7. Troubleshooting guide 

Machine does not start or a breaker trips.

 

 

Possible Cause 

1. Power supply switched OFF or is faulty.

2. Wall fuse/circuit breaker is blown/tripped.

3. Faulty remote control.

4. Remote receiver is faulty.

5. Incorrectly wired motor connection.

6. On-board circuit breaker is tripped.

7. Wiring is open/has high resistance.

8. Faulty power switch.

9. Motor is at fault.

 

 

Possible Solution 

1. Ensure power supply is ON and has the correct voltage.

2. Ensure adequate circuit size; install inlet restrictor, replace weak breaker.

3. Replace batteries; ensure unobstructed line-of-sight and signal range.

4. Inspect receiver circuit board; replace if faulty.

5. Rewire or call certified service technician or electrician.

6. Allow motor to cool, improve ventilation, press reset button.

7. Check for broken wires or poor connections, repair as necessary.

8. Replace switch.

9. Test/repair/replace.

Excessive vibration or noise during operation. 

 

Possible Cause 

1. Loose component.

2. Loose or broken motor mount.

3. Motor fan hitting fan cover.

4. Bad motor bearings.

 

 

Possible Solution 

1. Inspect and tighten all bolts/nuts. 

2. Tighten or replace as needed.

3. Check fan and cover; replace as needed.

4. Rotate shaft manually, check for grinding or loose shaft, replace bearings 

if needed.

Loud, repetitive noise, or excessive vibration coming from

cyclone

 

 

Possible Cause 

1. Machine is on uneven surface.

2. Damaged/Unbalanced impeller.

3. Loose connections.

4. Impeller is loose.

5. Motor fan hitting fan cover.

 

 

 

Possible Solution 

1. Stabilize on a flat surface.

2. Inspect impeller for dents, bends, loose fins. Replace if needed.

3. Check and re-tighten all fasteners.

4. Replace the motor and impeller. 

5. Check fan and cover; replace as needed.

Dust cyclone does not adequately collect dust or chips;

poor performance.

 

 

Possible Cause 

1. Canister end cap is full. 

2. Filter is dirty.

3. Restricted duct line.

4. Suction route is too long or has too many sharp bends.

5. Wet lumber is clogging ducts. 

6. Leaks in the duct work or too many open ports.

7. Inadequate velocity in the main suction line.

8. Wrong size ducting/ports used.

 

 

 

Possible Solution 

1. Empty canister end cap.

2. Clean filter.

3. Clean inlet splitter.

4. Move machine closer to the point of suction, and rerun ducts to eliminate 

sharp bends.

5. Use lumber with less than 20% moisture content.

6. Repair all duct leaks and close any ports not being used.

7. Increase velocity by opening 1 or 2 more blast gates to different branch 

lines. 

8. Re-size and re-install ducts and fittings.

Sawdust being blown into the air from the dust cyclone. 

 

Possible Cause 

1. Band clamp or end cap is not secure.

2. Loose or damaged seals.

 

 

Possible Solution 

1. Re-install ensuring a tight fit.

2. Replace seals and gaskets.

Summary of Contents for Laguna PFlux3Tv2

Page 1: ...istributor IGM n stroje a stroje s r o Ke Kopanin 560 252 67 Tuchom ice Czech Republic EU Phone 420 220 950 910 E mail sales igmtools com Website www igmtools com 2022 04 04 151 PFlux3Tv2 LAGUNA Cyclo...

Page 2: ...2 www igmtools com...

Page 3: ...in the workshop If a procedure feels dangerous don t try it Figure out an alternative procedure that feels safer REMEMBER Your personal safety is your responsibility This machine was designed for cert...

Page 4: ...ace surrounding work area and non glare overhead lighting Keep the floor around the machine clean and free of scrap material oil and grease Keep visitors a safe distance from the work area Keep childr...

Page 5: ...ppliance must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or...

Page 6: ...ng or damaged parts to your dealer or distributor Prior to tool assembly and use read this manual thoroughly to familiarize yourself with proper assembly maintenance and safety procedures 5 2 General...

Page 7: ...d 6 5 16 OD18 2t flat washers Step 8 Secure the 3 upright support reinforcement plates using 12 5 16 3 4 hex bolts and 12 5 16 OD18 2t flat washers Step 9 With the help of another person lift the unit...

Page 8: ...otruding nut circled in red below It should be facing upwards when you place the bars on the floor Step 19 Ensure that the foot pedal bar is the correct side and slide the Foot pedal bar into the open...

Page 9: ...ply foam tape to the cone flange before attaching the drum lid Secure the Octagon drum lid to the cyclone funnel using 6 5 16 x 3 4 hex bolts 12 5 16 x 1 flat washers and 6 5 16 hex nuts Make sure to...

Page 10: ...side Otherwise this will cause for air leakage regardless of silicone being applied Step 36 Once completing the assembly keep the drum laying on its side to apply silicone not included to the inside o...

Page 11: ...ine off While the canister is cleaning the yellow LED light on the control panel will illuminate showing that it is in the process of cleaning There is a HEPA filter replacement indicator which is the...

Page 12: ...CT MACHINE FROM POWER REMOVING THE CANISTER FILTER 1 Release the spring loaded band clamp at the bottom of the canister filter and remove the plastic bag 2 While supporting the canister filter assembl...

Page 13: ...place bearings if needed Loud repetitive noise or excessive vibration coming from cyclone Possible Cause 1 Machine is on uneven surface 2 Damaged Unbalanced impeller 3 Loose connections 4 Impeller is...

Page 14: ...14 www igmtools com 8 POWER CONNECTIONS WIRING DIAGRAMS CONTROL PANEL POWER CONNECTIONS...

Page 15: ...15 www igmtools com AUTOCLEAN MOTOR SECONDARY JUNCTION BOX...

Page 16: ...16 www igmtools com 9 Parts breakdown Exploded Views 2021 10 14 X s I q...

Page 17: ...1 16D HEX NUT 5 16 4 16E PDCPF22201 16E DRUM CASTER 3 4 16U PDCPF22201 16U HEX BOLT 5 16 x 3 4 16 16F PDCPF22201 16F FLAT WASHER 5 16 xOD18x2t 32 16G PDCPF22201 16G HEX NUT 5 16 16 16H PDCPF22201 16HV...

Page 18: ...R ALARM 1 44 PDCPF22201 44 PHILIP HD BOLT M4 6mm 4 45 PDCPF22201 45 RUBBER HANDLE FOR DRUM INSERT 4 46 PDCPF22201 46 CONTROL PANDLE HANDLE 2 46A PDCPF22201 46A PHILIP HD BOLT M4 6mm 4 47 PDCPF22201 47...

Reviews: