3.3 

Integration into Safety Circuits 

The integration into a safety circuit must always be in accordance with the applicable regulations. 
 
The following options are available 

Measures 

Advantages 

Disadvantages 

Switching off the load supply voltage 

Direct de-energisation of the 
motor 

Uncontrolled coasting of the 
motor 

Switching off 

control signals “STEP“ and “DIR“ 

Generation of a braking torque 
by emitting a holding current 

No voltage-free status of the 
motor 

Switching off the enable signal "EN" 

Direct de-energisation of the 
motor 

Uncontrolled coasting of the 
motor. 

Motor could remain energised 
in a fault condition. 

Switching off the control signals at "STEP" and "DIR" 
and delayed switching off of the enable signal "EN" 

Generation of a braking torque 
by output of the holding current 

No direct de-energisation of the 
motor. 

Motor could remain energised 
in a fault condition. 

Switching off the control signals at "STEP" and "DIR" 
and delayed switching off of the load supply voltage  

Generation of a braking torque 
by emitting a holding current 
with subsequent de-
energisation of the motor 

No direct de-energisation of the 
motor.  

 

Initial Operation 

The following describes the initial operation, which makes the start easy. 
 
Connect the whole system according to 

Electromagnetic Compatibility

 (p. 4) 

 

Minimum equipment 

To control a motor with the D3 dryve, a minimum equipment has to be provided by the user: 

1. 

Power supply with 24 V up to 48 V and connecting cables 

2. 

Stepper motor with suitable cable 

3. 

Switches/signa generator/microcontroller/PLC 

 

 

 

WARNING! 

 

Fire hazard 

Faulty settings of the motor controller can lead to extremely high motor temperatures. 

 

 

NOTE 

A faulty connection can damage or destroy the motor controller. 

 
 
 

 

 

DANGER! 

 

Danger of falling load 

Never work under unsecured vertical axes and loads. 

Secure the axis or load against falling by a mechanical safety device or other approved safety method. 

Summary of Contents for motion Plastics dryve D7

Page 1: ...D7_EN V1 2 1 14 igus motion Plastics dryve D7 Step Direction Stepper Motor Control System Manual V 1 2 Website MotorShop http www igus eu motorshop Videos Tutorials www igus eu dryve tutorial...

Page 2: ...6 2 1 4 Environmental conditions 6 3 Installation 7 3 1 Mechanical Installation 7 3 2 Electrical Installation 7 3 2 1 Pin Assignment 8 3 2 2 Connection Scheme Signal In Output 8 3 3 Integration into...

Page 3: ...onal injury or damage to property resulting from misuse or unauthorised technical modification of the motor controller igus reserves the right to make changes and improvements to the product or the te...

Page 4: ...t or property damage NOTE Safety instructions marked with NOTE indicate a potential hazardous situation Disregard of the notice may possibly result in property damage 1 5 Electromagnetic Compatibility...

Page 5: ...of various additional switches and sensors Simple control With the JOG mode a pre selected speed can be started by simply applying a signal The rotational direction can be changed by connecting a seco...

Page 6: ...t frequency 2 Hz up to 1 MHz Step input signal width Min 250 ns Direction input signal width Min 50 s Dissipation Loss Max 144 W Digital Inputs Outputs Galvanically Separated by Optocoupler Boot up ti...

Page 7: ...tion The dryve D3 motor controller is constructed for use with direct currents Every voltage mentioned in this manual can be regarded as direct current WARNING Risk of injury Make sure that an emergen...

Page 8: ...EP Motion input ground 0 V DIR Motion input 5 V up to 24 V DIR Motion input ground 0 V EN Enable signal 5 V up to 24 V EN Enable signal ground 0 V NOTE If different power supplies are used for the sup...

Page 9: ...ld remain energised in a fault condition Switching off the control signals at STEP and DIR and delayed switching off of the load supply voltage Generation of a braking torque by emitting a holding cur...

Page 10: ...mmand is present the motor current set via switches SW1 to SW3 is reduced to 50 SW7 ON or 90 SW7 OFF at standstill The auto tuning function allows the motor controller to be optimally adapted to the c...

Page 11: ...be the identical If for example 200 micro steps per motor revolution are set in the motor controller but 400 micro steps per motor revolution are set in the master controller and the master controller...

Page 12: ...ode a 5 V to 24 V signal must be permanently applied to the EN input If a square wave signal is applied to the STEP input a clockwise motor step is executed with each negative signal edge To execute a...

Page 13: ...a 5 V to 24 V signal must be permanently applied to the EN input If a 5 V to 24 V signal is applied to the STEP input a clockwise rotation is executed at the pre set speed To execute a counter clockwi...

Page 14: ...SET 1 Top Hat rail mounting clip with matching screw Connectors D7 CONNECTOR SET Complete set off all dryve D7 connector plugs 8 Service Customer service de dryve igus net 49 0 2203 9649 845 Technical...

Reviews: