Draco KVM Extender
62
2014-04-15
To deactivate the sample rate converter, write
SRC_NONE
in the
Config.txt file of the CPU unit.
Compatibility
AES/EBU, S/PDIF, EIAJ CP1201,
IEC 60958
Standards
Dolby Digital, DTS, PCM
Bit Depth
24 bit
Sample Rate
32 to 192 kHz
CPU Unit (Inputs)
Mini-XLR (AES/EBU; symmetrical,
lockable)
Coaxial (S/PDIF; RCA, Cinch)
Optical
(S/PDIF;
TOSLINK)
CON Unit (Outputs)
Mini-XLR (AES/EBU; symmetrical,
lockable)
Coaxial (S/PDIF; RCA, Cinch)
Optical
(S/PDIF;
TOSLINK)
Pos: 84 /806-IHSE/Technische Daten/Verbindungskabel/UEB_Verbindungskabel @ 5\mod_1279191107845_6.doc @ 43870 @ 2 @ 1
7.2
Interconnect Cable
Pos: 85 /806-IHSE/Technische Daten/Verbindungskabel/Verbindungskabel (Cat X) @ 5\mod_1278578406026_6.doc @ 42205 @ 3 @ 1
7.2.1 Cat X
A point-to-point connection is required. Operation with several patch fields
is possible. Routing over an active network component, such as an
Ethernet Hub, Router or Matrix, is not allowed.
Avoid routing Cat X cables along power cables.
If the site has 3-phase AC power, try to ensure that CPU Unit and
CON Unit are on the same phase.
To maintain regulatory EMC compliance, correctly installed shielded Cat X
cable must be used throughout the interconnection link.
To maintain regulatory EMC compliance, all Cat X cables need to carry
ferrites on both cable ends close to the device.