Summary of Contents for MuteClip

Page 1: ... ikoustic com Creating Quieter Spaces Together Creating Quieter Spaces Together MuteClip Installation Guides Wall 02 To Stud Wall 04 Direct to Wall 06 Windows Doors Openings and Pitched Ceilings Ceiling 08 Direct to Concrete Ceiling 10 To Battened Concrete Ceiling 12 To Wooden Joist Ceiling 15 MuteClip XP 17 MuteClip LP ...

Page 2: ...n be friction held between the joists battens if required use thin wiring to keep it suspended Measure up and mark out the appropriate locations for the MuteClips See configurations or contact iKoustic for appropriate dimensions The perimeter MuteClips must be no further than 100mm from the adjacent surfaces MuteClips to be spaced a maximum of 600mm apart vertically MuteClip to Stud Frame 1st Plas...

Page 3: ...rect contact with any adjacent surfaces There should be a 2 5mm gap around the perimeter of the surface Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your second layer of Acoustic Plasterboard stagger the joist ...

Page 4: ...nto brickwork to secure the MuteClip Drill hole in the wall plug this hole and fix the screw through the Clip into the hole MuteClips to be spaced a maximum of 600mm apart vertically MuteClip centres to vary betwen 600 and 1200m centres creating a Diamond configuration See configurations or contact iKoustic for appropriate dimensions Attach MuteClip Channels into MuteClips channels must run horizo...

Page 5: ...ust be a 2 5mm gap around the perimeter of the room Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your second layer of Acoustic Plasterboard and stagger the joins from the first layer making sure that the screws...

Page 6: ... window to ensure the plasterboard is supported along the edge Perimeter Details MuteClip Installation Guide Wall Windows Doors Openings and Pitched Ceilings Windows and Doors Please contact iKoustic to confirm correct configurations appropriate for your system If you need any assistance please call us on 01937 588 226 MuteClip Stud System Window Side View MuteClip Stud System Door Top View MuteCl...

Page 7: ...is supported along the edge MuteClip Installation Guide Wall Windows Doors Openings and Pitched Ceilings Pitched Ceilings Please contact iKoustic to confirm correct configurations appropriate for your system If you need any assistance please call us on 01937 588 226 MuteClip Channel must not be installed over any opening or vent in your wall or ceiling system To overcome this install a MuteClip an...

Page 8: ...lt the MuteClips directly into the concrete ceiling at the appropriate centres See configurations or contact iKoustic for appropriate dimensions Attach MuteClip Channels into MuteClips MuteClip Channels should overlap by 200mm fix 4 self tapping screws into the shoulders of the channels to give a secure join MuteClip Channels should not overlap on a MuteClip Insert Acoustic Mineral Wool behind the...

Page 9: ...und to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your second layer of Acoustic Plasterboard and stagger the joins from the first layer making sure that the screws go into the MuteClip Channels Again leave a 2 5mm gap around the perimeter of the room Seal the perimeter and any other gap...

Page 10: ...igurations or contact iKoustic for appropriate dimensions The perimeter MuteClips must be no further than 100mm from the adjacent walls Screw MuteClips into the appropriate joists Attach MuteClip Channels into MuteClips channels must run perpendicular to the joists battens MuteClip Channels must overlap by 200mm fix 4 self tapping screws into the shoulders of the MuteClip Channels to give a secure...

Page 11: ...mm gap around the perimeter of the room Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your second layer of Acoustic Plasterboard and stagger the joins from the first layer making sure that the screws go into the...

Page 12: ...er MuteClips must be no further than 100mm from the adjacent walls Screw Clips into all the appropriate joists Attach MuteClip Channels into MuteClips channels must run perpendicular to the joists MuteClip Channels must overlap by 200mm fix 4 self tapping screws into the shoulders of the MuteClip Channels to give a secure join MuteClip Installation Guide Ceiling To Wooden Joist Ceiling MuteClip to...

Page 13: ...he perimeter of the room Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your second layer of Acoustic Plasterboard and stagger the joins from the first layer making sure that the screws go into the MuteClip Chann...

Page 14: ...est Yorkshire LS22 7DN Creating Quieter Spaces Together www iKoustic com 01937 588226 Sales ikoustic com 14 4 6 Square Please contact iKoustic to confirm correct configurations appropriate for your system If you need any assistance please call us on 01937 588 226 ...

Page 15: ...ct iKoustic for appropriate dimensions The perimeter MuteClip XP s must be no further than 100mm from the adjacent walls Screw MuteClip XP s into all the appropriate joists MuteClip XP s central track fixing should be no closer than 25mm from the bottom of the joist MuteClip XP Installation Guide Ceiling To Wooden Joist Ceiling MuteClip XP to Wooden Joist 1st Plasterboard to Channel 2nd Plasterboa...

Page 16: ...the MuteClip Channels Acoustic Plasterboard must not be in direct contact with any adjacent surfaces There must be a 2 5mm gap around the perimeter of the room Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Tecsound into manageable sized pieces for ease of installation Fix your ...

Page 17: ...t iKoustic for appropriate dimensions MuteClip LP s attach to the side of the joists The perimeter MuteClip LP s must be no further than 100mm from the adjacent walls Screw MuteClip LP s into the side of all the appropriate joists MuteClip LP s should be no closer than 25mm from the bottom of the joist MuteClip LP Installation Guide Ceiling To Wooden Joist Ceiling MuteClip LP to Wooden Joist 1st P...

Page 18: ...of the MuteClip LP s Fix your first layer of Acoustic Plasterboard to the MuteClip Channels Acoustic Plasterboard must not be in direct contact with any adjacent surfaces There must be a 2 5mm gap around the perimeter of the room Seal the perimeter and any other gaps with Acoustic Sealant Adhere Tecsound to the Acoustic Plasterboard using Tecsound s self adhesive backing It may be easier to cut Te...