Trouble phenomenon and probable cause
→
Remedy
5.4.5
Abnormality in exhaust gas temperature
(1)
Reduced exhaust gas
temperature
a) Faulty temperature sensor
b) Faulty fuel valve (stuck needles)
c) Faulty fuel oil system
a) Check the pyrometer and its
mounting conditions.
b) Replace fuel valves.
c) Quickly take necessary measure so
that the trouble will not reach
fuel valves.
(2)
Elevated exhaust gas temperature
a) Unsuitable load
b) Faulty cooling of suction air
c) Excessive suction resistance of
suction air
d) Application of back pressure
from exhaust system.
e) Malfunction of turbo charger.
f) Burning of exhaust valve.
a) Observe fuel injection pump rack
position and check load conditions.
b) Increase cooling water.
c) Inspect the air filter.
d) Check if protective food has been
removed from exhaust outlet.
e) Check if the turbo charger is normally
operating. (Refer to Section 5.4.4 (3))
f) Replace exhaust valve and valve seat.
Summary of Contents for NIIGATA MG(L)26HLX
Page 2: ......
Page 34: ......
Page 38: ......
Page 40: ......
Page 60: ......
Page 66: ......
Page 68: ......
Page 80: ......
Page 82: ......
Page 86: ......
Page 88: ......
Page 94: ......
Page 107: ......
Page 108: ......
Page 110: ......
Page 130: ......
Page 132: ......
Page 170: ......
Page 174: ......
Page 186: ......
Page 188: ......
Page 192: ......