iks aquastar midi
29
A possible application for the interval function with a random factor could, for
example, be the creation of currents and eddies. You could, for example, allocate an
interval with different times to each one of two sockets (pumps). Then, sometimes both
pumps would be on (active), sometimes only Pump 1, sometimes only Pump 2, and
sometimes both would be off (inactive). A further application could be the control of a
dosing pump (e.g.
iks Vario
). You could operate this pump, for example, for 1 second in
every hour and thus feed liquid fertiliser or trace elements into the water.
Programming:
Select the menu “Time functions” from the main menu and
confirm with
enter
.
Again with the arrow keys, you can select the funtion “Interval”.
Confirm with
enter
.
First select the number of the
interval function
(
not the
socket number
!). If an interval function hasn't ’been
programmed yet then your display will appear as on the left
here. Please press
enter
.
You can now select ‘‘
On
‘‘ or ‘‘
Off
‘‘ with the arrow keys. If you
want to delete an interval function, select ‘‘
Off
‘‘. If you want ot
programme an interval, select ‘‘
On
‘‘. Confirm with
enter
.
Now you can determine the period in which the interval function
is to be active. Firstly, enter the time you want this function to
start. Confirm with
enter
.
Now enter the time the interval function is to cease and confirm
with
enter
. In the adjacent example, the interval is active from
10 am to 12:00 noon.
Now enter how long the interval is to be on for (socket ‘live’)
and confirm with
enter
.
This display only appears in the “
Professional
” programming
mode. You can add a random factor to the previously entered
“On”-time (socket ‘live’). Confirm with
enter
.
Now enter how long the interval is to be off for (socket without
current) and confirm with
enter
.
This display only appears in the “
Professional
” programming
mode. You can add a random factor to the previously entered
“Off”-time (socket without current). Confirm with
enter
.
Main menu 13
Time functions <>
Time functions 31
Interval <>
Interval 3P
No: 01 S(--) <>
Interval 3Q
On <>
Begin 3R
10:00:00 <>
End
3S
12:00:00
How long on? 3U
00:02:00
RandomFacOn?3V
00:01:00
How long off? 3W
00:02:00
RandomFacOff
?
3X
00:01:00