Sylwia www igloo pl 5 5 1 1 4 29 4 32 4 5 1 2 3 4 5 6 34 5 4 1 2 3...
Page 34: ...ru 34 Sylwia www igloo pl 6 2 6 1 Igloo 6 34 NS Sylwia 6...
Page 35: ...ru 35 Sylwia www igloo pl 7 7 1 IGLOO 7 Igloo 3 3 2 www igloo pl 1 2 3 4 5 6 2 1 3 4 6 5...
Page 36: ...ru 36 Sylwia www igloo pl 7 2 CAREL 8 Carel 1 2 4 4 5 1 5 1 www alfaco pl IGLOO 1 2 3 4 5...