background image

-6-

www.igmtools.com

Operating instructions EN

6.1.2 Control and gauge set up of the support table

The pre-set support table is perpendicular to the pressure 
plate. Place the support table on a mitre gauge (pic.2, 
gauge not supplied) to check proper alignment. If the 
table is not perpendicular, loosen the screw (1). Align 
the table according to the mitre gauge, tighten screw 
(1). Release screw (3) and set up the gauge (4) to „0“, then 
tighten again.

6.1.3 Adjusting the amount of applied glue The 
amount of glue is pre-set and should suit the 
majority of operations.

- If the amount of glue is not convenient. Prepare a test 

tape, warp up your machine and load the tape. Use the 

amount of glue adjustment knob to set the demanded 

quantity. Turning left adds and turning right decreases 

the amount of applied glue (pic.6) The scale displays the 

amount of glue.

- Caution: Do not turn the adjustment knob until the glue 

has reached operating temperature.

Too much glue overflows on the visible side of the tape. Not 

enough glue is not evenly applied along the whole width of 

the tape.

 

pic. 5a

 

pic. 5b

2

 

pic. 5c

 

Obr. 5

 

pic. 6

6.1.4 Thickness of tape

Set up thickness only when you have a softer or thinner 
tape than 1 mm. Otherwise, the pressure automatically 
adjusts to the tape. The thickness can be simply set by a 
turn of the knob (pic.7). 

pic. 7

6.1.5 Setting up tape length

- Measure the length of the banded edge and leave a 
bit more of the tape for final trimming.
- Apply enough pressure when trimming the edge, 
this will improve the finish.
 

Summary of Contents for 142-BR300

Page 1: ...choměřice Czech Republic EU Phone 420 220 950 910 E mail sales igmtools com Website www igmtools com Portable edgebander for ABS Operationg instructions 2022 07 12 142 BR300 IGM Portable Edgebander for ABS Manual EN v2 5 00 A4ob 142 BR300 www igmtools info PDF ONLINE ...

Page 2: ...y Co Ltd No 473 16 San Feng Road Houli District Taichung City Taiwan R O C 42156 We declare under our sole responsibility that the productdescribed in this manual is in conformity with the followingstandards EN ISO 12100 EN ISO 13857 EN 349 EN 953 EN 60204 1 EN ISO 11202 EN 55014 1 EN 55014 2 withthe provisions of Directives 2006 42 EC 2004 108 EC 2006 95 EC 2002 95 EC Signed Ivo Mlej Managing Dir...

Page 3: ...l clean and protect it from dirt and moisture in case of re selling pass the manual onto the new owner Any alterations or changes to the machine are prohibited Daily try out if the machine runs smoothly and check the function of protective covers before operating the machine Remove any malfunctions or deficiencies found on the machine as well as damaged protective cover The machine may only be use...

Page 4: ...y adhesive residues on the machine The Edgebander is designed for interior work Do NOT use the machine outdoors If you want to prevent debris falling into the glue pot Put on the lid If debris is already in the pot remove the glue turn on the machine for approximately 3 minutes the glue should come out easily now Re fill with glue again 1 Infeed tape guide 2 Temperature control 3 Set upof pressure...

Page 5: ...bander from the packaging and place on a flat surface Check for any apparent transport damages these could damage the machine or your health 5 2 Assembly 5 2 1 Mounting the corner guide Equip the corner guide only when banding inner corners or a radius smaller than 50 mm It would be getting in your way during other operations Place the corner guide on your edgebander according to pic 5 and tighten...

Page 6: ...achineandloadthetape Usethe amountofglueadjustmentknobtosetthedemanded quantity Turningleftaddsandturningrightdecreases theamountofappliedglue pic 6 Thescaledisplaysthe amountofglue Caution Donotturntheadjustmentknobuntiltheglue hasreachedoperatingtemperature Toomuchglueoverflowsonthevisiblesideofthetape Not enoughglueisnotevenlyappliedalongthewholewidthof thetape pic 5a pic 5b 2 pic 5c Obr 5 pic ...

Page 7: ...Heating indicator If the light is on the glue is being heated Operating indicator light lights up when the temperature is over 120 C 250 F you can speed up the heating by turning on the tape feeder Safe storage light When you turn off the heating this light will light up And will go out when the temperature in the glue pot goes below 60 C 140 F Now you can safely store your machine in 1 2 6 2 Befo...

Page 8: ...ces the worktable is available at IGMtools com as an optional accessory That way you can band edges like on a stationary edgebander 8 MAINTENANCE AND CONTROL 8 1 Maintenance after work Clean the machine properly after every operation and get rid of any glue on the edgebander with a proper tool or a dissolvent to prevent glue build up We recommend having the machine checked after 500 hours of work ...

Page 9: ...s twisted while banding The feed speed is slower than the feed of the tape Increase pressure on the workpiece The tape is slipping on the infeed roller Dust or debris on the infeed roller Clean the infeed roller The feed won t turn on The glue isn t melted enough the operating temperature hasn t been reached so far The motor can be turned on after reaching 12 C to ensure proper temperature for wor...

Page 10: ...IGM nástroje a stroje s r o Ke kopanině 560 Tuchoměřice 252 67 Czech Republic E U 420 220 950 910 www igmtools com 2022 IGM nástroje a stroje s r o ...

Reviews: