4.3.2 Parallel Operation (Stacking)
If you have special configurations, especially at installations with several
monitors per work station or additional support of USB 2.0 transmission
paths, the number of connectable CPUs and consoles can be increased
by a parallel operation (stacking) of several Draco tera devices.
One Draco tera matrix is defined as the
Master Matrix
and its IP address
entered into the
Master IP Address
field
(see Chapter 5.4.1, Page 77). All
other matrices are defined as
Sub Matrices
. Sub matrices must be
connected to the master matrix via network connector (RJ45) on the CPU
board. The
Enable LAN Echo
option has to be activated at the master
matrix
(see Chapter 5.4.1, Page 77).
If a switching command is performed using the OSD, the synchronized
matrices will also switch automatically.
Switching of stacked devices might be delayed by several seconds.