Status and Error Messages
The red and green LED are indicating different status and error states.
LED
Behaviour
Description
Green
Permanently on
Enable signal applied - motor energised
Green
Flashing
Enable signal not applied - motor not energised
Red
Permanently off
No error
Red
1x flashing, off; permanently repeating
Overcurrent or short circuit
Red
2x flashing, off; permanently repeating
Overvoltage at V±
Red
3x flashing, off; permanently repeating
Overtemperature motor control
Red
4x flashing, off; permanently repeating
Missing motor winding
Red
5x flashing, off; permanently repeating
Internal fault