background image

SAFETY / LISTING LABEL - WRT3920WS

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

31

Model / Modèle:  W

RT3920WS

CLEARANCES TO COMBUSTIBLES:

SIDE 

W

ALL (FROM DOOR EDGE)

 

24 in. (610 mm)

MANTEL (ABOVE FIREPLACE’S BASE)

 39 in. (990 mm)

BACK 

W

ALL (FROM S

PACERS)

 

0 in. 

 (0 mm)

ABOVE THE FIREPLACE (FROM 

      THE BASE OF THE FIREPLACE)

 

6 ft. 8 in. (2032 mm)

CHIMNEY 

2 in. 

 (51 mm)

DÉGAGEMENTS AUX COMBUSTIBLES:

MUR L

ATÉRAL (DE 

L’OUVE

RTURE DE LA PO

RTE)

 

24 po.

 (610 mm)

LINTEAU (AU-DESSUS DE LA BASE DU FOYER)

 

39 po.

 (990 mm)

MUR ARRIÈRE ET CÔTÉ DU FOYER (DES ES

PACEURS)

 0 po. 

 (0 mm)

AU-DESSUS DU FOYER (À 

PA

RTIR DE LA BASE 

      DU FOYER) 

6 pi. 8 po. (2032 mm)

CHEMINÉE 

2 po. 

 (51 mm)

Conforms to / Conforme au :  UL STD 127

Certified to / Certifié au :   ULC STD S610

LISTED 

FACTO

RY BUI

LT FIREPLACE

FOYER PRÉ

FABRIQUE HOMOLOGUÉ

Manufactured by / Fabriqué par: INNO

VA

TIVE HEA

RTH PRODUCTS

1502 14th St. NW

Auburn, 

W

A  98001 USA

P/N 900842-01, RE

V. 0, 02/2018

• 

USE WOOD FUEL ON

LY

• 

NON

 COMBUSTIBLE

 HEA

RTH

 EXTENSION

 MUST

 BE 

INS

TA

LL

ED

 AT

 FRO

NT

 O

F U

NI

T E

XT

END

ING

 18

 in.

 (45

mm

) A

FRO

NT

 AN

36

 in

. (

91

mm

) W

ID

MI

NIMUM.

• 

TH

IS

 F

IRE

PLAC

HAS

 NOT

 B

EE

N

 TE

ST

ED

 W

IT

UNVENTED

 GAS

 LOG

 SE

T.

 TO

 REDUCE

 RISK

 OF

 FIRE 

OR

 INJU

RY

 DO

 NOT

 INS

TALL

 AN

 UNVENTED

 GAS

 LOG 

SET INTO THE FIREPLACE.

• 

ELECTRICAL R

ATING:  120 

V, 60 Hz

• 

CHIMNEY

 TYPE:

 USE

 ON

LY

 WITH

 LISTED

 6

 in.

 DIAM

-

ETER

 CHIMNE

Y,

 CE

RTIFIED

 MODEL

 ASHT+,

 S-2100+, 

, , AC OR 7 in. ASH

T, HT6103.

• 

CAN

 BE

 CONNECTED

 TO

 A

 MASON

RY

 CHIMNEY

 AS 

DESCRIBED IN THE INS

TALL

ATION INSTRUCTIONS.

• 

COMPONENTS

 USED

 WITH

 THE

 FIREPLACE

 MUST

 BE 

LISTED.

  SEE

 LIST

 IN

 THE

 INS

TALL

ATION

 INSTRUC

-

TIONS.

• 

REPL

ACE

 G

LA

SS

 W

IT

CE

RAM

IC

 G

LASS

 5

 m

m

 T

HIC

K.

• 

FOR

 SAFE

 OPER

ATION

 INS

TALL

 IN

 ACCORDANCE 

WITH THE MANU

FACTURER’S INSTRUCTIONS.

• 

CAUTION:

 COMBUSTION

 AIR

 OPENING

 MUST

 NOT

 BE 

OBSTRUCTED.

• 

DO NOT OVERFIRE THE FIREPLACE.

• 

OPER

ATE

 THE

 FIREPLACE

 WITH

 DOOR

 FUL

LY

 OPEN 

OR FUL

LY CLOSED ON

LY

.

• 

DO

 NOT

 USE

 A

 FIREPLACE

 IN

SE

RT

 OR

 OTHER

 PRODUCT

NOT

 S

PE

CI

FIED

 FOR

 USE

 W

ITH 

THIS

 PRODUC

T

• 

POUR USAGE 

AVEC LE BOIS SEULEMENT

• 

UN

 T

ABLIER

 NON

 COMBUSTIBLE

 DOIT

 ÊTRE

 INS

TALLÉ

 À

 L’

AV

ANT 

DU

 FOYER

 . 

DIMENSION

 MINIMALE

 DE

 18

 po.

 (457

 mm)

 P

AR

 36 

po. (914 mm) DE LARGE.

• 

CE

 FOYER

 N’EST

 P

AS

 HOMOLOGUÉ

 POUR

 ÊTRE

 UTILISÉ

 A

VEC

 UN 

ENSEMBLE

 DE

 BÛCHES

 À

 GAZ

 SANS

 CONDUIT

 D’É

VACU

ATION. 

AFIN

 DE

 RÉDUIR

LES

 R

ISQ

U

ES

 D

’IN

CENDI

OU

 DE

 B

LE

S-

SURES,

 N’INS

TALLEZ

 P

AS

 DE

 BÛCHES

 À

 GAZ

 SANS

 CONDUIT 

D’É

VACU

ATION À 

L’INTÉRIEUR DE CE FOYER.

• 

ALIMEN

TA

TION ÉLECTRIQUE: 120

V, 60 Hz

• 

UTILISER

 SEULEMENT

 A

VEC

 UNE

 CHEMINÉE

 6

 po.

 (150

 mm)

 DE 

DIAMÈTRE,

 MODÈLE

 ASHT+,

 S2100+,

 ,

 

 OU

 AC 

HOMOLOGUÉE OU 7 po. (175mm) ASH

T, HT6103.

• 

PEUT

 ÊTRE

 RACCORDÉ

 SUR

 UNE

 CHEMINÉE

 DE

 MAÇONNERIE 

TEL QUE DÉCRIT DANS LE MANUEL D’INS

TALL

ATION.

• 

LE

CO

M

POS

ANT

ES

 U

TI

LI

SÉES

 A

VEC

 LE

 FO

YER

 DO

IV

ENT

 ÊTR

E H

O-

MOLOGUÉES.

 VOIR

 LA

 LISTE

 DANS

 LE

 MANUEL

 D’INS

TALL

ATION.

• 

REMPLACER

 LA

 VITRE

 A

VEC

 UN

 VERRE

 CÉRAMIQUE

 DE

 5mm 

D’É

PAISSEUR.

• 

POUR

 UNE

 UTILIS

ATION

 SÉCURI

TAIRE,

 INS

TALLER

 CONFORMÉ

-

MENT AUX DIRECTIVES DU 

FABRICAN

T.

• 

AT

TE

NT

IO

: N

E P

AS

 O

BST

RU

ER

 LES

 A

RR

IVÉ

ES

 D

’AI

CO

M

BU

RAN

T.

• 

NE 

PAS 

FAIRE SURCHAUFFER LE FOYER.

• 

LA

 PO

RTE

 DU

 FOYER

 DOIT

 DEMEURER

 TO

TALEMENT

 OUVE

RTE 

OU TO

TALEMENT FERMÉE LORSQUE LE FOYER FONCTIONNE.

• 

N

PAS

 U

TIL

IS

ER

 D

POÊLE

 E

NCA

ST

R

AB

LE

 O

U

 D

’A

UTRE

PRODUITS

 NON

 SPÉCIFIÉS

 COMME

 É

TANT

 UTILISABLES

 A

VEC 

CE PRODUI

T.

• 

CON

TACT

 YOUR

 LOCAL

 BUILDING

 OR

 FIRE

 OFFICIALS

 ABOUT

 RESTRICTIONS

 AND

 INS

TALL

ATION

 INSPECTIONS

 IN

 YOUR 

AREA.

• 

CON

TACTEZ LES RESPONSABLES DE VOTRE REGION A PROPOS DES RESTRICTIONS ET INSPECTIONS D’INS

TALL

ATION.

• 

SEE IHP INS

TALL

ATION AND OPER

ATING INSTRUCTIONS FOR THIS MODEL.

• 

INS

TALL AND USE ON

LY IN ACCORDANCE WITH THE MANU

FACTURER’S INSTRUCTIONS AND LOCAL BUILDING CODES.

• 

SPECIAL

 METHODS

 ARE

 REQUIRED

 WHEN

 P

ASSING

 THROUGH

 A

 W

ALL

 OR

 CEILING.

 SEE

 INSTRUCTIONS

 AND

 BUILDING 

CODES.

• 

PREVENT CREOSOTE FIRE: INSPECT CHIMNEY CONNECTOR AND CHIMNEY FLUE MONTH

LY AND CLEAN IF NECESSA

RY

• 

 DO NOT OVERFIRE. IF DOME OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING.

• 

KEEP FURNISHINGS AND OTHER COMBUSTIBLE M

ATERIALS A CONSIDERABLE DIS

TANCE 

AW

AY FROM APPLIANCE.

• 

MAINTENIR LES MEUBLES ET AUTRES OBJETS À UNE DIS

TANCE SÉCURI

TAIRE DU FOYER.

• 

THIS

 WOOD

 HE

ATER

 NEEDS

 PERIODIC

 INSPECTION

 AND

 RE

PAIR

 FOR

 PROPER

 OPER

ATION.

 CONSU

LT

 THE

 OWNER’S 

MANUAL

 FOR

 FU

RTHER

 INFORM

ATION.

 IT

 IS

 AGAINST

 FEDERAL

 REGUL

ATIONS

 TO

 OPER

ATE

 THIS

 WOOD

 HE

ATER

 IN

 A 

MANNER INCONSISTENT WITH THE OPER

ATING INSTRUCTIONS IN THE OWNER’S MANUAL.

• 

CET

 AP

PAREIL

 DE

 CHAUF

FAGE

 AU

 BOIS

 DOIT

 ÊTRE

 INSPECTE

 ET

 ENTRETENU

 PÉRIODIQUEMENT

 POUR

 FONCTIONNER 

CORRECTEMEN

T.

 VOIR

 LE

 MANUEL

 DU

 PROPRIÉ

TAIRE

 POUR

 PLUS

 D’INFORM

ATION.

 L’UTILIS

ATION

 DE

 CET

 AP

PAREIL

 DE 

CHAUF

FAGE

 AU

 BOIS

 DE

 MANIÈRE

 INCOM

PA

TIBLE

 A

VEC

 LES

 INSTRUCTIONS

 DU

 MANUEL

 DU

 PROPRIÉ

TAIRE

 CONSTITUE 

UNE INFRACTION AUX RÉGUL

ATIONS FÉDÉRALES.

DA

TE OF MFG. 

1     2     3     4     5     6     7     8     9    10    11    12

2018-19-20-21-22-23-24

INS

TALL WITH MINIMUM CLEARANCES TO 

W

ALL 

AS SHOWN IN INCHES.

SIDE

W

ALL - BACK

W

ALL

INS

TALL

ATION

0”

0”

FIREPLACE

FRONT

CORNER INS

TALL

ATION

0”

0”

FIREPLACE

FRONT

FLOOR PROTECTOR MINIMUM DIS

TANCE 

FROM OPENING IN INCHES

HEA

RTH EXTENSION M

ATERIAL :

-   

 3/8 “ THICKNESS NON COMBUSTIBLE 

M

ATERIAL

-   

 OR EQUI

VALENT

FIREPLACE

FRONT

18”

36”

U.S. ENVIRONMEN

TA

L PROTECTION

 AGENCY

Certified to comply with 2020 particulate emission standards 

using crib wood.

C

US

Report No. / Rapport nº

14-181

Serial No. Numéro de série

Certification test emission value 1.8 g/hr per 2020 standard Valeur d’émission du test d’homologation 1,8 g/h selon la norme 2020

Summary of Contents for Superior Fireplaces WRT3920WS

Page 1: ...andapprovalsofthissystem and could result in an unsafe and potentially dangerous installation IHP wood burning fireplaces are designed for use as a supplemental heater They are not intended for contin...

Page 2: ...intended for use with a gas log set Do not use a fireplace insert or any other product with this fireplace unless it is specified by IHP for use with this appliance Failure to follow these instructio...

Page 3: ...length to be blown in front ofanopenflamewhenthewindow is opened Keep any combustible furniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Never leav...

Page 4: ...sthecatalyticcombustor Openingthe CAT bypass damper control increases the draft allowing the unit to achieve proper operating temperatures during a cold start up It also provides more draft to prevent...

Page 5: ...For instance a long chimney will necessitate closing the damper more To obtain the proper combustion closethedampercompletely then open it about 1 4 to 1 2 6 4mm to 13mm Two medium size pieces of woo...

Page 6: ...kesabout15 30minuteswiththeCATbypass opened to reach proper light off temperatures for the catalytic combustor Step 5 Set the primary control to the desired burn level The fireplace will automatically...

Page 7: ...ed to less than 20 Wood properly seasoned is then capable of generating the heat the stove was designed to provide Greenwooddoesnotburneasily Attemptingto burn green wood often results in a lot of smo...

Page 8: ...sweep and put the combustor back in place CATALYTIC COMBUSTOR This fireplace is designed with a catalytic com bustor which will reduce pollution emissions and creosote build up while improving therma...

Page 9: ...better seal and then retightening Catalyst Bypass linkage replacement see Figure 9B Toolsrequired 2 9 16 wrenches 2square drive bit driver Withcatalystbypassinclosedposition remove 2 baffle boards fr...

Page 10: ...ombustorProblem Thermal Cracking ThiscombustordoesNOTexperiencethermalcracking Notap plicable Appliestohoneycombcombustorsonly CombustorProblem CombustorPeeling ThiscombustordoesNOTexperiencecombustor...

Page 11: ...the ashes are cold 24 to 48 hours after the fire is out Do not leave the ashes in the house as they give off carbon monoxide and other toxic gases WARNING DisposalofAshes Ashesshould be placed in a st...

Page 12: ...e Replacement Parts Page 28 DO NOT OPERATE THE UNIT WITH CRACKED OR BROKEN GLASS Glass Cleaning TheWRT3920WSfireplaceisdesignedtokeeptheglasscleanundernormal operating conditions If the WRT3920WS fire...

Page 13: ...replace is determined by considering the location of windows doors and the traffic flow in the room where the fireplace is located allowing space in front of the unit for the hearth exten sion and the...

Page 14: ...must cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with at least a 1 2 inch of non combustible material tile marble stone etc See Figure 15 CO...

Page 15: ...phs are not to scale consult installation instructions Product designs materials dimensions specifications colorsandpricesaresubjecttochangeordiscontinu ance without notice Allframingdimensionscalcula...

Page 16: ...Side Figure 17 Figure 18 Insulated Chase Construction 7 Ft Min Attic Radiation Shield Roof Support Storm Collar Flashing Drywall or Any Rigid Material 2 x 4 1 2 Plywood 6 8 Min Firestop Floor Ceiling...

Page 17: ...mbustible Facing Drywall 2 x 3 Min Rock Board or Other Spacer Figure 22 A wall on off switch must be installed to control theblower Anoptionalheatswitchandvariable speed control are available see Page...

Page 18: ...ust be non combustible below this area u NOTES Seal the top and both sides of the roof flashing with waterproof caulk ing The gap between the vent pipe and a vertical firestop shall be sealed with non...

Page 19: ...the base of the fireplace C The fresh air must come from outside the house The air intake must not draw air from the attic basement or garage D The air intake should be installed where it is not likel...

Page 20: ...2 feet 3 7 m In altitude add 18 450 mm to the chimney for every 2 000 feet 600 m above sea level 6 All chimney installations must include at least one support Re ducing the amount of chimney weight on...

Page 21: ...the joint between the roof and the flashing with roofing pitch see Figures 34 and 35 For sloping roofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to...

Page 22: ...b bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install...

Page 23: ...6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 2432 mm...

Page 24: ...Insulated Wall Angel Wall Radiation Shield Insulated Available from Security Chimneys Available from DuraVent Security Chimneys RSM and RSMI30 RSMI45 Canada Only DuraVent 6DTC WTI and 6DTC S30 6DTC S...

Page 25: ...AND MULTIPLE TERMINATIONS For the purpose of this manual a chimney chase is considered a part of the chimney system rather than part of a building The termination must be placed a minimum of 18 460 mm...

Page 26: ...rily install the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in...

Page 27: ...er EPA certification If installed this appliance no longer qualifies for EPA certification Check with local authorities having jurisdiction for requirements in your area Central Forced Air Kit Accesso...

Page 28: ...ription Part Cat No Andiron 2 pieces PR SR2875 Bottom refractory PR SR2825 Back refractory PR SR2826 Left side refractory PR SR2828 Right side refractory PR SR2827 Front refractory 2 pieces PR SR2829...

Page 29: ...nd PE Wall Band BM Supports Offset Support SO Roof Support ST Roof Brace BS2 Firestops Firestop 6BF Radiation Shield 6RS Insulated Attic Radiation Shield 6RSA2 Insulated Wall Radiation Shield 6RSM Ins...

Page 30: ...Relining A Masonry Chimney 6 Diameter Listed to ULC S635M UL 1777 and ULC S640M at 2100 F Description Cat Part No 6 Length 6 Dia 6LL6 6LL6 12 Length 6 Dia 6LL12 6LL12 24 Length 6 Dia 6LL24 6LL24 36 Le...

Page 31: ...E MANUEL D INSTALLATION LES COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQUE DE 5mm D PAISSEUR POUR U...

Page 32: ...ct d damages repairs or inefficiency resulting from faulty installation or application of the Product IHP is not responsible for inadequate system draft caused by air conditioning and heating systems...

Page 33: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Page 34: ...See Page 28 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at pr...

Reviews: