Fireplace and Chimney Requirements

This appliance must only be installed in a zero clearance factory-built 

fireplace using 6” (152mm) stainless steel pipe extending from the 

insert’s flue into the chimney of the fireplace. For optimum safety and 

performance we recommend a full length stainless steel liner directly 

connected to the insert’s flue outlet.

This appliance must only be installed in a zero clearance factory-built 

fireplace that is structurally sound. Fireboxes or chimneys that have flaws, 

burnouts, or warping must be replaced or repaired prior to installation. 

Check with your fireplace manufacturer if any problems exist.

All convection vents and louvers must be left unmodified and unob-

structed.

This appliance can only be installed in the following brands of factory-built 

zero clearance fireplaces:  IHP, SUPERIOR, HEATILATOR, MAJESTIC, 

MARTIN, PREWAY, MARCO, TEMCO and FMI.

The fireplace cavity must be 36” (914 mm) in width, 21” (533 mm) in 

height and 14” (356 mm) in depth. Installation in larger size fireboxes 

of the same brands is permissible.

Installations into other brands of the same size is permissible only with 

approval from local building officials.

Modifications allowed to the factory-built fireplace are as follows:

 - Remove the damper

 - Remove the smoke shelf or smoke baffle

 - Remove ember catches

 - Remove viewing screen/curtain

 - Remove side and rear bricks

 - Remove the fire grate

 - Remove doors

The factory built chimney must be listed per UL 127 (US), and meet type 

HT requirements of UL 103 (US). Factory built fireplace chimneys tested 

to UL 127-1998, may be at the fireplace manufacturer’s option, tested to 

the same criteria as UL 103 HT requirements. If the chimney is not listed 

as meeting HT requirements, or if the factory built fireplace was tested 

prior to 1998, a full height listed chimney liner must be installed from 

the appliance flue collar to the chimney top. The liner must meet type 

HT requirements (2100ºF) per UL 1777 (US). The liner must be securely 

attached to the insert flue collar and the chimney top. To prevent room air 

passage to the chimney cavity of the fireplace, seal either the damper area 

around the chimney liner with high temperature sealant or the fireplace 

front with fiberglass batting.

INSTALLATION PROCEDURE - FACTORY-BUILT ZERO  

CLEARANCE FIREPLACES

FIREPLACE PRE-INSTALLATION PREPARATION

NOTE:  IHP RECOMMENDS PROFESSIONAL INSTALLATION BY 

A LICENSED AND BONDED INSTALLER. SEE YOUR DEALER FOR 

RECOMMENDATIONS. IMPROPER INSTALLATION OR MIS-USE 

WILL VOID YOUR WARRANTY AND CREATE A SERIOUS SAFETY 

HAZARD.

Remove any doors or screen materials from the fireplace opening. Re-

move the damper mechanism completely. Also remove grates or ember 

catches inside the fireplace hearth. If your fireplace is equipped with a 

smoke shelf or baffle and if it interferes with the installation it may be 

removed. Side and rear refractory may also be removed, if necessary, 

to facilitate installation. No modifications shall be done unless allowed 

on the previous list. Retain all removed parts, they must be reinstalled 

before the fireplace can be used in it’s original condition.

CLEARANCE TO COMBUSTIBLES

See “Required Clearances” on Page 8.

Install the two 3” (76 mm) long bolts (with the head up) through the nuts 

attached to the insert on the lower rear corner of each side. This will allow 

you to level the insert when placed into the fireplace.

Measure from the front of the top surround mount to the center of the 

flue. Determine if there is an alignment problem in connecting a liner 

from the chimney to the insert’s flue. If there is an alignment problem, 

connection can be made using a short piece of stainless flex or a stain-

less steel offset box (available from your dealer). Before installing the 

liner, make any attachment brackets or drill any holes in the liner, offset 

box, or insert. Once installed, it may be difficult or impossible to drill 

additional holes.

INSERT PRE-INSTALLATION PREPARATION

FACTORY BUILT FIREPLACE WARNING TAG

The fireplace must not be altered, except for the exceptions listed 
below. The permanent metal warning label provided must be attached 
to the back of the fireplace, stating that the fireplace may have been 
altered to accommodate the insert, and must be returned to original 
condition for use as a conventional fireplace. The following modifica-
tions of factory built fireplaces are permissible: removal of damper, 
removal of smoke shelf or baffle, removal of ember catches, removal 
of fire grate, removal of viewing screen/curtain, and removal of doors.

NOTE: Secure the tag using screws or nails to the fireplace. 

COUNTRY STOVES

03-1863

This fireplace has been altered to accommodate 

a fireplace insert and should be inspected

by a qualified person prior to re-use as a

conventional fireplace.

Summary of Contents for IronStrike Performer C210AGL

Page 1: ...uméro de la pièce 900980 01 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before installing and using your wood fireplace insert Failure to follow these instructions could result in property damage bodily injuryorevendeath Contactyourlocalbuildingorfireofficials to obtain a permit...

Page 2: ...ts 10 Installation Procedures Masonry Chimney 10 Positive Flue Connection 11 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fireplace Pre Installation Preparation 11 Insert Pre Installation Preparation 11 Chimney Liner Installation 13 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instruc...

Page 3: ... by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswithahotfire Iflargeaccumulations are occurring review your burning procedures 14 If a creosote fire should develop the fire department should be called immediately and then attempts should be made to control the fire until assistance arrives If a runaway fire should develop causing over heating of the insert the door a...

Page 4: ...ert is dependent upon a properly functioning chimney for optimum performance It is a high efficiency appliance that losesmuchlessheatupthechimneythanolderappliancesandfireplaces For this reason it is important to match the fireplace insert to the chimney The chimney has two functions 1 It draws combustion air into the appliance without air no fuel will burn and 2 It exhausts combustion by products...

Page 5: ...diately Other waste shall not be placedinthiscontainer Theclosedcontainerofashesshouldbeplacedon a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all the cinders have thoroughly cooled Ashes can ignite up to 72 h...

Page 6: ...MES RED REDUCE THE AMOUNT OF AIR ENTERING THE STOVE OR INSERT IMMEDIATELY BURN IN PERIOD PAINT CURING Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page 20 for a list of prohibited fuels Failure to burn proper fuels only will void the certification and the warranty of the appliance Dry seasoned wood is that which has been cut split and allowed to dry under a covered area where air is...

Page 7: ...install the two remaining boards where you originally installed the first two boards on each side of the baffle support and pushed against the rear of the unit The stainless steel support hanger should be centered left to right between the sets of baffle boards and placed as shown in Figure 4 3 Also included with the unit are two 15 x 10 x 1 thick baffle blan kets Install each blanket above the ba...

Page 8: ...the door opening of the unit Canada 18 450 mm minimum hearth extension on all stoves and inserts as measured from the door opening of the unit Minimum distance of floor protection to the side 8 200 mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada 2 J Maximum lintel depth without flue offset or smoke deflector NOTES Facing material that pr...

Page 9: ... asterisk indicates it is a value taken from Tables 2 and 3 FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate material kM x thickness alternate k value per inch of listed material TM of listed material kL material TL TM inches kM x TL 84 TM inches 35 x 375 84 156 inches 417 x 375 Answer Theminimumrequiredthick...

Page 10: ...er of the fireplace opening and push it back until the surround brackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug against thefireplaceface Thenwiththelocationselectedremovethesurround panels and level the fireplace insert with the leveling bolts using a 3 4 19 mm socket extensions to reach the bolt head and a ratchet 8 G...

Page 11: ...approved methods of achieving a positive flue connection See Figure 9 A qualified installer should evaluate the existing fireplace to determine the best method for achieving a positive flue connection between the vent pipe or liner and the existing fireplace chimney The most common method for achieving a positive flue connection in masonry fireplaces is to secure a seal off plate i e 22 gage sheet...

Page 12: ...Y BUILT ZERO CLEARANCE FIREPLACES FIREPLACE PRE INSTALLATION PREPARATION NOTE IHP RECOMMENDS PROFESSIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER SEE YOUR DEALER FOR RECOMMENDATIONS IMPROPER INSTALLATION OR MIS USE WILL VOID YOUR WARRANTY AND CREATE A SERIOUS SAFETY HAZARD Remove any doors or screen materials from the fireplace opening Re move the damper mechanism completely Also remove gr...

Page 13: ...t Part H5296 is available to fill the space between the insert and the hearth protection Install the brick and baffle as per Page 7 CHIMNEY LINER INSTALLATION INSTALLING THE INSERT POST INSTALLATION CHECKS Remove the existing chimney cap and install a stainless steel liner into the chimney if a special section has been used or drilled to attach to the insert it must be the bottom piece The next pi...

Page 14: ...hermometer can be a helpful tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor the temperature every 15 minutes or so until you become more familiar with your appliance Close the damper all the way down if you begin to reach 600 degrees as this is a si...

Page 15: ...o turn off continue to rotate the knob counterclockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch Blower Operation Guidelines While in auto operation mode the blower will turn off and on based on the temperature of the appliance Auto operation ensures there is suffi cient heat build up to warm the air being moved by the blower before the blower is turned on L...

Page 16: ...s locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few minutes to ignite the wood All IHP stoves and inserts are EPA tested for emissions at low burn with the air control completely closed Whether or not you should burn Your appliance with the air control...

Page 17: ...s are included with the graphite CAUTION Cleaning Glass Ensure appliance is cold prior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasivecleaners Donotcleanwithanymaterials which may scratch or otherwise damage the glass Scratches on the glass can develop into cracks or break Inspect the glass regularly If you detect a crack extinguish the fire and ...

Page 18: ...protective gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinstall Faceplate and Screws Reinstall faceplate onto door back and while holding the door assembly together flip the assembly back onto it s face Carefully reinstall the screws Be very careful not to ove...

Page 19: ...lass above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the baffle boards 2 Check the chimney for blockage due to creosote see Creosote section on Page 5 3 Check draft See POOR DRAFT section above WOOD BURNS 1 The draft control must be closed further TOO FAS...

Page 20: ...r requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Some people are more affected by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influen...

Page 21: ...Switch Bracket w hardware 18 H8082 Replacement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Switch Brushed Gold H8078 UHPII Blower Cage Snap Switch Brushed Nickel 29 H8064 Snap Switch w Gasket and Hardware 32 H8066 Control Switch Manual Off Automatic C210GL INSERT PARTS 33 71...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 33 34 36 36 45 46 47 37 37 35 40 44 40 38 38 38 41 38 38 38 41 38 38 42 38 38 38 38 42 38 38 39 39 43 39 39 REPLACEMENT PARTS MODEL C210TGL AND C210AGL ...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 REPLACEMENT PARTS MODEL C210TGL AND C210AGL Door Parts Blower Parts ...

Page 24: ...4 SURROUND TRIM THESE ARE NOT REQUIRED BUT AN OPTION 71021 WFT2640 B Black 26 3 4 x 40 71022 WFT2648 B Black 26 3 4 x 48 71025 WFT3040 B Black 30 3 4 x 40 71026 WFT3048 B Black 30 3 4 x 48 71074 WFT2640 N Nickel 26 3 4 x 40 71075 WFT2648 N Nickel 26 3 4 x 48 71078 WFT3040 N Nickel 30 3 4 x 40 71079 WFT2948 N Nickel 30 3 4 x 48 BLOWERS Cat No Model Description H7907 WSINS BLWR B SS Blower Insert Bl...

Page 25: ... 24 CAN 32 813mm Profondeur maximum de la tablette du manteau de cheminée 9 B Espaceentrel encastrableetlesmatériauxcombustibles du haut USA 18 CAN 26 660mm C Espace minimum entre l encastrable et le mur de côté combustible 18 450mm D Espace minimum entre l encastrable et les matériaux combustibles du côté 15 381mm E Minimumrequisdematérielnoncombustibleauplancher de chaque côté de l ouverture de ...

Page 26: ..._______________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________...

Page 27: ...binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry seasoned wood only c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from ...

Page 28: ...es 21 through 23 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The d...