USING THE ON SCREEN MENU

Use the monitor and keyboard to use the main menu. 

To access the main menu:

1.  Make sure the extenders, the monitors and the computer are switched on.
2.   Press the 

ALT+GR

 key on your keyboard quickly five times.

      The 

main menu

 appears with an overview of the sub-menus. 

3  To open a sub-menu press the applicable key.

Main Menu

Main meu Short Cuts :
S  Status Overview 

Menu Status /current status

U  Update Flash FW 

Firmware Updates

F  Features Overview 

Settings  Features

D  DDC Option 

DDC Option Fix settings 1020 x 1080

L  Local Settings 

Settings Local

R  Remote Settings  

Settings Remote

A  About Overview 

Overview Upgrades Upgrades

L  Link Redundancy 
Q Exit

SYSTEM STATUS

Single 

Dual

In the status overview menu the current status of the extender connection is displayed. It 
provides information on the connection itself as well as resolution of the video channel, and USB-
status.

The enabled options and the current firmware-version is displayed in the left top corner.

Link status shows whether there is a physical connection available. 

Connected

 indicates if kvm 

data is currently able to be transmitted.

Video and USB 

show if data is currently being transmitted.

Summary of Contents for kvm-tec MASTERflex MV1 6012

Page 1: ...the local Unit Check if the DDC is set correctly in menu under point O Check if both Units have the correct firmware No Video Contact kvm tec support Check if all cables are plug ged in correctly Check if the PC is sending a Image by plugging in a monitor on the local out of the local Unit Check if local and re mote Unit have the correct firmware Check if the DDC is set correctly in the menu under...

Page 2: ...CAT5e 6 7 up to 150m 492ft redundant DVI out to Monitor Network cable CAT5e 6 7 up to 150m 492ft main link Audio from PC Audio to PC Audio to speaker Audio from microfone Power plug 12V 1A redundant Power plug 12V 1A redundant Delivery Content Delivery Content LOCAL CPU Unit LOCAL CPU Unit 1 x MA1 local CPU 1 x MA1 local CPU 1 x wall power supplyl 12V 1A INT or EU plug 1 x wall power supplyl 12V 1...

Page 3: ...iew Settings Features D DDC Option DDC Option Fix settings 1020 x 1080 L Local Settings Settings Local R Remote Settings Settings Remote A About Overview Overview Upgrades Upgrades L Link Redundancy Q Exit SYSTEM STATUS Single Dual In the status overview menu the current status of the extender connection is displayed It provides information on the connection itself as well as resolution of the vid...

Page 4: ... Diagnosis Diagnosis menu U Unlock Features Unlock Features I IP Management IP Management L Link Redundancy Alert redundanter Link POINT TO POINT You can switch the Point to Point mode on and off by pressing the P key ATTENTION if the point to point mode is activated the switching mode cannot be activated MATRIX SWITCHING MODE By pressing the M button you can switch the Matrix Switching Mode off a...

Reviews: