SuperiorFireplaces.us.com
126631-01_H
5
FIREPLACE INSTALLATION
SELECTING LOCATION
To determine safest and most efficient location for fireplace, you
must take into consideration the following guidelines:
1. Location must allow for proper clearances (see Figures 1 and 2).
2. Consider a location where fireplace will not be affected by drafts,
air conditioning ducts, windows or doors.
3. A location that avoids cutting of joists or roof rafters will make
installation easier.
4. An outside air kit is available with this fireplace (see Optional
Outside Air Kit on page 7).
MINIMUM CLEARANCE TO COMBUSTIBLES
Back and sides of fireplace 3/4" (19 mm) minimum*
Floor** 0" (0 mm) minimum
Perpendicular wall to opening 12" (305 mm) minimum
Top spacers 0" (0 mm) minimum
Mantel clearances see Mantels, page 6
Chimney outer pipe surface 1" (26 mm) minimum
* Not required at nailing flanges
** See step 2 of Framing
WARNING: DO NOT PACK REQUIRED AIR SPACES
WITH INSULATION OR OTHER MATERIALS.
Minimum/Maximum Chimney Height
Minimum height of chimney, measured from base of fireplace to
flue gas outlet of termination, is 14.5 feet for straight flue or a flue
with one elbow set. Maximum distance between elbows is 6 feet. For
systems with two elbow sets, minimum height is 22 feet. Maximum
height of any system is 50 feet. This measurement includes fireplace,
chimney sections and height of termination assembly at level of flue
gas outlet (see Figure 20, page 12).
FRAMING
1. Frame opening for fireplace using dimensions shown in Figures
1 and 2.
2. If fireplace is to be installed directly on carpeting, tile or any
combustible material other than wood flooring, fireplace must
be installed upon a metal or wood panel extending full width and
depth of fireplace.
3. Set fireplace directly in front of this opening and slide unit back
until nailing flanges touch side framing.
4. Check level of fireplace and shim with sheet metal if necessary.
5. Before securing fireplace to prepared framing, ember protector
must be placed between hearth extension (not included) and
under bottom front edge of fireplace to protect against glowing
embers falling through. If fireplace is to be installed on a raised
platform, a Z-type ember protector (not included) must be fabri-
cated to fit your required platform height. Ember protector should
extend under fireplace a minimum of 1
1
/
2
". Ember protector
should be made of galvanized sheet metal (28 gauge minimum)
to prevent corrosion.
6. Using screws or nails, secure fireplace to framing through flanges
located on sides of fireplace.
37
5
/
8
"
(956 mm)
44
1
/
4
" (1124 mm)
22"
(559 mm)
Figure 1 - Framing Dimensions
22
1
/
2
"
(572 mm)
15
7
/
8
"
(404 mm)
Maintain
3
/
4
"
(19 mm) Clearance
at Sides and
Back of Fireplace
3
/
4
" (19 mm) Clearance Not
Reaquired at Nailing Flanges
52
1
/
2
"
(1334 mm)
72
7
/
8
"
(1851 mm)
Figure 2 - Corner Installation
HEARTH EXTENSION
A hearth extension projecting a minimum of 20" in front of and a
minimum of 12" beyond each side of fireplace opening is required
to protect combustible floor construction in front of fireplace. Fab-
ricate a hearth extension using a material which meets the following
specifications: a layer of noncombustible, inorganic material having
a thermal conductivity of k = .84 BTU IN/FT
2
HR °F (or less) at 1"
thick. For example, if material selected has a k factor of 0.25, such
as glass fiber, the following formula would apply:
0.25 x 1.0" = 0.30" thickness required
0.84
Thermal conductivity "k" of materials can be obtained from manu-
facturer or supplier of noncombustible material. If hearth extension
is to be covered, use noncombustible material such as tile, slate,
brick, concrete, metal, glass, marble, stone, etc. Provide a means to
prevent hearth extension from shifting and seal gap between fireplace
frame and hearth extension with a non-combustible material such
as sand-cement grout (see Figure 3, page 6).