background image

DS125 

Substrobe DS125 Front 

Modeling 

Light 

Flash 

Tube 

Flash 

Diffuser 

Protruding 

Ear 

Holes 

for Lanyard 

Tab 

Cut-out 

Hole for 

Diffuser 

Lanyard 

88

M

MO

ODDEELLIIN

NGG  LLIIGGH

HTT

DS125 

Electrical 

Pins 

Bulb Holder Stem 

(unscrew to remove) 

77

O

OPPEEN

NIIN

NGG  AAN

NDD  CCLLO

OSSIIN

NGG

Always turn the Substrobe OFF before opening the strobe.

O

OPPEEN

NIIN

NGG  TTH

HEE  SSTTRRO

OBBEE ____________________________________________________________________________________________

Turn the strobe OFF, and place the strobe face down on a flat surface.
Slide the locking lever out by either grasping the sides of the lever and pulling it out

OR use your thumb to apply slight pressure to the top of the lever and slide it out.

Flip the lever up and then rotate the lever counter-clockwise 90°. The internal

spring automatically pushes open the strobe. Lift the rear section off of the strobe front.

The rear section is the NiMH battery pack for the strobe.

The rear NiMH pack does NOT remain waterproof when removed from the strobe.

Therefore, we suggest keeping the open portion of the NiMH pack pointed down while

removing to eliminate the possibility of water droplets falling inside. The NiMH batteries

remain permanently secured inside the pack.

The front section of the DS125, which houses the main electronics, is safely sealed

separately from the NiMH pack. The front section will remain waterproof when the

NiMH pack is removed. However, avoid salt-water contact with the battery pins.

Damage/corrosion can cause short circuiting. 

D

DO

O  N

NO

OTT

disassemble the strobe or the

NiMH pack. We suggest storage of your strobe with the locking lever OPEN to allow

any hydrogen/air mixture

to escape.

O

O--RRIIN

NGG __________________________________________________________________________________________________________________________

The o-ring is located on the inside rim of the NiMH pack. Keep the o-ring and the

sealing surfaces clean. 

D

DO

O  N

NO

OTT

stretch the o-ring when cleaning. It is not necessary to

lubricate the o-ring. Never use spray lubricant because it may crack the plastic.

RREECCH

HAARRGGEE  TTH

HEE  BBAATTTTEERRIIEESS ____________________________________________________________________________________

See "NiMH Pack" section for recharging information.

CCLLO

OSSIIN

NGG  TTH

HEE  SSTTRRO

OBBEE ______________________________________________________________________________________________

Make sure the power switch has been rotated to the off position.
Place the front of the strobe face down on a flat surface. Check that the o-ring and

sealing surfaces are clean; make sure the o-ring is positioned properly inside the rim of

the NiMH pack. Place the locking lever in the open position (slide the lever out, flip the

lever up, and rotate the lever counterclockwise).

Align the front and rear sections of the strobe. Lower the NiMH pack onto the front

section of the strobe. Proper alignment of the two sections is extremely important to

avoid possible damage to the internal components.

To seal the strobe, simply press down slightly on the rear of the NiMH pack and

rotate the lever clockwise. Flip the lever down and then slide the lever in to the locked

position to properly seal the strobe.

Summary of Contents for DS-125

Page 1: ...nos 1 5mm or SLR 20mm with diffuser G Gu ui id de e N Nu um mb be er r I IS SO O 1 1 0 00 0 f fe ee et t 64 surface 32 underwater G Gu ui id de e N Nu um mb be er r I IS SO O 1 1 0 00 0 m me et te er rs s 20 surface 1 0 underwater F Fi ir ri in ng g M Mo od de es s TTL Auto Manual 1 2 M 1 4 M 1 8 M Slave featuring auto exposure using optional DS Sensor 41 00 5 Slave featuring 1 0 manual power sett...

Page 2: ...sual ready light indicates when strobe has recycled Female Ikelite bulkhead connector accepts different camera sync cords the Ikelite DS Sensor 41 00 5 or EV Controller 41 00 6 Exposure guide label references recommended exposure settings Separate diffuser provides softer lighting and wider coverage angle Strobe mount accommodates most Ikelite arm systems B BE EC CO OM MI IN NG G F FA AM MI IL LI ...

Page 3: ...e has provided proper exposure This green confidence light illuminates only in the TTL exposure mode F FI IR RI IN NG G M MO OD DE E S SW WI IT TC CH H_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Multiple firing modes are featured TTL Auto and four manual power settings Full 1 2 1 4 and 1 8 T TT TL L A...

Page 4: ...the strobe or the NiMH pack We suggest storage of your strobe with the locking lever OPEN to allow any hydrogen air mixture to escape O O R RI IN NG G _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ The o ring is located on the inside rim of the NiMH pack Keep the...

Page 5: ...ch is in the TEST position It is normal for the modeling light to flicker every few seconds as the strobe capacitors recharge The momentary power drain on the batteries causes the flickering as the strobe recycles B BU UL LB B_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _...

Page 6: ...rds the Smart Charger will automatically switch to provide a trickle maintenance charge Only the Smart Charger is capable of providing a trickle maintenance charge permitting the NiMH pack to be continuously charged for extended periods C CO ON NT TI IN NU UO OU US S i il ll lu um mi in na at te ed d l li ig gh ht t Indicates that the NiMH module is being quick charged S SL LO OW W B BL LI IN NK K...

Page 7: ...uence too quick for the Ikelite DS Sensor to identify proper auto exposure and the Ikelite EV Controller 41 00 6 would then be recommended instead For maximum control using manual exposure choose the optional Ikelite EV Controller 41 00 6 which connects to the DS1 25 strobe and provides 1 0 manual power settings in half stop increments The EV Controller can be triggered using the built in slave se...

Page 8: ...e Substrobe has recycled and is ready to fire If the Ikelite housing does not feature TTL compatible circuitry then the ready light in the camera viewfinder would not be triggered when the strobe has recycled T Tr ri ig gg ge er re ed d v vi ia a S Sl la av ve e S Se en ns so or r When using the DS1 25 strobe with the optional DS Sensor or EV Controller without optional sync cord the strobe is not...

Page 9: ...e camera D DO O N NO OT T leave the sync cord or sensor connected to the strobe for prolonged periods as electrolysis can make removal impossible D DO O N NO OT T disconnect the sync cord or sensor from the strobe while underwater or when wet Connections are NOT waterproof when not connected C CO ON NN NE EC CT TI IO ON N T TO O S ST TR RO OB BE E_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _...

Page 10: ... __ __ __ __ __ __ __ _ 4 41 10 03 3 5 51 1Single strobe cord 4 41 10 03 3 5 52 2 Dual strobe cord These cords connect Ikelite Substrobes to Ikelite camera housings Use TTL Auto or manual exposure modes C Co on nn ne ec ct t I Ik ke el li it te e H Ho ou us si in ng g 1 Make sure all components are dry Clean and lightly lubricate the stem o ring and the housing connector threads Check the o ring f...

Page 11: ...fuser so the tabs on the front lock the diffuser in place 3 To remove the diffuser rotate the diffuser so the cut outs align with the tabs on the front Grasp the protruding ears on the diffuser to remove 4 A lanyard can be attached to the diffuser by threading it thru the two circular openings on the diffuser U US SE E O OF F T TH HE E D DI IF FF FU US SE ER R_ __ __ __ __ __ __ __ __ __ __ __ __ ...

Page 12: ...atured on the DS1 25 and secures to most Ikelite arm systems The paddle type mount is required for compatibility with the arm 4075 1and it allows the strobe to tilt forward and backward The rubber gasket on the strobe mount creates friction against the arm and should NOT be lubricated Remove wing nut from strobe mount Place the top of the arm against the rubber gasket on the strobe mount Replace t...

Page 13: ..._ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ The stem protruding at the base of the arm snaps into the release handle on the Ikelite housing The stem also provides a convenient location for securing the optional DS Slave Sensor or EV Controller Insert the stem into the release handle Depress the handle s release button and slide the stem fully into the receptor Release the button and it should...

Page 14: ...er settings in half stop increments The EV Controller can be triggered using the built in slave sensor or an optional sync cord can be connected Always carry spare batteries Weak batteries cause many camera and strobe problems Prolong the battery life by recharging the NiMH monthly even when not used Do not discharge the NiMH completely as this can cause permanent damage R RA AP PI ID D U US SE E_...

Page 15: ...ogen air mixture to escape 2 Always rinse the exterior of the Substrobe with fresh water after use The strobe can be cleaned by soaking it in a mild soapy solution Use liquid soap RINSE and DRY the strobe before storage 3 The o ring 01 32 36 is located on the inside rim of the DS1 25 battery pack Keep the o ring and the sealing surfaces clean D DO O N NO OT T stretch the o ring when cleaning It is...

Page 16: ...including but not limited to bulb failure are not covered Except as mentioned above no other warranty expressed or implied applies to this Ikelite product We recommend adding an ALL RISK floater to your homeowner s insurance policy in the event you damage flood or lose your camera or strobe Ikelite warranty does NOT cover customer neglect R RE ET TU UR RN NI IN NG G P PR RO OD DU UC CT TS S F FO O...