Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your IronStrike

®

 Brand Wood Burning Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime 

Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 

Limited Lifetime Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If 

repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will 

also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS 

AND LIMITATIONS to this Limited Lifetime Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded from 

this Limited Lifetime Warranty. The following do not carry a Limited Lifetime Warranty but are warranted as follows:

Cast Iron Heat Exchanger – Replacement for five years from the date of installation

Cast iron parts – Replacement for one year from the date of installation

Catalyst – Carries a separate warranty. Refer to the warranty certificate provided for that part

Electrical components – Repair or replacement for one year from date of installation

Gaskets – Replacement for one year from the date of installation.

Gold & nickel plating – Replacement for two years from date of installation. Excludes tarnishing

Refractory & screens – Replacement for two years from date of installation. Excludes hairline cracks

Removable air tubes – Repair or replacement for seven years from date of installation. IHP prevailing labor rates for years one through five.

Labor coverage – Prevailing IHP labor rates apply for the warranty period of the component, unless otherwise noted

Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation 

Manual provided with the product. Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwood, coal or plywood and wood products 

using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly; IHP stoves, inserts and high efficiency EPA 

fireplaces are approved for burning dry seasoned wood only.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions 

provided with the Product; (d) damages, repairs or  inefficiency resulting from faulty installation or application of the Product.
Coverage of this Limited Lifetime Warranty is conditional upon the appliance being operated without the use of grates, irons or any other method to elevate the fire.
IHP is not responsible for inadequate system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions which 

may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by inadequate 

chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions. Certain IHP Products are listed for use with Security 

Chimneys International, Ltd. chimney systems only. Use of chimney components other than that specified in the Product manual will void the Product warranty.
This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due 

to any malfunction or defect in equipment are not covered by this Limited Lifetime Warranty. All replacement or repair components will be shipped F.O.B. from the nearest 

stocking IHP factory.
LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited 

Lifetime Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a contrac-

tor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ 

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.IRONSTRIKE.US.COM.

Summary of Contents for IronStrike Performer C210AGL

Page 1: ...uméro de la pièce 900980 01 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before installing and using your wood fireplace insert Failure to follow these instructions could result in property damage bodily injuryorevendeath Contactyourlocalbuildingorfireofficials to obtain a permit...

Page 2: ...ts 10 Installation Procedures Masonry Chimney 10 Positive Flue Connection 11 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fireplace Pre Installation Preparation 11 Insert Pre Installation Preparation 11 Chimney Liner Installation 13 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instruc...

Page 3: ... by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswithahotfire Iflargeaccumulations are occurring review your burning procedures 14 If a creosote fire should develop the fire department should be called immediately and then attempts should be made to control the fire until assistance arrives If a runaway fire should develop causing over heating of the insert the door a...

Page 4: ...ert is dependent upon a properly functioning chimney for optimum performance It is a high efficiency appliance that losesmuchlessheatupthechimneythanolderappliancesandfireplaces For this reason it is important to match the fireplace insert to the chimney The chimney has two functions 1 It draws combustion air into the appliance without air no fuel will burn and 2 It exhausts combustion by products...

Page 5: ...diately Other waste shall not be placedinthiscontainer Theclosedcontainerofashesshouldbeplacedon a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all the cinders have thoroughly cooled Ashes can ignite up to 72 h...

Page 6: ...MES RED REDUCE THE AMOUNT OF AIR ENTERING THE STOVE OR INSERT IMMEDIATELY BURN IN PERIOD PAINT CURING Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page 20 for a list of prohibited fuels Failure to burn proper fuels only will void the certification and the warranty of the appliance Dry seasoned wood is that which has been cut split and allowed to dry under a covered area where air is...

Page 7: ...install the two remaining boards where you originally installed the first two boards on each side of the baffle support and pushed against the rear of the unit The stainless steel support hanger should be centered left to right between the sets of baffle boards and placed as shown in Figure 4 3 Also included with the unit are two 15 x 10 x 1 thick baffle blan kets Install each blanket above the ba...

Page 8: ...the door opening of the unit Canada 18 450 mm minimum hearth extension on all stoves and inserts as measured from the door opening of the unit Minimum distance of floor protection to the side 8 200 mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada 2 J Maximum lintel depth without flue offset or smoke deflector NOTES Facing material that pr...

Page 9: ... asterisk indicates it is a value taken from Tables 2 and 3 FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate material kM x thickness alternate k value per inch of listed material TM of listed material kL material TL TM inches kM x TL 84 TM inches 35 x 375 84 156 inches 417 x 375 Answer Theminimumrequiredthick...

Page 10: ...er of the fireplace opening and push it back until the surround brackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug against thefireplaceface Thenwiththelocationselectedremovethesurround panels and level the fireplace insert with the leveling bolts using a 3 4 19 mm socket extensions to reach the bolt head and a ratchet 8 G...

Page 11: ...approved methods of achieving a positive flue connection See Figure 9 A qualified installer should evaluate the existing fireplace to determine the best method for achieving a positive flue connection between the vent pipe or liner and the existing fireplace chimney The most common method for achieving a positive flue connection in masonry fireplaces is to secure a seal off plate i e 22 gage sheet...

Page 12: ...Y BUILT ZERO CLEARANCE FIREPLACES FIREPLACE PRE INSTALLATION PREPARATION NOTE IHP RECOMMENDS PROFESSIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER SEE YOUR DEALER FOR RECOMMENDATIONS IMPROPER INSTALLATION OR MIS USE WILL VOID YOUR WARRANTY AND CREATE A SERIOUS SAFETY HAZARD Remove any doors or screen materials from the fireplace opening Re move the damper mechanism completely Also remove gr...

Page 13: ...t Part H5296 is available to fill the space between the insert and the hearth protection Install the brick and baffle as per Page 7 CHIMNEY LINER INSTALLATION INSTALLING THE INSERT POST INSTALLATION CHECKS Remove the existing chimney cap and install a stainless steel liner into the chimney if a special section has been used or drilled to attach to the insert it must be the bottom piece The next pi...

Page 14: ...hermometer can be a helpful tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top of the appliance Monitor the temperature every 15 minutes or so until you become more familiar with your appliance Close the damper all the way down if you begin to reach 600 degrees as this is a si...

Page 15: ...o turn off continue to rotate the knob counterclockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch Blower Operation Guidelines While in auto operation mode the blower will turn off and on based on the temperature of the appliance Auto operation ensures there is suffi cient heat build up to warm the air being moved by the blower before the blower is turned on L...

Page 16: ...s locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few minutes to ignite the wood All IHP stoves and inserts are EPA tested for emissions at low burn with the air control completely closed Whether or not you should burn Your appliance with the air control...

Page 17: ...s are included with the graphite CAUTION Cleaning Glass Ensure appliance is cold prior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasivecleaners Donotcleanwithanymaterials which may scratch or otherwise damage the glass Scratches on the glass can develop into cracks or break Inspect the glass regularly If you detect a crack extinguish the fire and ...

Page 18: ...protective gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinstall Faceplate and Screws Reinstall faceplate onto door back and while holding the door assembly together flip the assembly back onto it s face Carefully reinstall the screws Be very careful not to ove...

Page 19: ...lass above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the baffle boards 2 Check the chimney for blockage due to creosote see Creosote section on Page 5 3 Check draft See POOR DRAFT section above WOOD BURNS 1 The draft control must be closed further TOO FAS...

Page 20: ...r requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Some people are more affected by carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influen...

Page 21: ...Switch Bracket w hardware 18 H8082 Replacement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Switch Brushed Gold H8078 UHPII Blower Cage Snap Switch Brushed Nickel 29 H8064 Snap Switch w Gasket and Hardware 32 H8066 Control Switch Manual Off Automatic C210GL INSERT PARTS 33 71...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 33 34 36 36 45 46 47 37 37 35 40 44 40 38 38 38 41 38 38 38 41 38 38 42 38 38 38 38 42 38 38 39 39 43 39 39 REPLACEMENT PARTS MODEL C210TGL AND C210AGL ...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 REPLACEMENT PARTS MODEL C210TGL AND C210AGL Door Parts Blower Parts ...

Page 24: ...4 SURROUND TRIM THESE ARE NOT REQUIRED BUT AN OPTION 71021 WFT2640 B Black 26 3 4 x 40 71022 WFT2648 B Black 26 3 4 x 48 71025 WFT3040 B Black 30 3 4 x 40 71026 WFT3048 B Black 30 3 4 x 48 71074 WFT2640 N Nickel 26 3 4 x 40 71075 WFT2648 N Nickel 26 3 4 x 48 71078 WFT3040 N Nickel 30 3 4 x 40 71079 WFT2948 N Nickel 30 3 4 x 48 BLOWERS Cat No Model Description H7907 WSINS BLWR B SS Blower Insert Bl...

Page 25: ... 24 CAN 32 813mm Profondeur maximum de la tablette du manteau de cheminée 9 B Espaceentrel encastrableetlesmatériauxcombustibles du haut USA 18 CAN 26 660mm C Espace minimum entre l encastrable et le mur de côté combustible 18 450mm D Espace minimum entre l encastrable et les matériaux combustibles du côté 15 381mm E Minimumrequisdematérielnoncombustibleauplancher de chaque côté de l ouverture de ...

Page 26: ..._______________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________...

Page 27: ...binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry seasoned wood only c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d damages repairs or inefficiency resulting from ...

Page 28: ...es 21 through 23 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The Serial Number of the appliance 3 The part number 4 The d...

Reviews: