background image

13

Substrobe 
DS125

EV Controller

Ball Socket
Arm

O

Oppttiioonnaall AAcccceessssoorriieess
SSuubbssttrroobbee D

DSS112255 PPaacckkaaggee 

#

#33994444..7777

The Substrobe DS125 package

includes the Substrobe DS125, the EV

Controller, ball socket arm and

charger. The EV Controller provides

10 manual power settings in 1/2 stop

increments. An external strobe offers

several advantages over using the

camera’s built-in flash. External

strobes move the flash away from

the camera lens which helps reduce

backscatter. They also expand

lighting options to achieve the best

lighting for different subjects. A

second external digital strobe

package can be added to fill the

shadows and produce more realistic

photographs.

The Substrobe DS125 covers the

equivalent of a 18mm lens, 100

degrees. It is the ideal choice when

using accessory wide angle lenses

greater than 28mm. 

N

NO

OTTEE::

Optional Tray and

Release Handle

required to mount

Substrobes.

14

M

Maaiinntteennaannccee

The Ikelite Digital Housing should be given the same care and

attention as your other photographic equipment. In addition to

normal maintenance we recommend that the housing be returned

to Ikelite periodically to be checked and pressure tested.

1. D

Doo N

Noott leave the camera and housing in direct sunlight for

prolonged periods. Heat may damage the camera.

2. D

Doo N

Noott ship the camera in the housing.

3. Before using the housing, always check the tightness of the sseett

ssccrreew

w in each control knob. 

Check each ccoonnttrrooll ggllaanndd penetrating the housing to make sure

they are tight. There is a slight chance that either could vibrate

loose during travel.

4. Keep the back o’ring clean and lightly lubricated. To lubricate

remove the o’ring from the back. Put a small amount of lkelite

lubricant on your fingers. Draw the o’ring through your fingers

to apply a light coating of lubricant. Only apply enough

lubricant to make the o’ring feel slick. D

Doo N

Noott ssttrreettcchh tthhee oo’’rriinngg.

This light coating of lubricant will help to keep the o’ring from

drying out and will help to show a dark sealing line when the

housing back is properly sealed.

5. Keep the area where the o’ring fits and the sealing surface of

the housing clean.

6. Rinse the housing exterior thoroughly in fresh water after each

salt water use. Dry with a soft cloth. Dry lens port to eliminate

water spotting.

After several uses in salt water soak the housing exterior in a

mild soap solution, rinse and dry before storage. When storing

the housing, remove the back o’ring, lightly lubricate and place

in a plastic bag. Place the plastic bag with o’ring inside the

housing for safe keeping. 

CCAAU

UTTIIO

ON

N

N

Neevveerr uussee sspprraayy lluubbrriiccaannttss aass tthhee pprrooppeellllaanntt iinnggrreeddiieenntt ccaann

c

caauussee tthhee ppllaassttiicc hhoouussiinngg ttoo ccrraacckk..

15

CCoonnttrrooll M

Maaiinntteennaannccee 

Ikelite controls are designed to provide years of reliable service

with minimal maintenance.

1. Push button controls require no maintenance other than rinsing

in fresh water after saltwater use. If a push button control

becomes difficult to push or if it sticks when depressed, soak the

housing in luke warm fresh water. After a few minutes operate

the push button. If this does not correct the problem, return the

housing to Ikelite for maintenance.

2. Some of the controls have long shafts. These controls can be

pulled out, exposing the shaft (see drawing). 

To lubricate the control, gently pull on the knob until the

stainless steel shaft is exposed. Lightly lubricate the shaft, then

move the shaft in and out several times. This will lubricate the

x’ring in the Ikelite control gland. This should be done before

using the housing after a prolonged storage period, or once a

week when the housing is in use.

housing

lubricate shaft

pull out to
expose shaft

16

CCoonnttrrooll M

Maaiinntteennaannccee CCoonntt..

3. Some of the controls have a short shaft and cannot be pulled

out exposing the shaft for lubrication. In the unlikely event one

of these controls sticks or becomes difficult to operate you can

remove the control from the housing and lubricate it, or return

the housing to Ikelite for maintenance. To remove the control,

loosen the set screw in the knob (allen wrench required);

remove the knob. If there is salt or dirt build-up on the exposed

control shaft, clean the shaft. Open the housing and gently slide

the control shaft out of the control gland. Clean and lightly

lubricate the shaft, including the end of the shaft. Slide the

shaft back into the control gland and gently slide it back and

forth a few times without fully removing the shaft from the

gland. Replace the knob, NOTE the flat area on the shaft, the

set screw in the knob should tighten down against the flat area

on the control so the knob does not turn on the shaft.

Loosen set screw
(allen wrench required)

Flat

Tighten set screw down

against this area when

replacing the knob.

housing

gland

control
shaft

Lubricate end of shaft
before reinserting into
gland

Summary of Contents for DSC-W90

Page 1: ...ll le er r The EV Controller used with Ikelite DS Substrobes have two user settings One setting is for strobe selection the other is for pre flash or non pre flash T Th hi is s c ca am me er ra a u us se es s p pr re e f fl la as sh h thus the EV Controller should be set to the pre flash position when used with this camera 3 Front View Shutter Release Lid Snap Zoom Mode Control Button Menu Playbac...

Page 2: ...e ec ck k Once the housing is closed check the o ring seal Check the gap between the housing back and the housing it should be even all the way around Look through the clear plastic back at the o ring You should see a darkened area where the o ring is compressed against the housing back If you do not see an even black compression seal all the way around the back open the lid snaps reseat the housi...

Page 3: ...ently dry the lens port to avoid water spotting To clean use a mild soap solution or lens cleaner Do not use alcohol or window cleaner on the Lens Port The Lens Port will accept 2 Wide Angle Adapters The Wide Angle Adapter 9306 80 which is required to mount the Inon UWL 1 50AD Bayonet style wide angle lens The Wide Angle Adapter 9306 81is required to mount the 6420 Ikelite W 20 Wide Angle Lens and...

Page 4: ...ng exterior in a mild soap solution rinse and dry before storage When storing the housing remove the back o ring lightly lubricate and place in a plastic bag Place the plastic bag with o ring inside the housing for safe keeping C CA AU UT TI IO ON N N Ne ev ve er r u us se e s sp pr ra ay y l lu ub br ri ic ca an nt ts s a as s t th he e p pr ro op pe el ll la an nt t i in ng gr re ed di ie en nt ...

Page 5: ...e light path between the strobe and the subject 18 P Ph ho ot to o T Ti ip ps s 1 The number one rule in underwater photography is eliminate as much water between camera and subject as possible Get as close as you can to the subject then use the zoom If you are using flash subjects beyond 6 feet 1 8m will not have much color 2 The camera s built in flash is very close to the camera lens The flash ...

Reviews: