NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

(A) Clearance from Insert top to Mantel = USA-24”, CAN-32" 

(813mm). Maximum mantel depth = 9"

(B) Clearance from insert  top to combustible = USA -18” 

CAN-26" (660mm)

(C) Minimum clearance to combustible sidewall = 18” (450mm)

(D) Minimum clearance to combustible side trim = 15” (381mm)

(E)  Minimum  distance  of  floor  protection  to  the  side  =  8” 

(200mm). This is measured from the sides of the door opening 

in the USA and from the sides of the insert in Canada.

(F) Minimum distance from front of insert to combustible 

 = 18” (450mm)

The hearth and/or floor protection must be a thermally rated non-combustible hearth/floor protector 

meeting or exceeding a thermal rating of k=.84 or equivalent with a listed thickness of 3/8" (9.5mm) 

minimum in USA (3/4" - 19mm minimum in Canada).  Install only in a masonry fireplace, built to UBC 

Chapter 37 or approved factory-built fireplace (USA only - see owner’s manual).  Do not remove 

brick or mortar from masonry fireplace to accommodate insert.  Use flue outlet with or without a 

direct connector.  Approved with minimum 6” (152mm) diameter stainless steel listed reline system.  

Remove and clean behind unit frequently, as creosote build up may occur rapidly.  See owner’s 

manual for reductions on mantel, trim and floor protection.

* Reduced clearances may be available for A, B, C, and D dimensions by using optional mantel and/or 

side shields.  Consult with your Innovative Hearth Products dealer for the dimensions of the shields.

** Hearth extension reductions: 2" (51mm) reduction for 2" (51mm) raised hearth.  16" (406mm) minimum 

hearth extension on all inserts as measured from the door opening of the unit.

"PREVENT HOUSE FIRES"

Install and use only in accordance with manu-

facturer's  installation  instructions  and  your 

local building codes. Do not connect this unit 

to a chimney flue serving another appliance.
Optional  Blower,  Part  No.s:  H7907  (black), 

H7909 (nickel), H7910 (brushed nickel)

Blower Electrical Rating: 120V, 60 Hz, 1 Amp

Do not route power cord under or in front of 

appliance.

Minimum Clearance to Combustible Materials - Inches (millimeters)

Serial No.

Numéro de série

Model / Modèle:  Performer™ C210TGL
 

Performer C210AGL

Tested to/Testé selon: UL 1482, ULC S628

Report No./Numéro de Rapport: 14-185

C210GL-

HOT  WHILE  IN  OPERATION.  DO  NOT 

TOUCH,  KEEP  CHILDREN,  CLOTHING 

AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. 

SEE  NAME-PLATE AND  INSTRUCTIONS.  DO  NOT  OVERFIRE 

-  IF  HEATER  OR  CHIMNEY  CONNECTOR  GLOWS,  YOU ARE 

OVERFIRING.  INSPECT AND CLEAN CHIMNEY FREQUENTLY - 

UNDER CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP 

MAY OCCUR RAPIDLY. DO NOT USE GRATE OR ELEVATE FIRE - BUILD WOOD FIRE 

DIRECTLY ON HEARTH. FEED DOOR MUST BE CLOSED DURING FIRING EXCEPT 

WHEN ADDING FUEL. KEEP ASH DOOR CLOSED TO AVOID EXCESS HEAT. DANGER: 

RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.  FOR 

USE WITH SOLID WOOD FUEL ONLY.

CAUTION:

Manufactured By / Fabriqué Par:

INNOVATIVE HEARTH PRODUCTS

1502 14th St NW

Auburn, WA 98001  USA

CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA

COMMUNIQUEZ AVEC LES AUTORITÉS LOCALES EN BÂTIMENT OU LE SERVICE DE PRÉVENTION DES INCENDIES POUR CONNAÎTRE LES NORMES D'INSTALLATION ET D'INSPECTION DE VOTRE RÉGION

Listed Factory-built or Masonry Fireplace Accessory/Insert / Poêle encastrable certifié pour installation dans un foyer de maçonnerie ou préfabriqué

"PREVENTION DES INCENDIES''

Installer et utiliser l'appareil en conformité avec 

les directives d'installation du fabricant et des 

autorités locales en bâtiment ou le service de 

prévention  des  incendies.  Ne  pas  brancher 

cette unité à un conduit de fumée raccordé à 

un autre appareil.
Type de combustible:  Bois seulement

Dégagements Minimums Aux Matériaux Combustibles - En Pouces (millimètres)

(A) Espace entre l'encastrable et le manteau de cheminée 

= USA-24”, CAN-32" (813mm). Profondeur maximum de la 

tablette du manteau de cheminée 9"

(B) Espace entre l'encastrable et les matériaux combustibles 

du haut = USA -18” CAN-26" (660mm)

(C) Espace minimum entre l'encastrable et le mur de côté 

combustible = 18” (450mm)

(D) Espace minimum entre l'encastrable et les matériaux 

combustibles du côté = 15” (381mm)

(E) Minimum requis de matériel non combustible au plancher, 

de chaque côté de l'ouverture de l'appareil = 8” (200mm)

(F) Minimum requis de matériel non combustible à l'avant 

de l'appareil = 18” (450mm)

Le panneau protecteur de plancher doit être un matériel non combustible, dont l'épaisseur minimale 

est de 3/4” - 19mm (3/8" - 9.5mm USA) et dont le facteur k est de 0.84 ou l'équivalent.  Installer seule-

ment dans un foyer de maçonnerie construit selon UBC Chapitre 37 ou dans un foyer approuvé 

par le fabricant (référez-vous au manuel).  Ne pas enlever de ciment ou de briques pour installer 

l'encastrable.  L'installation de la cheminée peut s'effectuer avec ou sans connecteur à la sortie de 

l'appareil.  Approuvé pour raccordement avec un conduit de tubage certifié en acier inoxydable de 

6” (152mm) de diamètre.  Tirer l'appareil et nettoyer l'arrière fréquemment car le créosote peut s'y 

accumuler rapidement.

*Les dégagements minimums peuvent être réduits pour A, B, C, D en utilisant un manteau option-

nel et / ou des protecteurs latéraux.  Contacter votre détaillant Innovative Hearth Products pour la 

dimension des protecteurs requise.

**Réduction du recouvrement de plancher : 2'' (51mm) de moins si  l'encastrable est élevé de 2'' 

(51mm).  Respecter 16'' (406mm) de recouvrement de plancher minimum à l'avant de  l'encastrable.

ATTENTION:

L'APPAREIL EST CHAUD LORS DE 

L’OPÉRATION. NE PAS Y TOUCHER. RISQUE DE BRÛLURES 

CUTANÉES. TENIR LES ENFANTS, LES MATÉRIAUX COMBUS-

TIBLES,  LES  VÊTEMENTS  ET  LES  MEUBLES  ELOIGNÉS  DE 

L’APPAREIL. VOIR LA PLAQUE SIGNALÉTIQUE ET LES DIREC-

TIVES.  NE PAS SURCHAUFFER L'APPAREIL. SI L’APPAREIL OU 

LE TUYAU DE CHEMINÉE ROUGIT, VOUS SURCHAUFFEZ. INSPECTER ET NETTOYER 

LA CHEMINÉE ET LE TUYAU CONNECTEUR FRÉQUEMMENT. SOUS CERTAINES 

CONDITIONS,  IL  SE  PEUT  QUE  LE  CRÉOSOTE  S’ACCUMULE  RAPIDEMENT.  NE 

SURÉLEVER PAS LE FEU À L'AIDE D'UN CHENET. DÉPOSER LES BÛCHES DE BOIS 

DIRECTEMENT SUR L’ÂTRE.  LA PORTE DOIT ÊTRE FERMÉE PENDANT L’USAGE 

SAUF POUR ALIMENTER LE FEU.  GARDER LA PORTE ''BY-PASS'' (CENDRES) FERMÉE 

POUR ÉVITER DE SURCHAUFFER. DANGER: RISQUES DE DÉCHARGE ÉLECTRIQUE. 

DÉCONNECTER LE FIL ÉLECTRIQUE DE LA PRISE DE CONTACT AVANT LE SERVICE. 

NE PAS FAIRE PASSER LE FIL ÉLECTRIQUE SOUS OU EN AVANT DE L’APPAREIL. 

POUR USAGE AVEC LE BOIS SEULEMENT.

NE PAS ENLEVER OU RECOUVRIR CETTE ÉTIQUETTE          Fabriqué aux  U.S.A.

Ventilateur Optionnel, No. De Pièces: H7907 (noir), 

H7909 (plaqué nickel), H7910 (plaqué nickel, fini 

brossé)

Spécification Électrique Du Ventilateur: 120V, 

60 Hz, 1 Amp

Trans Flow, QLN 652424-3045L
Ne pas faire passer le fil électrique sous ou en 

avant de l'appareil

Date of Manufacture /  Date De Fabrication

   2019   2020    2021   JAN.   FEB.   MAR.   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

   

 

 

JANV  FEVR  MARS  AVR  MAI  JUIN  JUIL  AOÛT  SEPT   OCT   NOV   DEC

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2020 cordwood standard.

Part No./ No. pièce  #900980-03  Rev. 0, 08/2019 

     DO NOT REMOVE THIS LABEL  

Made in  U.S.A.

C

US

This wood heater needs periodic inspection and repair for proper operation.

 

Consult the owner's 

manual for further information. It is against federal regulations to operate this wood heater in a 

manner inconsistent with the operating instructions in the owner's manual.

Certification test emission value 1.55 grams/hr per 2020 cordwood standard

Cet appareil de chauffage au bois doit être inspecté et entretenu périodiquement pour fonctionner 

correctement. Voir le manuel du propriétaire pour plus d'information. L'utilisation de cet appareil de 

chauffage au bois de manière incompatible avec les instructions du manuel du propriétaire constitue 

une infraction aux régulations fédérales.

Valeur d'émission du test d'homologation 1,55 g/h selon la norme 2020

SAFETY / LISTING LABEL - MODELS C210TGL AND C210AGL

Summary of Contents for IronStrike Performer C210AGL

Page 1: ...uméro de la pièce 900980 01 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before installing and using your wood fireplace insert Failure to follow these instructions could result in property damage bodily injuryorevendeath Contactyourlocalbuildingorfireofficials to obtain a permit...

Page 2: ...ts 10 Installation Procedures Masonry Chimney 10 Positive Flue Connection 11 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fireplace Pre Installation Preparation 11 Insert Pre Installation Preparation 11 Chimney Liner Installation 13 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instruc...

Page 3: ... by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswithahotfire Iflargeaccumulations are occurring review your burning procedures 14 If a creosote fire should develop the fire department should be called immediately and then attempts should be made to control the fire until assistance arrives If a runaway fire should develop causing over heating of the insert the door a...

Page 4: ...ert is dependent upon a properly functioning chimney for optimum performance It is a high efficiency appliance that losesmuchlessheatupthechimneythanolderappliancesandfireplaces For this reason it is important to match the fireplace insert to the chimney The chimney has two functions 1 It draws combustion air into the appliance without air no fuel will burn and 2 It exhausts combustion by products...

Page 5: ...diately Other waste shall not be placedinthiscontainer Theclosedcontainerofashesshouldbeplacedon a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all the cinders have thoroughly cooled Ashes can ignite up to 72 h...

Page 6: ...MES RED REDUCE THE AMOUNT OF AIR ENTERING THE STOVE OR INSERT IMMEDIATELY BURN IN PERIOD PAINT CURING Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page 20 for a list of prohibited fuels Failure to burn proper fuels only will void the certification and the warranty of the appliance Dry seasoned wood is that which has been cut split and allowed to dry under a covered area where air is...

Page 7: ...install the two remaining boards where you originally installed the first two boards on each side of the baffle support and pushed against the rear of the unit The stainless steel support hanger should be centered left to right between the sets of baffle boards and placed as shown in Figure 4 3 Also included with the unit are two 15 x 10 x 1 thick baffle blan kets Install each blanket above the ba...

Page 8: ...the door opening of the unit Canada 18 450 mm minimum hearth extension on all stoves and inserts as measured from the door opening of the unit Minimum distance of floor protection to the side 8 200 mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada 2 J Maximum lintel depth without flue offset or smoke deflector NOTES Facing material that pr...

Page 9: ... asterisk indicates it is a value taken from Tables 2 and 3 FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate material kM x thickness alternate k value per inch of listed material TM of listed material kL material TL TM inches kM x TL 84 TM inches 35 x 375 84 156 inches 417 x 375 Answer Theminimumrequiredthick...

Page 10: ...er of the fireplace opening and push it back until the surround brackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug against thefireplaceface Thenwiththelocationselectedremovethesurround panels and level the fireplace insert with the leveling bolts using a 3 4 19 mm socket extensions to reach the bolt head and a ratchet 8 G...

Page 11: ...approved methods of achieving a positive flue connection See Figure 9 A qualified installer should evaluate the existing fireplace to determine the best method for achieving a positive flue connection between the vent pipe or liner and the existing fireplace chimney The most common method for achieving a positive flue connection in masonry fireplaces is to secure a seal off plate i e 22 gage sheet...

Page 12: ...Y BUILT ZERO CLEARANCE FIREPLACES FIREPLACE PRE INSTALLATION PREPARATION NOTE IHP RECOMMENDS PROFESSIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER SEE YOUR DEALER FOR RECOMMENDATIONS IMPROPER INSTALLATION OR MIS USE WILL VOID YOUR WARRANTY AND CREATE A SERIOUS SAFETY HAZARD Remove any doors or screen materials from the fireplace opening Re move the damper mechanism completely Also remove gr...

Page 13: ...t Part H5296 is available to fill the space between the insert and the hearth protection Install the brick and baffle as per Page 7 CHIMNEY LINER INSTALLATION INSTALLING THE INSERT POST INSTALLATION CHECKS Remove the existing chimney cap and install a stainless steel liner into the chimney if a special section has been used or drilled to attach to the insert it must be the bottom piece The next pi...

Page 14: ...hermometer can be a helpful tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor the temperature every 15 minutes or so until you become more familiar with your appliance Close the damper all the way down if you begin to reach 600 degrees as this is a si...

Page 15: ...o turn off continue to rotate the knob counterclockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch Blower Operation Guidelines While in auto operation mode the blower will turn off and on based on the temperature of the appliance Auto operation ensures there is suffi cient heat build up to warm the air being moved by the blower before the blower is turned on L...

Page 16: ...s locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few minutes to ignite the wood All IHP stoves and inserts are EPA tested for emissions at low burn with the air control completely closed Whether or not you should burn Your appliance with the air control...

Page 17: ...s are included with the graphite CAUTION Cleaning Glass Ensure appliance is cold prior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasivecleaners Donotcleanwithanymaterials which may scratch or otherwise damage the glass Scratches on the glass can develop into cracks or break Inspect the glass regularly If you detect a crack extinguish the fire and ...

Page 18: ...protective gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinstall Faceplate and Screws Reinstall faceplate onto door back and while holding the door assembly together flip the assembly back onto it s face Carefully reinstall the screws Be very careful not to ove...

Page 19: ...lass above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the baffle boards 2 Check the chimney for blockage due to creosote see Creosote section on Page 5 3 Check draft See POOR DRAFT section above WOOD BURNS 1 The draft control must be closed further TOO FAS...

Page 20: ...r requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Some people are more affected by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influen...

Page 21: ...Switch Bracket w hardware 18 H8082 Replacement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Switch Brushed Gold H8078 UHPII Blower Cage Snap Switch Brushed Nickel 29 H8064 Snap Switch w Gasket and Hardware 32 H8066 Control Switch Manual Off Automatic C210GL INSERT PARTS 33 71...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 33 34 36 36 45 46 47 37 37 35 40 44 40 38 38 38 41 38 38 38 41 38 38 42 38 38 38 38 42 38 38 39 39 43 39 39 REPLACEMENT PARTS MODEL C210TGL AND C210AGL ...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 REPLACEMENT PARTS MODEL C210TGL AND C210AGL Door Parts Blower Parts ...

Page 24: ...4 SURROUND TRIM THESE ARE NOT REQUIRED BUT AN OPTION 71021 WFT2640 B Black 26 3 4 x 40 71022 WFT2648 B Black 26 3 4 x 48 71025 WFT3040 B Black 30 3 4 x 40 71026 WFT3048 B Black 30 3 4 x 48 71074 WFT2640 N Nickel 26 3 4 x 40 71075 WFT2648 N Nickel 26 3 4 x 48 71078 WFT3040 N Nickel 30 3 4 x 40 71079 WFT2948 N Nickel 30 3 4 x 48 BLOWERS Cat No Model Description H7907 WSINS BLWR B SS Blower Insert Bl...

Page 25: ... 24 CAN 32 813mm Profondeur maximum de la tablette du manteau de cheminée 9 B Espaceentrel encastrableetlesmatériauxcombustibles du haut USA 18 CAN 26 660mm C Espace minimum entre l encastrable et le mur de côté combustible 18 450mm D Espace minimum entre l encastrable et les matériaux combustibles du côté 15 381mm E Minimumrequisdematérielnoncombustibleauplancher de chaque côté de l ouverture de ...

Page 26: ..._______________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________...

Page 27: ...binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry seasoned wood only c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from ...

Page 28: ...es 21 through 23 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The d...

Reviews: