background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

1

HeatFlo™ Kit

GENERAL INFORMATION

The HeatFlo™ system is designed to redirect the convective heat 

of the fireplace from the front of the unit, above the glass, to a 

location higher on the wall. The use of this kit allows for TV instal-

lations closer to the fireplace or in recessed wall cavities above 

the fireplace (see tables 1 and 2 on page 2).
When Installing this kit, reference the framing dimensions and 

follow the framing instructions shown on the fireplace installation 

Instructions. Follow all other installation requirements for the 

fireplace as detailed in the installation manual.

REFER TO INSTALLATION INSTRUCTIONS AND CARE AND 

OPERATIONS MANUAL (IICO) FOR FRAMING DETAILS BEFORE 

INSTALLING THIS KIT.

ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND 

OPERATION MANUAL PROVIDED WITH THE FIREPLACE APPLY 

TO THESE INSTRUCTIONS. 

INSTALLATION INSTRUCTIONS FOR HeatFlo™ Kit

FOR USE IN ASTRIA ALLUMEDLX60TEN, ALLUME60TEN AND SUPERIOR DRL4060TEN FIREPLACES

(This Kit is Compatible for One Sided or See-Thru Application)

HEARTH PRODUCTS 

KITS AND ACCESSORIES

900929-00 REV.  B  05/2019

HeatFlo™ Kit

Catalog 

Number

Model Number

Kit Name

F3780

HTFLO-LIN60

HeatFlo Kit

HeatFlo 

Collar

Gear 

Clamp

Plenum 

Bracket

Flex Pipe 

5” x 26” 

Heat 

Register

HeatFlo 

Register

Trim

TOOLS REQUIRED (not included)

Electric Drill/Driver Gun
Phillips Screwdriver Bits
5/16 Nut Driver
3/8 Nut Driver
Wood Screws

Kit Components

1 ea. Heat Register
1 ea. HeatFlo Register Trim
4 ea. 5” x 26” (compressed length) Flex Pipe
8 ea. Gear Clamp
4 ea. HeatFlo Collar
2 ea. Plenum Bracket
32 ea. Self Tapping Screws

 WARNING 

This kit must be installed by a qualified installer, 

service agency, or gas supplier at the time of the 

fireplace installation. These instructions must 

be used in conjunction with the installation and 

operation manual provided with the fireplace. 

INSTALLER: Leave this manual with the fireplace.

CONSUMER: Retain this manual for future 

reference.

IMPORTANT NOTICE 

HTFLO-LIN60 (HeatFlo) KIT IS REQUIRED IF INSTALLING A 

TV ABOVE THE FIREPLACE.

f i r e - p a r t s . c o m

Summary of Contents for HeatFlo Kit HTFLO-LIN60

Page 1: ...IA ALLUMEDLX60TEN ALLUME60TEN AND SUPERIOR DRL4060TEN FIREPLACES This Kit is Compatible for One Sided or See Thru Application HEARTH PRODUCTS KITS AND ACCESSORIES 900929 00 REV B 05 2019 HeatFlo Kit Catalog Number Model Number Kit Name F3780 HTFLO LIN60 HeatFlo Kit HeatFlo Collar Gear Clamp Plenum Bracket Flex Pipe 5 x 26 Heat Register HeatFlo Register Trim TOOLS REQUIRED not included Electric Dri...

Page 2: ... TV Installed Above Fireplace on a Recessed Wall Pocket A TV Above Fireplace Opening 18 458mm B Recess Depth Maximum 3 1 2 89mm C Heat Vent Opening Below Ceiling 6 153mm Television TV Fireplace Television TV 5 1 2 410 mm HeatFlo Register Opening 3 Min 77 mm 3 Min 77 mm 3 Min 77 mm 3 Min 77 mm B C A Wall Floor Ceiling Min 88 1 2 2 250 m Max 20 ft 6 096 m TVs should not be used in situations where t...

Page 3: ... To access the glass door securing latches first remove the screen barrier from fireplace 2 Lift the barrier to clear the bottom channel and swing the bottom of the barrier out Then lower the barrier to clear the top channel Place the barrier in a safe location for later re installation Figure 1 3 Detach the four 4 door latches on top of firebox Figure 2 4 Swing the top of the glass door away from...

Page 4: ...e nailing flanges to the framing studs Figure 7 HeatFlo Diverter Plate Covers HeatFlo Collar Remove 4 Screws HeatFlo Diverter Plate Cover Outlet Cover Plate Figure 3 Preparing Fireplace for HeatFlo Kit Installation Remove Fireboard Nailing Flange for recessed installation Remove Fireboard Nailing Flange Top Spacers for Recessed Installation Figure 4 Removing Fireboard Nailing Flanges and Fireboard...

Page 5: ...ges to Jack Stud Fireplace Top Spacers Rotate Heat Register and insert into framing opening 7 1 2 Framing opening Vertical Stud Plenum Bracket Installed Between flue connectors 80 1 2 2045 mm Metal Straps both sides not provided Figure 6 Installing Heat Register Recessed Wall Pocket Framing Shown 1 Min Clearance To Combustibles All Around Pipes 1 Clearance 3 1 2 6 Note Support straps need to be or...

Page 6: ...ure 9 Note DO NOT SLICE PIPES 7 With the flex pipe sections attached to the fireplace stretch the flex pipes enough to reach the heat register collar in place Note Flex pipe stretches up to 3 times its compressed length ie 26 long pipe will stretch to 78 maximum Note Minimumallowedlengthfromfloortobottomofheatvent opening is 88 1 2 maximum allowed length is 20 ft Note Maintain 1 min clearance to c...

Page 7: ...ce should be rated at a minimum continuous exposure to 300 ºF Finishing Around Opening with Gypsum Wallboard Gypsumwallboard drywall jointsadjacenttothefireplaceopening including the non combustible board on the appliance require special attention to minimize cracking When installing gypsum wallboard around the fireplace install the hole for the fireplace opening in a single wallboard sheet if pos...

Page 8: ...ny time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2018 Innovative Hearth Products LLC P N 900929 00 Rev B 05 2019 1769 East Lawrence Street Russellville AL 35654 fire parts com ...

Reviews: