background image

8

D

Diiffffuusseerr &

& D

Deefflleeccttoorr IInnssttaallllaattiioonn

Housing shown with

deflector installed.

Deflector

U

Ussiinngg FFllaasshh
U

Ussiinngg tthhee CCaam

meerraa’’ss BBuuiilltt--iinn FFllaasshh..

If you do not have an external flash the camera’s built-in flash

can be used. See Diffuser instructions.

NOTE: The camera’s built-in flash cannot be used with optional

Wide-angle lenses.

9

D

Diiffffuusseerr aanndd D

Deefflleeccttoorr ccoonntt..

A diffuser and deflector are

included with the housing. The

diffuser is white transparent

plastic. The deflector is also white

but is not transparent and has a

decal on the front.

To install the diffuser or deflector

spread the port clamp at the spring

end and slide over the lens port.

The white plastic should be placed

in front of the camera flash. The

port clamp should be pushed back

against the front  of the housing.

D

Diiffffuusseerr

The diffuser should be installed when using the camera’s built in

flash. When shooting with the camera’s built-in flash at

approximately 2 feet (0.6 m) or less, the lens port on the

housing blocks a portion of the light from the camera’s built-in

flash, creating a shadow in the lower left of the photo. To

eliminate the shadow zoom the lens between 1/3 and 1/2 of its

full telephoto range. 

(You can test this above water)

D

Deefflleeccttoorr

The deflector should be installed when using an external strobe

such as the DS51 or DS125 Substrobe and EV Controller. The

deflector will redirect the camera’s flash to the EV Controller

which controls the external strobes output.

Diffuser/
Deflector 
material

Port Clamp

Spring

Spread to Install

10

LLeennss PPoorrtt

Treat the glass in the lens port as a camera lens. After use, rinse

and gently dry the lens port to avoid water spotting. To clean

use a mild soap solution or lens cleaner.
Do not use alcohol or window cleaner on the Lens Port.
The Lens Port will accept (2) Wide-Angle Adapters. The Wide-

Angle Adapter #9306.80 which is required to mount the Inon

UWL-150AD Bayonet style wide-angle lens. The Wide-Angle

Adapter 9306.81 is required to mount the following Wide-Angle

Lenses, Inon UWL-100, Sea&Sea #58070 and Ep0que DCL-20

screw thread (67mm) style wide-angle lenses.

These lenses can be secured onto the Wide-Angle Adapter

above or below water as they are designed to have water

between the front of the port and the accessory lens. Make sure

no air bubbles are trapped between the port and the accessory

lens. Any vignetting that occurs can be eliminated by zooming

the camera lens slightly. The camera’s built-in flash cannot be

used with wide angle

lenses. The front of the

lenses are so large they

block  the camera’s flash.

To properly light subjects

when using a wide angle

lens an external strobe

should be used. Due to

the wide-angle of

coverage of these lenses,

the DS125 Substrobe is

recommended or two

DS51 Substrobes.

Wide-Angle Lens

Wide-Angle Adapter

11

O

Oppttiioonnaall AAcccceessssoorriieess
BBaacckk O

O’’rriinngg 

##00111100

O’rings last for several years if properly maintained. (See

maintenance) Always carry a spare.

U

URR//PPrroo FFiilltteerr 

##66444411..3322

The UR/Pro underwater color correcting filter is designed to

restore some of the warm colors filtered out by the water. For

available light use only, not recommended for use with flash.

D

Duuaall H

Haannddllee TTrraayy 

##99552233..1122

A Dual Handle Tray is available. The Dual Handle Tray provides

a second access point for mounting a second strobe.

SSuubbssttrroobbee PPaacckkaaggeess AAvvaaiillaabbllee

#3944.45 DS51, Sync Cord, Strobe Arm Is

#3944.51 DS51, Sync Cord, Strobe Arm SA-100R

#3944.75 DS125, Sync Cord, Strobe Arm SA-100R Smart Charger

U

Ussiinngg EExxtteerrnnaall FFllaasshh iinn M

Maannuuaall M

Mooddee

To use any power settingbs on an external flash in it’s manual

mode the camera’s flash mode must be set to “Slave Mode”.

In the camera’s menu set-up go to flash mode and select

“Slave Mode”. If Slave Mode is not selected most images will

be underexposed.

Summary of Contents for Olympus SP-350

Page 1: ...Digital Housing i n s t r u c t i o n m a n u a l f o r Olympus SP 350 H o u s i n g 6132 35 ...

Page 2: ...ve lubricant can collect sand and dirt which may interfere with proper sealing C CA AU UT TI IO ON N N Ne ev ve er r u us se e s sp pr ra ay y l lu ub br ri ic ca an nt ts s a as s t th he e p pr ro op pe el ll la an nt t i in ng gr re ed di ie en nt t c ca an n c ca au us se e t th he e p pl la as st ti ic c h ho ou us si in ng g t to o c cr ra ac ck k O Op pe en ni in ng g t th he e H Ho ou us s...

Page 3: ...l S St tr ro ob be es s When using an external strobe connect the housings Hot Shoe Connector slide the connector into the hot shoe of the camera from the back of the camera as shown Slide the connector forward until it stops This can be done after the camera is secured with the mounting bolt N NO OT TE E Even if you are not using an external strobe it is recommended that you slide the housings Ho...

Page 4: ... accept 2 Wide Angle Adapters The Wide Angle Adapter 9306 80 which is required to mount the Inon UWL 150AD Bayonet style wide angle lens The Wide Angle Adapter 9306 81 is required to mount the following Wide Angle Lenses Inon UWL 100 Sea Sea 58070 and Ep0que DCL 20 screw thread 67mm style wide angle lenses These lenses can be secured onto the Wide Angle Adapter above or below water as they are des...

Page 5: ...y y l lu ub br ri ic ca an nt ts s a as s t th he e p pr ro op pe el ll la an nt t i in ng gr re ed di ie en nt t c ca an n c ca au us se e t th he e p pl la as st ti ic c h ho ou us si in ng g t to o c cr ra ac ck k 12 Substrobe DS51 SA 100Q Ball Socket Arm O Op pt ti io on na al l A Ac cc ce es ss so or ri ie es s S Su ub bs st tr ro ob be e D DS S5 51 1 P Pa ac ck ka ag ge e 3 39 94 44 4 5 54 4...

Page 6: ...hat it is properly sealed 4 Next check to see if there are any bubbles on the face of the lens port If there are take your finger and remove them If there are bubbles on the lens port they can produce soft focus spots in your photographs 5 If you use the housing Zoom control make sure to move it back to the center position If the housing Zoom control is pushing the camera zoom lever to either side...

Page 7: ...gainst any manufacturing defects for a period of one 1 year from the date of purchase Defective products should be returned prepaid to Ikelite Ikelite will at its discretion repair or replace such products and will return to customer prepaid All other claims of any nature including but not limited to bulb failure are not covered Except as mentioned above no other warranty expressed or implied appl...

Reviews: