background image

 Description 

2011-03-09 

17

 

3.6.7 

Model K477-1STC (USB 2.0 Cat X)  

CPU Unit 

CON Unit 

8

1

2

3

4

5

6

7

 

6

7

8

1

2

3

4

5

 

Rear View 

Front View 

Connect to 5VDC power  
supply 

Service port 1 

Connect to interconnect cable 1

To CPU: USB-HID 

To CPU: DVI-D  

Service port 2 

Connect to interconnect cable 2

To CPU: USB 2.0  

Connect to 5VDC power  
supply 

Service port 1 

Connect to interconnect cable 1

Connect to USB-HID devices  

Connect to DVI monitor  

Service port 2 

Connect to interconnect cable 2

Connect to USB 2.0 devices  

 
 

Pos: 17 /806-IHSE/Beschreibung/Geräteansichten/477-xx_COMP/1STM / -1STS (USB 2.0 Glasfaser)  @ 6\mod_1299603305359_6.doc @ 49208 @ 3 

 

Summary of Contents for Draco

Page 1: ...IHSE GmbH Maybachstrasse 11 88094 Oberteuringen Germany info ihse de www ihse de Tel 49 7546 9248 0 Fax 49 7546 9248 48 User Manual Edition 2011 03 09 Draco KVM Extender Model K477 Series ...

Page 2: ...ual the manufacturer assumes no liability for errors or omissions Neither does the manufacturer assume any liability for damages resulting from the use of the information contained herein The manufacturer reserves the right to change specifications functions or circuitry of the product without notice The manufacturer cannot accept liability for damage due to misuse of the product or due to any oth...

Page 3: ...12 3 6 2 Model K477 1SHM 1SHS Single Head Fiber 12 3 6 3 Model K477 1S4CA Analog Audio Serial 13 3 6 4 Model K477 1S4MA 1S4SA Analog Audio Serial 14 3 6 5 Model K477 1S4CD Digital Audio 15 3 6 6 Model K477 1S4MD 1S4SD Digital Audio 16 3 6 7 Model K477 1STC USB 2 0 Cat X 17 3 6 8 Model K477 1STM 1STS USB 2 0 Fiber 18 3 6 9 Model K477 1SHCV Single Head Cat X with VGA 19 3 6 10 Model K477 1SHMV 1SHSV...

Page 4: ... 3 Example Applications 32 5 Configuration 34 5 1 Transmission Parameters 34 5 2 DDC Settings 34 5 3 Command Mode 35 6 Operation 36 6 1 Download of DDC Information 36 7 Specifications 37 7 1 Interfaces 37 7 1 1 DVI D Single Link 37 7 1 2 DVI I Single Link 37 7 1 3 USB HID 37 7 1 4 USB 2 0 transparent 38 7 1 5 RJ45 Interconnect 38 7 1 6 Fiber SFP Type LC Interconnect 38 7 1 7 Serial Interface 39 7 ...

Page 5: ...D 52 8 3 Serial Connection 53 8 4 Analog Audio 53 8 5 Digital Audio 54 8 6 USB HID Add On 55 8 7 USB 2 0 56 9 Technical Support 57 9 1 Support Checklist 57 9 2 Shipping Checklist 57 10 Regulatory and Standards Compliance 58 10 1 CE Declaration Of Conformity 58 10 2 North American Regulatory Compliance 59 10 3 WEEE 59 10 4 RoHS 59 11 Glossary 60 Pos 1 806 IHSE Zu diesem Handbuch ATB_Zu diesem Handb...

Page 6: ...ode is printed on the base of the devices 1 3 Cautions and Notes The following symbols are used in this manual This symbol indicates an important operating instruction that should be followed to avoid any potential damage to hardware or property loss of data or personal injury This symbol indicates important information to help you make the best use of this product Pos 2 806 IHSE Sicherheitshinwei...

Page 7: ...d replacements Do not use a power supply if it appears to be defective or has a damaged case Connect all power supplies to grounded outlets In each case ensure that the ground connection is maintained from the outlet socket through to the power supply s AC power input Do not connect the link interface to any other equipment particularly network or telecommunications equipment Take any required ESD...

Page 8: ...X Twisted Pair interconnect cables or fiber interconnect cables The KVM Extender with Cat X interconnect cables is unsuitable for connection between buildings where a fiber optic based product should be used instead The KVM Extender with fiber interconnect cables can also be used with applications in environments which are difficult in electromagnetical aspects Electromagnetical interference can l...

Page 9: ... Unit and the CON Unit communicate with each other through the interconnect cables 1 2 4 5 7 6 3 System Overview 1 Source computer CPU 2 KVM Extender CPU Unit 3 Interconnect cable 4 KVM Extender CON Unit 5 Console monitor keyboard mouse 6 Second monitor option only with Dual Head devices 7 USB HID devices option only with 4x USB HID devices See Chapter 4 3 Page 32 for installation examples Pos 6 8...

Page 10: ...I Single Link up to 1920x1200 2x USB HID K477 2S4x Dual Head KVM Extender for 2x DVI D Single Link up to 1920x1200 4x USB HID Part numbers for Connections via Cat X or Fiber Cable All mentioned devices are available in the following versions Connection via Cat X cable x C Connection via Multi mode fiber cable x M Connection via Single mode fiber cable x S Part numbers for CPU Unit and CON Unit The...

Page 11: ...ead units Pos 8 806 IHSE Beschreibung Zubehör 477 xx_COMP 5 mod_1291120662750_6 doc 44582 2 3 5 Accessories Model Description 026 2A Serial cable 1 8 m RS232 247 U1 USB cable 1 8 m Type A to B 260 5U International power supply unit 100 240VAC 5VDC 4 A 436 AA VGA cable 1 8 m VGA to DVI I 436 ID DVI D cable 1 8 m DVI D 445 2X DVI D splitter cable 455 CK Stereo jack cable 1 6 m 3 5 mm Stereo 455 CR R...

Page 12: ...ble 4 Connect to USB HID devices 5 Connect to DVI monitor Pos 11 806 IHSE Beschreibung Geräteansichten 477 xx 1SHM _1SHS Single Head Glasfaser 5 mod_1278934861511_6 doc 42940 3 3 6 2 Model K477 1SHM 1SHS Single Head Fiber CPU Unit CON Unit 1 2 3 4 5 1 2 3 4 5 Rear View Rear View 1 Connect to 5VDC power supply 2 Service port 3 Connect to interconnect cable 4 To CPU USB HID 5 To CPU DVI D 1 Connect ...

Page 13: ... HID 1 5 To CPU DVI D 6 Connect to serial D Sub 9 7 Audio IN 8 Audio OUT 9 To CPU USB HID 2 1 Connect to 5VDC power supply 2 Service port 3 Connect to interconnect cable 4 Connect to USB HID devices 1 5 Connect to DVI monitor 6 Connect to serial D Sub 9 7 Audio IN 8 Audio OUT 9 Connect to USB HID devices 2 Pos 13 806 IHSE Beschreibung Geräteansichten 477 xx_COMP 1S4MA 1S4SA mit Analog Audio Seriel...

Page 14: ... 4 To CPU USB HID 1 5 To CPU DVI D 6 Connect to serial D Sub 9 7 Audio IN 8 Audio OUT 9 To CPU USB HID 2 1 Connect to 5VDC power supply 2 Service port 3 Connect to interconnect cable 4 Connect to USB HID devices 1 5 Connect to DVI Monitor 6 Connect to serial D Sub 9 7 Audio IN 8 Audio OUT 9 Connect to USB HID devices 2 Pos 14 806 IHSE Beschreibung Geräteansichten 477 xx_COMP 1S4CD mit Digital Audi...

Page 15: ...U USB HID 1 5 To CPU DVI D 6 RCA input 7 Mini XLR input 8 TOSLINK input 9 To CPU USB HID 2 1 Connect to 5VDC power supply 2 Service port 3 Connect to interconnect cable 4 Connect to USB HID devices 1 5 Connect to DVI monitor 6 RCA output 7 Mini XLR output 8 TOSLINK output 9 Connect to USB HID devices 2 Pos 15 806 IHSE Beschreibung Geräteansichten 477 xx_COMP 1S4MD 1S4SD mit Digital Audio 5 mod_129...

Page 16: ...ble 4 To CPU USB HID 1 5 To CPU DVI D 6 RCA input 7 Mini XLR input 8 TOSLINK input 9 To CPU USB HID 2 1 Connect to 5VDC power supply 2 Service port 3 Connect to interconnect cable 4 Connect to USB HID devices 1 5 Connect für DVI monitor 6 RCA output 7 Mini XLR output 8 TOSLINK output 9 Connect to USB HID devices 2 Pos 16 806 IHSE Beschreibung Geräteansichten 477 xx_COMP 1STC USB 2 0 Cat X 6 mod_12...

Page 17: ...USB HID 5 To CPU DVI D 6 Service port 2 7 Connect to interconnect cable 2 8 To CPU USB 2 0 1 Connect to 5VDC power supply 2 Service port 1 3 Connect to interconnect cable 1 4 Connect to USB HID devices 5 Connect to DVI monitor 6 Service port 2 7 Connect to interconnect cable 2 8 Connect to USB 2 0 devices Pos 17 806 IHSE Beschreibung Geräteansichten 477 xx_COMP 1STM 1STS USB 2 0 Glasfaser 6 mod_12...

Page 18: ...CPU USB HID 5 To CPU DVI D 6 Service port 2 7 Connect to interconnect cable 2 8 To CPU USB 2 0 1 Connect to 5VDC power supply 2 Service port 1 3 Connect to interconnect cable 1 4 Connect to USB HID devices 5 Connect to DVI monitor 6 Service port 2 7 Connect to interconnect cable 2 8 Connect to USB 2 0 devices Pos 18 806 IHSE Beschreibung Geräteansichten 477 xx_COMP 1SHCV Single Head Cat X mit VGA ...

Page 19: ...5 To CPU DVI I VGA DVI 6 Service port DVI I 7 IR receiver for remote control 1 Connect to 5VDC power supply 2 Service port 3 Connect to interconnect cable 4 Connect to USB HID devices 5 Connect to DVI monitor CPU Unit CON Unit 1 1 Front View Front View 1 IR receiver for remote control 1 IR receiver for remote control Pos 19 806 IHSE Beschreibung Geräteansichten 477 xx_COMP 1SHMV 1SHSV Glasfaser mi...

Page 20: ...USB HID 5 To CPU DVI I VGA DVI 6 Service port DVI I 7 IR receiver for remote control 1 Connect to 5VDC power supply 2 Service port 3 Connect to interconnect cable 4 Connect to USB HID devices 5 Connect to DVI monitor CPU Unit CON Unit 1 1 Front View Front View 1 IR receiver for remote control 1 IR receiver for remote control Pos 20 806 IHSE Beschreibung Geräteansichten 477 xx 2S4C Dual Head Cat X ...

Page 21: ...D 1 6 Service port 2 7 Connect to interconnect cable 2 8 To CPU USB HID 2 9 To CPU DVI D 2 1 Connect to 5VDC power supply 2 Service port 1 3 Connect to interconnect cable 1 4 Connect to USB HID devices 1 5 Connect to DVI monitor 1 6 Service port 2 7 Connect to interconnect cable 2 8 Connect to USB HID devices 2 9 Connect to DVI monitor 2 Pos 21 806 IHSE Beschreibung Geräteansichten 477 xx 2S4M_2S4...

Page 22: ...D 1 5 To CPU DVI D 1 6 Service port 2 7 Connect to interconnect cable 2 8 To CPU USB HID 2 9 To CPU DVI D 2 1 Connect to 5VDC power supply 2 Service port 1 3 Connect to interconnect cable 1 4 Connect to USB HID devices 1 5 Connect to DVI monitor 1 6 Service port 2 7 Connect to interconnect cable 2 8 Connect to USB HID devices 2 9 Connect to DVI monitor 2 Pos 22 806 IHSE Beschreibung Diagnose LEDs ...

Page 23: ...On or Flashing Connection failure flashing for about 20 s following a connection failure Flashing No connection via interconnect cable 2 Status LED green On Connection available LED 3 USB and Video Status LED color Description Dark Red Device ready Red Connection available Blue USB connection available Green Video available Yellow Connection and USB signal available no video Violet Connection and ...

Page 24: ... further multi color LED on the rear side for indication of the connection status CPU Unit CON Unit 1 1 Rear View Rear View LED 1 Digital Audio Status LED color Description Red No signal Cyan CPU Unit RCA signal available Violet CPU Unit XLR signal available Blue CPU Unit TOSLINK signal available Green CON Unit Signal available ...

Page 25: ...w Pos LED Status Description Off No USB HID device or not supported USB device connected Flashing fast USB HID device active 1 2 Device LED orange On USB HID device ready or KVM Extender in command mode Off No power supply voltage CPU Unit KVM Extender in command mode or no connection CON Unit Keyboard in command mode Flashing slowly CON Unit KVM Extender in command mode or no connection 3 Status ...

Page 26: ...r View Pos LED Status Description Off Connection available 1 Failure LED green On or Flashing Connection failure flashing for about 20 s following a connection failure Off No connection via interconnect cable 2 Status LED green On Connection available LED 3 USB 2 0 Status LED color Description Red Device ready Green Only connection available no USB 2 0 signal Green turquoise flashing Connection av...

Page 27: ...dia DVI Converter K238 5V Download CPU Unit 1 Front View LED 1 Connection Status VGA DVI I LED Farbe Description Dark Red No video signal monitor not detected Red Video signal not supported monitor not detected Green Video signal supported monitor not detected Blue No video signal monitor detected Violet Video signal not supported monitor detected Light Blue Video signal supported monitor detected...

Page 28: ...unit 2x country specific power cord Quick Setup DVI video cable 1 8 m DVI D male to male USB cable 1 8 m type A to type B Additional content for Dual Head devices DVI video cable 1 8 m DVI D male to male USB cable 1 8 m type A to type B Additional content for Analog Audio Serial option Serial cable 1 8 m RS232 male connector Stereo jack cable 1 6 m 3 5 mm male connector Additional content for Digi...

Page 29: ...tent for USB 2 0 Add On option USB cable 1 8 m USB type A to type B Additional content for VGA option replaces DVI D cable VGA cable 1 8 m VGA male to DVI I male Infrared remote control If anything is missing contact your dealer Pos 25 806 IHSE Installation System anschließen 477 xx_COMP 5 mod_1291123779531_6 doc 44749 233 ...

Page 30: ...s keyboard and mouse to the CON Unit 3 Connect the CON Unit with the interconnect cable s 4 Connect the 5VDC power supply to the CON Unit CPU Unit Installation 5 Connect the source computer CPU with the supplied cables to the CPU Unit Please ensure the cables are not strained 6 Connect the CPU Unit to the interconnect cable s 7 Connect the 5VDC power supply to the CPU Unit 8 Power up the system To...

Page 31: ...h the suitable audio input of the CPU unit 2 Connect the audio output of the CON Unit with suitable speakers or audio amplifiers If several active sources are connected Mini XLR input takes priority The audio signal is available at all outputs USB HID Add On Option 1 Connect the CPU with the CPU Unit USB HID 2 2 Connect the USB HID devices with the CON Unit Connect to USB HID devices 2 USB 2 0 Add...

Page 32: ... This section illustrates typical installations of KVM Extenders Pos 27 806 IHSE Installation Installationsbeispiele 477 xx_COMP 5 mod_1291124264328_6 doc 44767 1 2 4 5 3 KVM Extender Single Head 1 2 4 5 8 3 KVM Extender Single Head with Digital Analog Audio ...

Page 33: ...ble 4 KVM Extender CON Unit 5 Console monitor keyboard mouse 6 Second monitor option only with Dual Head devices 7 USB HID devices option only with 4x USB HID devices 8 Audio sink optional only with devices with Analog Audio Serial option or Digital Audio option Pos 28 806 IHSE Konfiguration UEB_Konfiguration 5 mod_1278575517073_6 doc 41846 1 ...

Page 34: ...t cases The download of the DDC information of the console monitor can be performed during normal operation see Chapter 6 1 Page 36 For special requirements DDC information can be retrieved and uploaded as a binary file at both the CPU Unit and the CON Unit Connect your computer with a USB Mini cable to the service port of the CPU Unit or CON Unit The data area of the unit is now accessible as a f...

Page 35: ...ed keyboard commands are available The following table lists the keyboard commands to enter and to exit Command Mode and to change the Hot Key sequence Function Keyboard Command Enter Command Mode default 2x Left Shift Hot Key Exit Command Mode Esc Change Hot Key sequence Left Ctrl Left Shift c Hot Key Code Enter Key Key Press keys simultaneously Key Key Press keys successively 2x Key Press key qu...

Page 36: ...DDC information of the console monitor via keyboard command under operating conditions 1 Enter Command Mode with the Hot Key see Chapter 5 3 Page 35 2 Press the key a to download the DDC information of the console monitor The screen goes black for a short time At the same time Command Mode is closed and the keyboard LEDs return to previous status The video mode has been readjusted Screen quality s...

Page 37: ...digital DVI signals that comply to DVI I Single Link norm can be transmitted This includes e g monitor resolutions such as 1920x1200 60Hz Full HD 1080p or 2K HD up to 2048x1152 Data rate is limited to 165 MPixel s Pos 38 806 IHSE Technische Daten Schnittstellen DVI x Single Link_HI_Interlaced 5 mod_1278928206636_6 doc 42780 Transmission of interlaced video signals such as 1920x1080i cannot be guar...

Page 38: ...orted with USB high speed max 480 Mbit s Each USB 2 0 port provides a maximum current of 500 mA high power Pos 41 806 IHSE Technische Daten Schnittstellen RJ45 Gerätekommunikation 5 mod_1278578339308_6 doc 42186 3 7 1 5 RJ45 Interconnect The communication of the Cat X devices requires a 1000BASE T connection Connector wiring must comply with EIA TIA 568 B 1000BASE T with RJ45 connectors at both en...

Page 39: ...direction Normally 4 of the 6 signals are handshake signals in addition to RxD and TxD The following configurations however can be realized using special adapter splitting cables Three single 2 wire transmissions Two transmissions with a handshake signal A serial mouse and a single 2 wire transmission In this case choose X ON X OFF software handshake for traffic control at printer and PC Connectio...

Page 40: ...ed with the microphone input of the sound card red Adjust the sound card to provide an additional amplification 20 dB The output of the CPU Unit is connected to the audio input of the sound card blue Choose this connection if the microphone has its own pre amplifier The CON Unit can do the pre amplification of the microphone as well Open the CON Unit locate the MIC jumper on the audio board and cl...

Page 41: ...the first active signal Up to three sinks can be connected to the CON Unit The signal is available at all outputs concurrently Compatibility AES 3 S PDIF EIAJ CP1201 IEC 60958 Standards Dolby Digital DTS PCM Scanning Frequency 32 to 48 kHz CPU Unit Inputs Mini XLR symmetrical lockable Coaxial RCA Cinch Optical TOSLINK CON Unit Outputs Mini XLR symmetrical lockable Coaxial RCA Cinch Optical TOSLINK...

Page 42: ...Type of Interconnect Cable The KVM Extender requires interconnect cabling specified for Gigabit Ethernet 1000BASE T The use of solid core AWG24 shielded Cat 5e or better is recommended Cat X Solid Core Cable AWG24 S UTP Cat 5e cable according to EIA TIA 568 B Four pairs of wires AWG24 Connection according to EIA TIA 568 B 1000BASE T Cat X Patch Cable AWG26 8 S UTP Cat 5e cable according to EIA TIA...

Page 43: ...e I AD ZN H 4G50 in house or outdoor breakout cable resistant Multi mode 62 5μm Two fibers 62 5μm I V ZN HH 2G62 5 in house breakout cable A DQ ZN B2Y 4G62 5 outdoor cable with protection against rodents Maximum Acceptable Cable Length Type of cable Maximum Acceptable Cable Length Single mode 9μm 10 000 m 32 800 ft Multi mode 50μm OM3 1 000 m 3 280 ft Multi mode 50μm 400 m 1 300 ft Multi mode 62 5...

Page 44: ...ce such as bar code scanners and touch screens may also be compatible It is not possible to guarantee support for all available USB HID devices In certain cases custom firmware may be required USB HID and other devices that are not supported as standard will normally operate with our devices featuring transparent USB support Please note that concurrent operation of more than two USB HID devices is...

Page 45: ...data 0 2 T M D S data 2 10 T M D S data 1 18 T M D S data 0 3 T M D S data 2 GND 11 T M D S data 1 GND 19 T M D S data 0 GND 4 n c 12 n c 20 n c 5 n c 13 n c 21 n c 6 DDC Input SCL 14 5VDC high impedance 22 T M D S clock GND 7 DDC Output SDA 15 GND 23 T M D S clock 8 Internal use 16 Hot Plug recognition 24 T M D S clock C1 Internal use C3 Internal use C2 n c C5 GND C4 Internal use Pos 55 806 IHSE ...

Page 46: ...21 n c 6 DDC Input SCL 14 5VDC high impedance 22 T M D S clock GND 7 DDC Output SDA 15 GND 23 T M D S clock 8 Internal use 16 Hot Plug recognition 24 T M D S clock C1 Internal use C3 Internal use C2 n c C5 GND C4 Internal use Pos 56 806 IHSE Technische Daten Pinbelegungen Buchse USB Typ B 5 mod_1278578750464_6 doc 42351 Connector USB Type B Picture Pin Signal Color 1 VCC 5VDC Red 2 Data White 3 Da...

Page 47: ...or 1 VCC 5VDC Red 2 Data White 3 Data Green 4 n c 5 1 5 GND Black Pos 59 806 IHSE Technische Daten Pinbelegungen RJ45 5 mod_1278578820011_6 doc 42405 RJ45 Picture Pin Signal Pin Signal 1 D1 5 D3 2 D1 6 D2 3 D2 7 D4 8 1 4 D3 8 D4 Pos 60 806 IHSE Technische Daten Pinbelegungen Glasfaser SFP Typ LC 5 mod_1278938501151_6 doc 43210 Fiber SFP Typ LC Picture Diode Signal 1 Data OUT 1 2 2 Data IN Pos 61 8...

Page 48: ...RTS 8 RxD 4 DSR 9 n c 1 5 6 9 5 GND Pos 63 806 IHSE Technische Daten Pinbelegungen Stereo Klinkenbuchse 3 5 mm 5 mod_1291128765156_6 doc 44901 3 5 mm Stereo Jack Plug Picture Pin Signal 1 GND 2 Audio IN OUT L 1 2 3 3 Audio IN OUT R Pos 64 806 IHSE Technische Daten Pinbelegungen RCA Cinch 5 mod_1291128877593_6 doc 44920 RCA Cinch Picture Pin Signal 1 GND 1 2 2 Data IN OUT Pos 65 806 IHSE Technische...

Page 49: ...nt per Unit Single Head devices max 800 mA Dual Head devices max 1 600 mA Optional Modules Analog Audio Serial max 300 mA Digital Audio max 300 mA USB HID max 300 mA USB 2 0 max 2 500 mA VGA max 900 mA Pos 68 806 IHSE Technische Daten Einsatzbedingungen ATB_Einsatzbedingungen 5 mod_1278578980026_6 doc 42480 2 7 6 Environmental Conditions Operating Temperature 41 to 113 F 5 to 45 C Storage Temperat...

Page 50: ... x 1 7 Shipping Box 460 x 250 x 120 mm 18 1 x 9 8 x 4 7 Pos 70 806 IHSE Technische Daten Transportgewicht 477 xx_COMP 5 mod_1291129453984_6 doc 45015 2 7 8 Shipping Weight Single Head Devices CPU Unit CON Unit 0 3 kg 0 7 lb Shipping Box 1 8 kg 4 0 lb Dual Head Devices and Devices with Optional Modules CPU Unit CON Unit 0 4 kg 0 9 lb Shipping Box 2 3 kg 5 1 lb Pos 71 806 IHSE Hilfe im Problemfall U...

Page 51: ...ed or yellow No video signal detected by source computer CPU Check DVI D cable to CPU Download DDC information from console monitors see Chapter 6 1 Page 36 Reboot CPU if necessary No monitor detected Check connection length and quality of the DVI D cable to monitor tighten cable thumbscrews CON Unit LED 3 red or yellow No video signal detected from CPU Unit Check connection length and quality of ...

Page 52: ...nother USB port if necessary Remove USB and power cable and restart CPU Connect power cable first CON Unit LED 3 green or violet Problems with USB connection Check connection of USB cable to USB HID device Remove DVI and power cable and restart CON Unit Connect power cable first No USB HID device Connect USB HID device USB device without function USB HID device is not supported Contact dealer if n...

Page 53: ... Possible Reason Measure No audio connection to CPU audio source Connect analog audio source Check audio cable No Signal Switch analog audio source on Activate analog output at CPU audio source CON Unit No signal at audio output No audio connection to audio sink e g speakers Connect analog audio sink and switch it on Check connection of audio cable No audio connection to audio source microphone Co...

Page 54: ...digital audio source on Activate digital output at CPU audio source No audio connection to audio sink e g speakers Connect digital audio sink Check connection of audio cable CON Unit LED 1 red No signal Check signal at CPU Unit No signal LEDs 1 OK Digital Silence at active audio source Check LEDs at CPU Unit Check audio format Change audio input Pos 77 806 IHSE Hilfe im Problemfall Störung am USB ...

Page 55: ...ealer if necessary CPU Unit LED 3 off Connection between CON Unit and CPU Unit Check interconnect cable and connectors CON Unit LED 3 off Keyboard in Command Mode Press Esc to leave Command Mode Connection between CON Unit and CPU Unit Check interconnect cable and connections CON Unit LED 3 flashing slowly Keyboard in Command Mode Press Esc to leave Command Mode Pos 78 806 IHSE Hilfe im Problemfal...

Page 56: ...onnect power cable first CON Unit LED 3 red Connection between CON Unit and CPU Unit Check interconnect cable and connectors No USB 2 0 device Connect USB 2 0 device CON Unit LED 3 flashing green turquoise and USB 2 0 device without function USB 2 0 device is not supported Check installation at the CPU also the necessary drivers New connection of the USB 2 0 device Contact dealer if necessary Pos ...

Page 57: ...he existing manual Nature circumstances and duration of the problem Involved components such as graphic source CPU OS graphic card monitor USB HID USB 2 0 devices interconnect cable including manufacturer and model number Results from any testing you have done 9 2 Shipping Checklist 1 To return your device contact your dealer to obtain a RMA number Return Material Authorization 2 Package your devi...

Page 58: ...quipment EN 55022 2006 A1 2007 Class A EN 55024 1998 A1 2001 A2 2003 This declaration certifies the conformity to the specified directives but contains no assurance of properties The safety instructions and installation guidelines noted in this manual shall be considered in detail Compliance with the specifications for cable lengths and types is mandatory Manufacturer IHSE GmbH Maybachstrasse 11 8...

Page 59: ...the party responsible for compliance could void the user s authority to operate the equipment Shielded cables must be used with this equipment to maintain compliance with radio frequency energy emission regulations and ensure a suitably high level of immunity to electromagnetic disturbances All power supplies are certified to the relevant major international safety standards Pos 83 806 IHSE Zertif...

Page 60: ...tionally also with USB 2 0 devices CPU Unit Component of a KVM Extender or Media Extender to connect to a source computer CPU DDC The Display Data Channel DDC is a serial communication interface between monitor and source computer CPU It allows a data exchange via monitor cable and an automatic installation and configuration of a monitor driver by the operating system Dual Access A system to opera...

Page 61: ...ctions RCA Cinch A not standardized plug connection for transmission of electrical audio and video signals especially with coaxial cables SFP SFPs Small Form Factor Pluggable are pluggable interface modules for Gigabit connections SFP modules are available for Cat X and fiber interconnect cables Single Head A system with one video connection Single Link A DVI D interface for resolutions up to 1920...

Page 62: ...ID device found is reported Typical HID devices include keyboards mice graphics tablets and touch screens Storage video and audio devices are not HID VGA Video Graphics Array VGA is a computer graphics standard with a typical resolution of 640x480 pixels and up to 262 144 colors It can be seen as a follower of the graphics standards MDA CGA and EGA Ende der Liste für Textmarke Inhalt ...

Reviews: