iks aquastar midi
35
7.6.5.1 Current
If you have selected ‘‘Current‘‘, the following dialogue will appear:
Now you can specify whether you want to create waves (“Yes‘‘)
or not (‘‘No‘‘). If you have selected ‘‘No‘‘, you can skip the next
step (wave duration). Confirm with
enter
.
Now you can enter the wave duration. In the adjacent example
this is 5 seconds. Confirm with
enter
.
This and the next display
only
appear in the
professional
programming level! Now you can specify whether you want to
produce a nocturnal fall in values (‘‘Yes‘‘) or not (‘‘No‘‘). If you
have selected ‘‘No‘‘, you can skip the next step (Fall of).
Confirm with
enter
. If you have selected ‘‘Yes‘‘, you can now
specify by what percentage you want to lower the values.
Now enter the desired value. Please observe that, for example,
you enter 010 for 10%. Confirm with
enter
.
Now another socket is to be allocated to this function. This is
selected with the arrow keys. In the adjacent example it's the
socket 07. The display “(--)” shows that no further function has
been allocated to this socket. The socket can then be selected
by pressing
enter.
If you’re dealing with a
variable-output
socket you can first of
all enter the output of the socket for the period the interval
function is active. Please observe the restrictions regarding the
systems that can be connected (Section 4.3.2 e.g.
no HQI- or
HQL lighting
!) It’s best to connect the appliances now (e.g.
pump, lamp) to the appropriate socket. Enter, for example,
‘80%’ by entering
zero, eight, zero
(not
eight, zero
, as this
would mean 800%!). Now press the
del
key. The socket or the
appliance will now be supplied with the appropriate current. If
the results are not quite what you wanted then you can enter
another value and test it with
del
. Repeat this procedure as
often as you want until the setting suits you requirements. You
would normally enter 100% here. Confirm your input with
enter
.
Now you can enter the socket output for “off” state. The
procedure for this is the same as before with ‘‘(On)‘‘. Make sure
you use the
del
key’s special function then confirm with
enter
.
Now use the arrow keys to select another time function or use
enter
to programme a further day/night simulation. Press the
Esc-key
to return to the main menu level.
Example:
On the basis of the values programmed above, the pump on Socket 07 would operate
alternately at 80% for 2 seconds and at 50% for 2 seconds (pulsating). The transition
between the two levels does of course not occur abruptly but gently. At night, this process
Waves 34
yes
<>
Wave duration 35
00:00:05
NocturnalFall 36
Ja
<>
Fall of
37
010 %
<>
Which socket? 29
No: 07 (--) <>
CntrlblSocket 2A
080% (On) del
CntrlblSocket 2A
050% (Off) del
Time functions 31
Current simul. <>