background image

Control Maintenance - 

continued

- Some of the controls have long shafts and feature a 

hex

style control

gland. These controls can be pulled out, exposing the shaft, Diagram C,

page 15. 

To lubricate the control, gently pull on the knob until the stainless steel

shaft is exposed. Lightly lubricate the shaft, then move the shaft in and

out several times. This will lubricate the x-ring in the Ikelite control gland.

This should be done before using the housing after a prolonged storage

period, or once a week when the housing is in constant use.

- Some of the controls have a short shaft and cannot be pulled out

exposing the shaft for lubrication. In the unlikely event one of these

controls sticks or becomes difficult to operate you can remove the

control from the housing and lubricate it, or return the housing to Ikelite

for maintenance. To remove the control, Diagram D, page 15, loosen the

set screw in the knob (allen wrench required); remove the knob. If there

is salt or dirt build-up on the exposed control shaft, clean the shaft.

Open the housing and gently slide the control shaft out of the control

gland. Clean and lightly lubricate the shaft, including the end of the

shaft.  Slide the shaft back into the control gland and gently slide the

shaft back and forth a few times without fully removing the shaft from the

gland. Replace the knob noting the flat area on the shaft. The set screw

in the knob should tighten down against the flat area on the control, so

the knob does not turn on the shaft.

Close housing 

without

a camera inside and water pressure test in a

bathtub or swimming pool. Rotate

*

the knobs to make sure the housing

is watertight and the gland was installed properly. Check all controls

while the housing is submerged.

*

Caution: 

If your housing has a shutter spring, 

DO NOT

rotate the

shutter control more than 1/16th of a rotation, otherwise, you may

accidentally bend the shutter spring or cause the spring to “pop off” the

control shaft.

14

Summary of Contents for 6183.34 Nikon P340

Page 1: ...6183 34 Nikon P340 Thank you for your purchase of Ikelite equipment Please read this instruction manual completely before attempting to operate or dive with this product Please refer to the back page...

Page 2: ...ash P 8 Closing the Housing P 8 Usage P 9 Final Check P 9 Zoom Control lever type only P 9 Deflector Purpose P 10 Deflector Removal Installation P 10 Diffuser Purpose P 10 Diffuser Installation Remova...

Page 3: ...install a camera Clean the housing main o ring and retest to make sure that it is watertight Refer to the Troubleshooting section page 17 Please read your camera manual thoroughly to have a full under...

Page 4: ...to 200 and AF area mode to Manual Normal Set Autofocus mode to AF S Single AF Set Noise Reduction filter to NR Normal and Built in ND filter to OFF Set Active D Lighting to OFF and Startup zoom positi...

Page 5: ...exposure compensation back away from your subject and zoom in When using an AF35 strobe turn the strobe power down If you own a white camera a reflection of the white camera lens may appear in some of...

Page 6: ...lash Mode Self timer UP 4 Rotary multi selector 5 Self timer LEFT Parts of the Housing Back View 6 1 5 3 2 7 6 9 8 10 4 Power Switch Note The Rotary multi selector 4 control has a cut out that will pr...

Page 7: ...a is secured to the housing back Position the camera on the tray 4 Using a coin or screwdriver preferred secure the camera with the tray mounting bolt which threads into the camera s tripod socket Dia...

Page 8: ...e sides of the housing should be closed at the same time Be sure they are down far enough to engage the lock Housing Back O ring Housing Back O ring Even gap on all four sides Housing Using the Camera...

Page 9: ...d to the center position to disengage If the housing zoom control is pushing the zoom lever in either direction you may not be able to take a picture or access other functions This is because the came...

Page 10: ...ock a portion of the light from the built in camera flash This can result in a shadow in a lower corner of the picture frame The Diffuser will help eliminate the shadow In addition you can zoom in if...

Page 11: ...glass or acrylic in the lens port as a camera lens After use rinse and gently dry the outside lens port to avoid water spotting To clean use a mild soap solution or lens cleaner Do not rinse the insi...

Page 12: ...pply a thin coating of lubricant Only apply enough lubricant to make the o ring feel slick Do Not stretch the o ring This light coating of lubricant will help to keep the o ring from drying out and wi...

Page 13: ...several times until the lube is worked up into the o ring In the unlikely event one of the control shafts sticks or becomes difficult to operate you can remove the control from the housing and lubrica...

Page 14: ...osen the set screw in the knob allen wrench required remove the knob If there is salt or dirt build up on the exposed control shaft clean the shaft Open the housing and gently slide the control shaft...

Page 15: ...ft before reinserting into gland Diagram B O rings Knob Control Gland Housing Lubricate shaft Pull out knob to expose shaft Diagram C Diagram D Loosen set screw allen wrench required Tighten set screw...

Page 16: ...down on subjects as they will quite often blend into the background and be difficult to see in the photograph Shoot subjects straight on or shoot up at a slight angle using the blue water as a contras...

Page 17: ...Maintenance section pages 13 15 Return housing to Ikelite for routine maintenance Problem Solution Image is over underexposed or a corner of the image is dark Check that the camera flash or strobe is...

Page 18: ...condense any trapped moisture forming fog on the lens port Close the housing in an air conditioned room or vehicle or in front of an air conditioner The housing should not be in direct sunlight for a...

Page 19: ...mera installed and pressure test or take diving Return housing to Ikelite for evaluation Problem Solution Pictures are too blue or too green Use custom manual white balance if available Reset for each...

Page 20: ...rate external strobe adds color to restore the warmer colors filtered out by the water as well as to illuminate the subject Add a second strobe to eliminate shadows and evenly light your subjects Vide...

Page 21: ...use only Not recommended when using external strobes UR Pro Filter Lens Port Bayonet mount lenses cannot be used with this housing External Accessory Lenses Please visit www ikelite com for additional...

Page 22: ...Service Department 50 West 33rd St Indianapolis IN 46208 USA Email ikelite ikelite com Phone 317 923 4523 This Ikelite product is warranted against any manufacturing defects for a period of one 1 yea...

Page 23: ...ll products perform as intended Evidence of purchase date must be provided to obtain warranty service No prior authorization is required You may return directly to us or through your dealer Please inc...

Page 24: ...elite Underwater Systems 50 West 33rd Street Indianapolis IN 46208 USA www ikelite com Product Registration Please go to www ikelite com to register your Ikelite housing within 15 days of purchase 201...