background image

Installation 

D8-3_EN 

– V1.0 

8/14 

3.2.1 

Pin Assignment 

The connectors must be wired according to your application.  
 

Connector 

Pin 

Name 

Description 

Voltage limits 

X1 

V + 

Power supply 

24 V to 48 V 

V - 

Power supply ground 

0 V 

A + 

Motor A 

A - 

Motor A/ 

B + 

Motor B 

B - 

Motor B/ 

X2 

STEP + 

Motion input/Positive limit 

5 V to 24 V 

STEP - 

Motion input/Positive limit ground 

0 V 

DIR + 

Direction input/Negative limit 

5 V to 24 V 

DIR - 

Direction input/Negative limit ground 

0 V 

EN + 

Enable/Movement Start signal 

5 V to 24 V 

EN - 

Enable/Movement Start signal ground 

0 V 

Out+ 

Power supply status output „Error“ 

5 V up to 24 V 

Out- 

Output „Error“ 

Depended on OUT+ 

 

 

NOTE 

If different power supplies are used for the supply of the motor (terminal V+ and V-) and the supply of the signal transmitter 
(terminal STEP+, STEP-, DIR+, DIR- and EN+ and EN-), a ground potential equalisation of the power supplies must be 
performed 

 

3.2.2 

Connection Scheme Signal In/Output 

 
Enable signal „EN“  
 
 

 

 

Motion signal „STEP“ and „DIR“  

 
 

 

 

 
 

 

Summary of Contents for motion Plastics D8-3

Page 1: ...V1 0 1 14 igus motion Plastics dryve D8 3 Stepper Motor Control System Step Direction Loop Mode 1 60 rpm Manual V 1 0 Website MotorShop http www igus eu motorshop Videos Tutorials www igus eu dryve t...

Page 2: ...2 1 4 Environmental conditions 6 3 Installation 7 3 1 Mechanical Installation 7 3 2 Electrical Installation 7 3 2 1 Pin Assignment 8 3 2 2 Connection Scheme Signal In Output 8 3 3 Integration into Saf...

Page 3: ...sonal injury or damage to property resulting from misuse or unauthorised technical modification of the motor controller igus reserves the right to make changes and improvements to the product or the t...

Page 4: ...nt or property damage NOTE Safety instructions marked with NOTE indicate a potential hazardous situation Disregard of the notice may possibly result in property damage 1 5 Electromagnetic Compatibilit...

Page 5: ...dditional switches and sensors Simple control With the loop mode a continuous movement between 2 limit switches can be executed without the need for a master controller The movement is executed at a f...

Page 6: ...n 50 s Dissipation Loss Max 264 W Digital Inputs Outputs Galvanically Separated by Optocoupler Voltage supply output Out Max 30 V Current output Out Max 100 mA Boot up time 2 s Cable length Max 30 m L...

Page 7: ...stallation The motor controller is constructed for use with direct currents Every voltage mentioned in this manual can be regarded as direct current WARNING Risk of injury Make sure that an emergency...

Page 8: ...t Negative limit 5 V to 24 V 4 DIR Direction input Negative limit ground 0 V 5 EN Enable Movement Start signal 5 V to 24 V 6 EN Enable Movement Start signal ground 0 V 7 Out Power supply status output...

Page 9: ...urrent No voltage free status of the motor Switching off the enable signal EN Direct de energisation of the motor Uncontrolled coasting of the motor Motor could remain energised in a fault condition S...

Page 10: ...are available for configuring the motor control These can be used to preselect the emitted motor current during a movement the step mode the emitted current at standstill and the fixed motor speed in...

Page 11: ...1 3 Micro Stepping If the motor controller is used in Pulse Mode p 13 the desired micro step mode must be preselected by the combination of switch SW4 to SW6 and SW 8 By preselecting the micro steps p...

Page 12: ...FF OFF OFF OFF 4 1 5 Drive Mode The desired operating mode is set via switch SW8 Drive Mode SW8 Pulse Mode Step Direction ON Loop Mode Constant Speed OFF 4 2 Motor Direction For a proper operation it...

Page 13: ...e connected to the STEP input and the negative to DIR To start the continuous motion sequence a 5 V to 24 V signal must be applied to input EN After applying the signal a movement towards the positive...

Page 14: ...SET 1 Top Hat rail mounting clip with matching screw Connectors D8 CONNECTOR SET Complete set off all dryve D8 1 connector plugs 8 Service Customer service de dryve igus net 49 0 2203 9649 845 Technic...

Reviews: