INNOVATIVE HEARTH PRODUCTS • KITS AND ACCESSORIES • BLOWER KIT (MODEL FBK-250)
4
NOTE: DIAGRAMS AND ILLUSTRATIONS NOT TO SCALE
120 VAC BLACK
NEUTRAL WHITE
GROUND GREEN
SPEED CONTROL MODULE
Plug Blower into Module and
Module into Top Receptacle.
Tab intact
NEUTRAL SIDE
OF RECEPTACLE
If any of the original wire as supplied must be replaced, it must be
replaced with type AWM 105 degree C - 14 gauge wire.
Green ground screw
RECEPTACLE
Red
Black
JUNCTION BOX
HOT SIDE
OF RECEPTACLE
Field Wired
Factory Wired
BLOWER
120V, 60HZ, 1PH BLOWER CONTROL CIRCUIT WIRING
Blower Control Module
Control Knob
Module Securing Screw
VIEW B - MOUNTING CONTROL MODULE TO CABINET
Firebox Bottom Floor
Cabinet Bottom Panel
Wing Nut
Adjust Thermal Element Sensing Disk
to Touch Bottom of FireBox Floor
Module Cabinet Base Tab
Blower Control Module
Control Knob
Module Securing Screw
Firebox Bottom Floor
Cabinet Bottom Panel
Wing Nut
Adjust Thermal Element Sensing Disk To Touch
Bracket On Bottom Of FireBox Sub-Floor
Module Cabinet Base Tab
Firebox Sub-Floor
VIEW A - MOUNTING CONTROL MODULE TO CABINET
Figure 10
Figure 9
14.
Reinstall the bottom panel, louver assembly, access door, control
compartment door, facade or Barrier that was removed prior to op-
eration.
15.
Restore the electrical power to the unit.
16.
Start the fireplace by following the procedure indicated in the lighting
instructions section of the Installation and Operation Instructions
manual, supplied with the fireplace.
17.
Check the start up and shutdown, and the running operation of the
blower. Also check the variable speed feature of the speed control.
Direct-vent Units - The approximate blower start time is 15 minutes from
main burner startup. The approximate blower shut off time is 10 minutes
after main burner shut down.
B-Vent Units - The approximate blower start time is 20 minutes from
main burner startup. The approximate blower shut off time is 20
minutes after main burner shut down.
J-BOX WIRING
CAUTION
Ground lead must be connected to the green screw
located on the junction box. Failure to do so will
prevent the appliance from operating. The appli-
ance must be electrically grounded in accordance
with local codes or, in the absence of local codes,
the National Electrical Code, ANSI/NFPA 70—lat-
est edition (In Canada, the current CSA C22.1 Ca-
nadian Electrical Code).
Printed in U.S.A. © 2000 Innovative Hearth Products