10
-
Visually inspect the compressor every 3 months (oil leakages, tightness of parts etc.).
-
Retighten the cylinder cover to 27 Nm after approximately the first 5 hours of use while the
machine is cold.
-
Change the oil after the first 50 hours of use and after that every 500 hours of use or at least
once a year. Use only synthetic oil – oil capacity 0,9 l.
-
Always empty the tank from pressure after use.
-
AVOID USING EXTENSION CORD!
COMPONENTS (see pictures on page 2)
Operating pressure control unit
-
Components from left to right: water separator, regulator, quick coupling (outlet for purified
air), oiler and quick coupling (outlet for purified and oiled air).
-
Use oil which is suitable for pneumatic tools in the oiler, for example Viima Air tool oil (ISO
VG32).
-
Pneumatic tools usually operate at 6,5 bar pressure. Do not use higher pressure as it may dam-
age the pneumatic tool.
Pressure switch
-
The pressure switch operates automatically; the compressor switches off after reaching the pres-
sure of 8 bars and switches on again after the pressure has dropped to 6 bars, so the difference
between upper and lower pressure is approximately 2 bars. If you want to increase the upper
pressure, the lower pressure will automatically be approximately 2 bars lower.
-
If you need higher pressure in your work, contact your dealer. The use of any higher pressure is
not recommended as it reduces the operating life of the compressor and is considered as normal
wear and tear which is not covered by the warranty.
-
The pressure switch includes a low-voltage protection which protects the motor in case of volt-
age drop, for example
•
when using long extension cords or extension cords that are in poor shape
•
when the compressor is used in cold conditions
•
if the compressor has not been turned off by the switch
•
if other appliances with high current need are connected to same power supply.
-
The low-voltage protection is reset by the current switch.
-
If the low-voltage protection trips often, check the above mentioned possible causes or contact
your dealer.
Overload protection
-
The overload protection protects the motor from overloading, for example if the pneumatic tool
needs a lot of compressed air in long-term use, in which case the compressor can not stop and
cool off, or if the voltage has risen too high which is common when using an aggregate.
-
The overload protection is reset by the button in figure 3.
Mechanic half-compression device in the condenser unit
-
To be used mechanically in cold conditions. Releases pressure channel so that motor can start
more easily while the block is rotating free. Close the cock after the motor has reached full
speed and pressure will start to form inside the tank.
-
Use only when necessary!
Rear handle
-
With the rear handle the compressor is easy to lift for example into a car. It can also be used for
binding the compressor during transport. Furthermore, the rear handle protects the tank pressure
outlet and also functions as a handy reel for the cable.
1
2
5
4
3
Summary of Contents for XTTURBO
Page 2: ...2 1 2 6 5 4 7 8 3...