Draco tera
110
2014-04-15
Via right click on the macro list, macros of the selected key can be
copied into the cache by using the
Copy Key Macros
function. You
can paste the macros from the cache into a key by using the
Paste
Key Macros
function and you can reset all macros of the selected
key by using the
Reset Key Macros
function.
Pos: 75 /806-IHSE/Konfiguration/480_Extender-Einstellungen/480-xx @ 7\mod_1309938366618_6.doc @ 53197 @ 2 @ 1
5.6
Extender Settings
All extender units are managed in this menu. This includes the creation of
new extender units and the deletion of existing extender units.
The extender unit describes the connection of an physical extender to the
matrix. Every extender board with a direct cable connection to the matrix
is recognized as an extender unit. Dual-Head KVM extenders will be
recognized as two independent extender units.
KVM Extenders automatically create extender units inside the matrix.
You have the following options to access the menu:
You can select the following settings:
Field
Selection
Description
ID
Text
Numerical value of the extender ID
(KVM extenders: ID is provided by
extender unit (Serial No.) and cannot be
changed)
Name
Text
Name of the extender unit
activated
Create an extender unit with a fixed port
assignment (default)
Fixed
deactivated Function not active.
Port
1–288
(depending
on the
matrix)
Port number of the extender unit