       WARNING

The blower must be plugged directly into a properly 

grounded three-prong receptacle, 120 VAC, 60 Hz, single 

phase. Do not cut or remove the grounding prong from 

this plug.  Do not route power cord under or in front of 

appliance.

Installation must be in accordance with National Elec-

trical Code, ANSI/NFPA 70 - latest edition.  In Canada, 

the current CSA C22.1 Canadian Electrical Code - latest 

edition.

DANGER: Disconnect power before servicing blower.

BLOWER OPERATION

Figure 12 - Blower Wiring Schematic

Figure 11 - Blower Controls

Blower Operation

The blower can be operated manually or automatically (blower will 

turn on when the stove or insert is hot and turn off when the stove or 

insert is cool).  

The rocker switch on the control panel allows you to select between 

manual operation or automatic operation as follows (see Figure 10): 

MANUAL OPERATION:  Turn rocker switch to the manual position (up) 

and adjust rheostat knob to the desired speed. The blower will have to 

be manually turned “OFF” by rotating the rheostat knob counterclock-

wise until it clicks.

AUTO OPERATION: Turn rocker switch to the “AUTO” position and 

the rheostat to the ON position (rotate rheostat knob clockwise until it 

clicks). When the stove or insert warms up, the blower will automati-

cally turn on (adjust rheostat knob to the desired speed setting). When 

the stove or insert cools down, the blower will automatically turn off.

Rheostat Operation -  The highest blower speed is obtained by turning 

the rheostat knob clockwise until it clicks “ON”, then rotate towards 

“HIGH” to increase blower speed.  Rotate the knob clockwise for a 

lower speed.  To turn off, continue to rotate the knob counterclockwise 

until it clicks “OFF.”

Blower Speed Control 

Knob (rheostat)

Manual / Auto

Rocker Switch

Blower Operation Guidelines

While in auto operation mode, the blower will turn off and on based on 

the temperature of the appliance.  Auto operation ensures there is suffi-

cient heat build-up to warm the air being moved by the blower before the 

blower is turned on.  Likewise, when the appliance cools off, the blower 

is turned off to prevent circulating cool air. Depending on the size and 

intensity of the fire it may be necessary to adjust the blower speed ac-

cordingly to ensure uninterrupted blower operation. For example a small 

fire may require a slower blower speed to keep the heat output by the 

blower consistent.  If the blower is operated in manual mode, it may be 

necessary to adjust the blower speed as the fire begins to burn down and 

the appliance is no longer hot enough to effectively heat the air moved 

by the blower.  If the air coming from the blower feels cool, one should 

either decrease the blower speed or stoke the fire to build up more heat.

ROOM AIR

BLOWER

SPEED

CONTROL/OFF

TWO POSITION SWITCH

MANUAL/TEMPERATURE

AUTO-RESET TEMPERATURE

SWITCH N/O

POWER CORD

RED

RED

RED

YLW

BLK

WHT

GRN

NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE

N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN

         = FEMALE DISCONNECT
         = MALE DISCONNECT
         = STUD CONNECTION

ROOM AIR

BLOWER

SPEED

CONTROL/OFF

TWO POSITION SWITCH

MANUAL/TEMPERATURE

AUTO-RESET TEMPERATURE

SWITCH N/O

POWER CORD

RED

RED

RED

YLW

BLK

WHT

GRN

NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE

N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN

         = FEMALE DISCONNECT
         = MALE DISCONNECT
         = STUD CONNECTION

ROOM AIR

BLOWER

SPEED

CONTROL/OFF

TWO POSITION SWITCH

MANUAL/TEMPERATURE

AUTO-RESET TEMPERATURE

SWITCH N/O

POWER CORD

RED

RED

RED

YLW

BLK

WHT

GRN

NOTE: SWITCH CONDITIONS
GIVEN AT ROOM TEMPERATURE

N/C = NORMALLY CLOSED
N/O = NORMALLY OPEN

         = FEMALE DISCONNECT
         = MALE DISCONNECT
         = STUD CONNECTION

Summary of Contents for IronStrike Performer C210AGL

Page 1: ...uméro de la pièce 900980 01 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before installing and using your wood fireplace insert Failure to follow these instructions could result in property damage bodily injuryorevendeath Contactyourlocalbuildingorfireofficials to obtain a permit...

Page 2: ...ts 10 Installation Procedures Masonry Chimney 10 Positive Flue Connection 11 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fireplace Pre Installation Preparation 11 Insert Pre Installation Preparation 11 Chimney Liner Installation 13 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instruc...

Page 3: ... by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswithahotfire Iflargeaccumulations are occurring review your burning procedures 14 If a creosote fire should develop the fire department should be called immediately and then attempts should be made to control the fire until assistance arrives If a runaway fire should develop causing over heating of the insert the door a...

Page 4: ...ert is dependent upon a properly functioning chimney for optimum performance It is a high efficiency appliance that losesmuchlessheatupthechimneythanolderappliancesandfireplaces For this reason it is important to match the fireplace insert to the chimney The chimney has two functions 1 It draws combustion air into the appliance without air no fuel will burn and 2 It exhausts combustion by products...

Page 5: ...diately Other waste shall not be placedinthiscontainer Theclosedcontainerofashesshouldbeplacedon a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all the cinders have thoroughly cooled Ashes can ignite up to 72 h...

Page 6: ...MES RED REDUCE THE AMOUNT OF AIR ENTERING THE STOVE OR INSERT IMMEDIATELY BURN IN PERIOD PAINT CURING Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page 20 for a list of prohibited fuels Failure to burn proper fuels only will void the certification and the warranty of the appliance Dry seasoned wood is that which has been cut split and allowed to dry under a covered area where air is...

Page 7: ...install the two remaining boards where you originally installed the first two boards on each side of the baffle support and pushed against the rear of the unit The stainless steel support hanger should be centered left to right between the sets of baffle boards and placed as shown in Figure 4 3 Also included with the unit are two 15 x 10 x 1 thick baffle blan kets Install each blanket above the ba...

Page 8: ...the door opening of the unit Canada 18 450 mm minimum hearth extension on all stoves and inserts as measured from the door opening of the unit Minimum distance of floor protection to the side 8 200 mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada 2 J Maximum lintel depth without flue offset or smoke deflector NOTES Facing material that pr...

Page 9: ... asterisk indicates it is a value taken from Tables 2 and 3 FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate material kM x thickness alternate k value per inch of listed material TM of listed material kL material TL TM inches kM x TL 84 TM inches 35 x 375 84 156 inches 417 x 375 Answer Theminimumrequiredthick...

Page 10: ...er of the fireplace opening and push it back until the surround brackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug against thefireplaceface Thenwiththelocationselectedremovethesurround panels and level the fireplace insert with the leveling bolts using a 3 4 19 mm socket extensions to reach the bolt head and a ratchet 8 G...

Page 11: ...approved methods of achieving a positive flue connection See Figure 9 A qualified installer should evaluate the existing fireplace to determine the best method for achieving a positive flue connection between the vent pipe or liner and the existing fireplace chimney The most common method for achieving a positive flue connection in masonry fireplaces is to secure a seal off plate i e 22 gage sheet...

Page 12: ...Y BUILT ZERO CLEARANCE FIREPLACES FIREPLACE PRE INSTALLATION PREPARATION NOTE IHP RECOMMENDS PROFESSIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER SEE YOUR DEALER FOR RECOMMENDATIONS IMPROPER INSTALLATION OR MIS USE WILL VOID YOUR WARRANTY AND CREATE A SERIOUS SAFETY HAZARD Remove any doors or screen materials from the fireplace opening Re move the damper mechanism completely Also remove gr...

Page 13: ...t Part H5296 is available to fill the space between the insert and the hearth protection Install the brick and baffle as per Page 7 CHIMNEY LINER INSTALLATION INSTALLING THE INSERT POST INSTALLATION CHECKS Remove the existing chimney cap and install a stainless steel liner into the chimney if a special section has been used or drilled to attach to the insert it must be the bottom piece The next pi...

Page 14: ...hermometer can be a helpful tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor the temperature every 15 minutes or so until you become more familiar with your appliance Close the damper all the way down if you begin to reach 600 degrees as this is a si...

Page 15: ...o turn off continue to rotate the knob counterclockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch Blower Operation Guidelines While in auto operation mode the blower will turn off and on based on the temperature of the appliance Auto operation ensures there is suffi cient heat build up to warm the air being moved by the blower before the blower is turned on L...

Page 16: ...s locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few minutes to ignite the wood All IHP stoves and inserts are EPA tested for emissions at low burn with the air control completely closed Whether or not you should burn Your appliance with the air control...

Page 17: ...s are included with the graphite CAUTION Cleaning Glass Ensure appliance is cold prior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasivecleaners Donotcleanwithanymaterials which may scratch or otherwise damage the glass Scratches on the glass can develop into cracks or break Inspect the glass regularly If you detect a crack extinguish the fire and ...

Page 18: ...protective gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinstall Faceplate and Screws Reinstall faceplate onto door back and while holding the door assembly together flip the assembly back onto it s face Carefully reinstall the screws Be very careful not to ove...

Page 19: ...lass above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the baffle boards 2 Check the chimney for blockage due to creosote see Creosote section on Page 5 3 Check draft See POOR DRAFT section above WOOD BURNS 1 The draft control must be closed further TOO FAS...

Page 20: ...r requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Some people are more affected by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influen...

Page 21: ...Switch Bracket w hardware 18 H8082 Replacement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Switch Brushed Gold H8078 UHPII Blower Cage Snap Switch Brushed Nickel 29 H8064 Snap Switch w Gasket and Hardware 32 H8066 Control Switch Manual Off Automatic C210GL INSERT PARTS 33 71...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 33 34 36 36 45 46 47 37 37 35 40 44 40 38 38 38 41 38 38 38 41 38 38 42 38 38 38 38 42 38 38 39 39 43 39 39 REPLACEMENT PARTS MODEL C210TGL AND C210AGL ...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 REPLACEMENT PARTS MODEL C210TGL AND C210AGL Door Parts Blower Parts ...

Page 24: ...4 SURROUND TRIM THESE ARE NOT REQUIRED BUT AN OPTION 71021 WFT2640 B Black 26 3 4 x 40 71022 WFT2648 B Black 26 3 4 x 48 71025 WFT3040 B Black 30 3 4 x 40 71026 WFT3048 B Black 30 3 4 x 48 71074 WFT2640 N Nickel 26 3 4 x 40 71075 WFT2648 N Nickel 26 3 4 x 48 71078 WFT3040 N Nickel 30 3 4 x 40 71079 WFT2948 N Nickel 30 3 4 x 48 BLOWERS Cat No Model Description H7907 WSINS BLWR B SS Blower Insert Bl...

Page 25: ... 24 CAN 32 813mm Profondeur maximum de la tablette du manteau de cheminée 9 B Espaceentrel encastrableetlesmatériauxcombustibles du haut USA 18 CAN 26 660mm C Espace minimum entre l encastrable et le mur de côté combustible 18 450mm D Espace minimum entre l encastrable et les matériaux combustibles du côté 15 381mm E Minimumrequisdematérielnoncombustibleauplancher de chaque côté de l ouverture de ...

Page 26: ..._______________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________...

Page 27: ...binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry seasoned wood only c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from ...

Page 28: ...es 21 through 23 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The d...

Reviews: