Technical Data
Draco vario
DisplayPort
1.1
100
9.2.2 Fiber
NOTICE
Transmission problems
Routing over an active network component, such as an ethernet hub, switch, or router is not allowed.
Operation with several patch fields is possible.
Establish a point-to-point connection.
Avoid routing Cat X cables along power cables.
Type of Interconnect Cable*
Type of cable
Specification
Single-mode 9
μm
•
Two fibers 9
μm
•
I-V(ZN)H 2E9 (in-house patch cable)
•
I-V(ZN)HH 2E9 (in-house breakout cable)
•
I/AD(ZN)H 4E9 (in-house or outdoor breakout cable, resistant)
•
A/DQ(ZN)B2Y 4G9 (outdoor cable, with protection against rodents)
Multi-mode 50
μm
•
Two fibers 50
μm
•
I-V(ZN)H 2G50 (in-house patch cable)
•
I/AD(ZN)H 4G50 (in-house or outdoor breakout cable, resistant)
* Cable notations according to VDE
Maximum acceptable Cable Length
Type of cable
Maximum acceptable cable length
Single-mode 9
μm
10,000 m (32,808 ft)
Single-mode 9
μm XV
5,000 m (16,404 ft)
Multi-mode 50
μm
(OM3)
1,000 m (3,280 ft)
Multi-mode 50
μm
400 m (1,312 ft)
Using single-mode SFPs with multi-mode fibers, the ranges can be increased.
Type of Connector
Connector
Type
Plug-in connector
LC-Connector