BEFORE STARTING TO USE THE UNIT

 Important Safety Information

Please read the information in the instruction manual and any other litera-

ture included with the product before using the device. It is important to 

follow all instructions in this manual including Safety instructions. Failure 

to follow the instructions may result in potentially hazardous situation re-

sulting in serious injury.

• For type, dose, and regime of medication follow the instructions of your 

doctor or respiratory therapist.

• If you feel anything unusual during use, stop using the device immedi-

ately and consult your doctor.

• Clean and disinfect the nebulizer kit, mask, mouthpiece or nosepiece 

before using them for the first time after purchase.

• If the device has not been used for a long period of time, or if more than 

one person uses the same device, clean and disinfect the nebulizer kit, 

mask, mouthpiece or nosepiece before using them.

• Be sure to wash the parts after use, and ensure that they are thoroughly 

disinfected and dried, and stored in a clean location in a sealed bag.

• Do not store the nebulizer kit parts while there is moisture, medicine, 

cleaning solution or medication remaining inside.

• Do not use or store the device where it may be exposed to high humid-

ity, noxious fumes ,volatile substances, flammable gases, heat sources, 

 

corrosive fluids and gases.

• Do not cover the compressor with a blanket, pillow, towel, or any other 

type of cover during use. Do not block the ventilation slots. Never place 

the device where the ventilation slots may be obstructed during operation. 

Keep the air openings free of lint, hair and the like.

• Never place the device on a soft surface, such as a bed or couch, where 

the ventilation slots may be blocked.

• Do not block the air filter cover.

• Use fresh medication each time, always dispose of any remaining medi-

cation after use.

• Do not use in anesthetic or ventilator breathing circuits.

• Do not use attachments not recommended by the manufacturer.

• Do not operate unit in a backpack or carrying bag.

• Never plug ,unplug or handle the device with wet hands.

• The compressor and power cord are not waterproof. Do not spill water or 

Summary of Contents for iWind

Page 1: ...NEBULIZER SYSTEM compressor model iWind...

Page 2: ...COPD and other respiratory ailments in which an aerosolized medication is required during therapy Aerosol easily and quickly comes to both upper and lower respiratory tracks Before starting to use the...

Page 3: ...zer systems are used by the patients with acute respiratory diseases obstructive pulmonary disease chronic inflammatory processes in respiratory passages such as chronic bronchitis bronchial asthma in...

Page 4: ...hey are thoroughly disinfected and dried and stored in a clean location in a sealed bag Do not store the nebulizer kit parts while there is moisture medicine cleaning solution or medication remaining...

Page 5: ...ear chil dren or invalids or persons who cannot express their consent Do not use the device while sleeping or if drowsy Keep the device and accessories out of the reach of unsupervised in fants and ch...

Page 6: ...time and check that there are no problem In particular be sure to check the following That the nozzle or air tube are not damaged That the nozzle is not blocked That the compressor operates normally W...

Page 7: ...Air tube 6 Child mask 7 Power switch 8 Filter 9 Air outlet connector 10 Carrying handle space 11 Power cord 12 Power plug 13 Ventilation slot CARRYING OUT NEBULIZING THERAPY Assembling the Unit opera...

Page 8: ...down in medication cup Open the medicine cup cap and put the medicine from medicine vial into the medicine cup Close the medicine cup cap tightly Attach one end of the tube to the medicine cup Connec...

Page 9: ...more than rated time See instrument bottom panel for details Allow specified off period for instrument to cool before resuming use The nebulizer is made with high quality of plastic which is safe for...

Page 10: ...ocedure If so follow their recommendations To prevent possible risk of infection from contaminated medication cleaning of the nebulizer is recommended after each aerosol treatment Disinfecting is reco...

Page 11: ...ion after each use Clean the nebulizer kit before using for first time after purchase Compressor leaning With power switch in the OFF position unplug power from wall outlet plug Wipe outside of the co...

Page 12: ...e bottom panel The device is abnormally loud Air filter is covered or dirty Attach the air filter cover correctly The device is very hot ompressor are covered ventilation slots are blocked Do not cove...

Page 13: ...ne Note If the suggested remedy does not solve the problem do not try to repair the device Shut off the device for about 1 hour and then restart the machine If the problem persists contact your author...

Page 14: ...p Mouthpiece The specifications and the outer design are subject to change for im provement reasons without previous notice Electromagnetic compatibility This aerosol therapy unit is designed to meet...

Page 15: ...rectly connected to the public low voltage power sup ply network which is used to supply homes and buildings Voltage fluc tuations flicker IEC 61000 3 3 Complies Emissions RC CISPR 14 1 Complies Nebul...

Page 16: ...th the device and those parts subject to normal wear and tear The warranty is only valid upon presentation of the warranty card with purchase date and stamp of trade organization Should the unit be da...

Reviews: